Page 37

Chapter

5

A–B

General Setup Parameters Chapter Objectives

This chapter describes parameters specific to the operation of the scanner including:

• System Status • Power Consumption • Beeper Operation • Capture Count • Spotter Beam • Autosense Mode To set specific operating parameters, scan the appropriate bar code labels in each section. Note: Throughout this chapter, default settings for parameters are flagged by an asterisk (* ).

System Status

The labels in this section allow you to examine the configuration of your system. To send a list of currently programmed parameters to the display device, scan option ZB. A sample display is shown on the top of the next page. Note: Scanning ZB may interfere with your terminal software, depending on your application.

ZB

Display Configuration

5–1

Page 38

Chapter 5 General Setup Parameters

Display Configuration Example (ZB Command) Power Always On Data Bits 7 Char Delay 00 Scanner ID None Preamble None Code ID Char No Serial Buffr Full

Parameter 39 *Armed Yes ASCII No *Addendum – Xmit S/S No Check Ch No Send Sys # – Send Ck Ch – UPCE Expand – Limits 01–32

Model 5317 Beeper Loud Parity None Protocol Off Prefix Off Postamble None Labels Full Display Duplex Half

UPC

Symbology EAN I 2/5

Yes – No – – Yes Yes No –

No No – – No – – – – No Yes – Yes – – – – 02–32

S 2/5

128

No Yes – – – – – – – – – – – – – – 04–32 01–32

Version 2.51 Baud Rate 9600 Stop Bits 1 RTS Rcv Rdy+ Suffix Off * Redundant Scan No Label Delay 00 Auto Label Bfr Off

Codabr No – – No – – – – 01–32

* Redundant Scan=Capture Count, Armed=Enabled, Addendum=Supplements Shaded parameters are not supported in this product.

Scan option ZC to send the program version number followed by carriage return-line feed (CR-LF) to the display device. The version number is sent in the form ##.## (1.00, for example).

ZC

Transmit Version Number

Scan option @C to send an identification code which verifies the specific program type of the scanner to the display device.

@C

Transmit Program ID

Note: Options ZC and @C are used for troubleshooting to identify the scanner. 5–2

Page 39

Chapter 5 General Setup Parameters

Power Consumption

You can select one of two power consumption modes for the scanner. Option @A supplies full power to the scanner at all times. Option @B allows the scanner to revert to standby mode after a successful read. This mode is a power conservation feature whereby the scanner uses extremely low power (microwatts) from the host terminal. To supply full power to the scanner at all times, scan label @A.

@A

Enable Continuous Full Power *

Note: The scanner automatically uses full power when configured to operate in Autosense mode. To allow the scanner to revert to standby mode after a successful read, scan label @B.

@B

Enable Standby Power

5–3

Page 40

Chapter 5 General Setup Parameters

Beeper Operation

5–4

To disable or set the volume of the beeper, scan the appropriate option below.

AA

Beeper Off

AB

Beeper On; Volume Low

AC

Beeper On; Volume Medium

AD

Beeper On; Volume Loud *

Page 41

Chapter 5 General Setup Parameters

Capture Count

Capture Count determines the number of successful, identical decodes that must occur for a valid read. You can use the capture count to enhance the security of the bar code reader. Option BC sets the capture count to 1 which requires one successful decode.

BC

Capture Count = 1 *

Scan option BD to set the capture count to 2. Two identical decodes must occur for a valid read.

BD

Capture Count = 2

Because the laser scans a label many times a second, you will notice little or no change in the speed of the decode.

5–5

Page 42

Chapter 5 General Setup Parameters

Spotter Beam

You can enable the scanner to use a spotter beam which helps when aiming the scanner. Each time you press the trigger, the scanner generates a bright laser spot for a fixed duration, after which the scanner beam is activated. The spotter beam is recommended for long range applications. Scanning label NP disables the spotter beam. Hold the trigger for two seconds after scanning.

Disable Spotter Beam *

NP

To enable the spotter beam, scan label NQ, then scan a digit from 0 – 9 (Appendix B), holding the trigger for two seconds after scanning the digit. Each digit enables the spotter beam for a specified duration as shown in the table below. For example, to enable the spotter beam for 200 milliseconds, scan the NQ label, then scan code 3 in Appendix B. NQ

+ Enable Spotter Beam=xx msec

This Digit 0 1 2 3 4 5 6 7 8 9

Enables Spotter Beam for: 50 ms 100 ms 150 ms 200 ms 250 ms 300 ms 350 ms 400 ms 450 ms 500 ms

Note: Spotter Beam and Autosense Mode are mutually exclusive parameters. Only one of these parameters can be enabled at a time. 5–6

Page 43

Chapter 5 General Setup Parameters

Autosense Mode

In Autosense mode, the scanner has an internal object sensor allowing you to operate the scanner in an optional Autostand (Catalog No. 2755-NS2) for hands-free operation. When the scanner is placed in the Autostand it becomes immediately active for reading any bar code label presented to it. The scanner is triggered when a bar code label breaks the scan beam path between the reflective label on the stand and the scanner. To activate Autosense mode, scan the Enable Autostand (NO) label. You must hold the trigger down for two seconds after scanning the label.

NO

Enable Autosense Mode

The scanner will respond by emitting a continuous, low level, red beam of light. Note: The scanner is automatically configured to use full power (not standby power) in Autosense mode. For details on how to set up the scanner to operate in the optional Autostand, see Appendix C. To deactivate Autosense mode, scan the Disable Autostand symbol (NN). You must hold the trigger down for two seconds after scanning the label.

NN

Disable Autosense Mode *

Note: Spotter Beam and Autosense Mode are mutually exclusive parameters. Only one of these parameters can be enabled at a time. 5–7