Page 5

Chapter Objectives

Read this chapter to familiarize yourself with the rest of the manual. You will learn about: • contents of this manual • conventions used in this manual • intended audience • related publications • technical support

Contents of this Manual

The following table describes the contents of this manual. Chapter

Title

Contents

Preface

Describes the purpose, background, and scope of this manual. Also specifies the audience for whom this manual is intended.

1

Introduction to StrataScan Bar Code Readers

Provides an introduction for the use of the StrataScan Bar Code Readers.

2

Hardware Features

Provides an overview of the readers and interface boxes. Includes a description of accessory items.

3

Designing Your System

Gives specific criteria for setup, symbols, symbol orientation and head range.

4

Installing Your Hardware

Describes how to connect your system hardware.

5

Maintenance and Troubleshooting

Describes how to maintain and troubleshoot your system hardware.

Appendix A

Specifications

Provides physical, electrical, environmental, and functional specifications for the readers and interface boxes.

Appendix B

Cable Pinouts

Lists the cable pinouts.

Appendix C

European Union Directives

Provides requirements for readers when used within the European Union.

Publication 2755-6.13

Page 6

P–2

Preface

Conventions Used in this Manual

The following conventions are used throughout this manual. • Bulleted lists such as this one provide information, not procedural steps. • Numbered lists provide sequential steps. • Italic type is used for emphasis. • Text within square brackets in this font represent the keys you press.

Intended Audience

No special knowledge is required to understand this document or use the StrataScan Bar Code Readers (Catalog Nos. 2755-LHR-5B, 2755-LHR-3C, 2755-LHR-5C and 2755-LHR-5BX1).

! Related Publication

ATTENTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.

The following table lists an additional publication related to the StrataScan Bar Code Readers. Publication Number

Technical Support Services

Publication 2755-6.13

Title

2755-6.14

StrataSet Programming Software Programming Guide

2755-921

Bar Code Basics

If you have any questions about the StrataScan Bar Code Reader, please consult this manual first. If you can’t find the answer, contact your local Allen-Bradley support office or distributor.

Page 7

Introduction to StrataScan Bar Code Readers This chapter can help you to get started using the StrataScan Bar Code Readers. We base the procedures here on the assumption that you have an understanding of bar code readers and control equipment. Because it is an introduction, this chapter does not contain detailed explanations about the procedures listed. It does, however, reference other chapters in this book where you can get more information. If you have any questions or are unfamiliar with the terms used or concepts presented in the procedural steps, always read the referenced chapters and other recommended documentation before trying to apply the information. This chapter tells you: • what tools and equipment you need • procedures for getting your system up and running

Required Tools and Equipment

Have the following tools and equipment ready: • screwdriver • drill • tape measure • personal computer with StrataScan software

Publication 2755-6.13

Page 8

1–2

Introduction to StrataScan Bar Code Readers

Procedures 1.

Check the contents of shipping boxes.

Reference

Unpack the shipping boxes while making sure that the contents include:

Chapter 4 (Installing Your Hardware)

• • • • • • •

StrataScan Holographic reader (Catalog No. 2755–LHR–5B, –3C, –5C or 5BX1) Mounting bracket (Catalog No. 77126–898–01 or –02) Power supply (12V dc) (Catalog No. 77126–896–01) Disk-based Hardware User Manual (Catalog No. 2755–6.13-DISK) StrataScan Bar Code Readers Instruction Sheet, Pub. No. 2755–5.16 On-line Programming Guide (Catalog No. 2755–6.14-DISK) included with Programming software Self–Mailer [Catalog No. 41062–002–01(A)]

If the contents are incomplete, call your local Allen-Bradley representative for assistance.

2.

Design the system.

Each application must be evaluated carefully. Successful bar code scanning begins with quality bar code symbols and the correct number, type, and location of readers, decoders, and package sensors. Refer to the following when designing your system.

• •

Publication 2755-6.13

Position the reader at a distance from the symbol that is within the range specified. A read rate test should be made to verify the range, and also to ensure optimum scanning and decoding. If a package sensor is used, position it so it can sense the package before the symbol reaches the scan area.

Reference

Chapter 3 (Designing Your System)

Page 9

Introduction to StrataScan Bar Code Readers

3.

Install the reader.

1–3

Reference

Mount the reader(s) (Catalog Nos. 2755-LHR–3C, 2755-LHR–5C, 2755-LHR–5B, 2755-LHR–5BX1) to the mounting bracket(s) (Catalog No. 77126–898–01 or 77126–898–02).

Chapter 4 (Installing Your Hardware)

Mounting Bracket

Reader

Make sure placement of the mounting bracket allows you to connect the reader to the interface box (Catalog No. 2755-LHB–1). Skip this information and step #4 if you are not using an interface box. The standard cable (Catalog No. 2755–LHC–2) from the interface box to the reader is 10 ft. long (3.05 m). Interface Box To interface box (8–pin connector)

To 15-pin connector Reader

Publication 2755-6.13

Page 10

1–4

Introduction to StrataScan Bar Code Readers

4.

Install the interface box.

Reference

Mount the interface box to your mounting surface after having attached the sensor/relay leads to the sensor terminal block inside the interface box. Make sure that the 3 power leads from the interface box power cord are connected to their correct locations on the power terminal block and grounding posts terminals inside the interface box case.

Screw Holes

Interface Box

Screw Holes

Sensor Terminal Block

Power Terminal Block Interface Box Grounding posts

Power Cable

Sensor Cable

To Power Receptacle Sensor housing

Publication 2755-6.13

Chapter 4 (Installing Your Hardware)

Page 11

Introduction to StrataScan Bar Code Readers

5.

Install the power supply.

Reference

Place the power supply (Catalog No. 77126–896–01) within 12 ft. (3.66 m) of the scanner.

6.

1–5

Chapter 4 (Installing Your Hardware)

Connect the hardware components together.

Reference

Chapter 4 (Installing Your Hardware)

If you are using an interface box, connect the reader, power supply and package detect to the interface box. If you are not using an interface box, connect the reader to the host device and power supply.

Power Supply

To Power Receptacle

Grounding Pin To Reader (9-pin connector)

To Reader (25-pin connector) To PC (9-pin connector) Reader

7.

Apply power to the reader system.

After all your hardware components are installed and connected, apply power to the interface box first, then your reader system.

Reference

Chapter 4 (Installing Your Hardware)

Publication 2755-6.13

Page 12

1–6

Introduction to StrataScan Bar Code Readers

8.

Check the reader defaults, program as needed.

Make sure you have DOS or Windows–based software on your personal computer. Run StrataSet Programming software, Catalog No. 2755–LHS–1. Make sure that communications has been established with your reader. e.g., read a test bar code to verify that the default settings are correct (i.e., the reader is communicating with the configuration device). Program as needed.

9.

Change configuration settings as necessary.

If you need to set the reader to other than the default settings, refer to the software manual. Exit Program mode and place the reader in Run mode.

Publication 2755-6.13

10.

Connect the system to host.

11.

Run your application.

Reference