Setup Instructions Chapter Objectives
This chapter provides setup instructions including:
Installing Wedge Interface
Figure 4.1 shows the basic connections for installing the scanner as a keyboard wedge interface. The installation uses two cables: the scanner interface cable and the wedge interface cable. Cables for the different terminal types are listed in Table 2.A.
• Installing the Wedge Interface • Enabling Wedge Mode • Selecting Terminal Type • Scanner Configuration Guidelines • Scanner Default Settings
Figure 4.1 Keyboard Wedge Interface Connections Optional Power Supply 1 Catalog No. 2755-PW1 AC Power Source
Power Supply Receptacle
Computer or Terminal
Wedge Interface Cable
1
Scanner 2755-G3-W or 2755-G6-W
Optional power supply required for DEC terminals.
4–1
Page 26
Chapter 4 Setup Instructions
Connecting Scanner Interface Cable The scanner interface cable has a modular plug (resembling a telephone connector) on one end and a DB9 squeeze-to-release connector on the other end. To install the interface cable: Insert the modular plug into the opening at the bottom of the scanner’s handle (Figure 4.2). The modular plug is keyed to insure proper insertion. Press firmly until the plug clicks into place. Figure 4.2 Connecting Scanner Interface Cable
4–2
Page 27
Chapter 4 Setup Instructions
Removing Scanner Interface Cable At some point you may have to replace the interface cable with another cable. CAUTION:
!
Do not remove the scanner interface cable until the host computer/terminal is turned off. Failure to do this could result in damage to the scanner.
To remove the interface cable, follow these steps. 1. Turn power to computer/terminal off. 2. Disconnect optional power supply from AC power source. 3. Disconnect scanner from wedge interface cable. 4. Insert a straightened paper clip into the cable release hole as shown in Figure 4.3. 5. Press down firmly on the paper clip to release the retainer and gently pull the connector out of the scanner. Figure 4.3 Removing Interface Cable
Cable Release Hole
4–3
Page 28
Chapter 4 Setup Instructions
Connecting Wedge Interface Cable The wedge interface cable connects the scanner to the terminal keyboard and the terminal. You select a wedge interface cable based on the the terminal you are using. The available cables are listed in Table 2.A. The wedge interface cable has a connector housing and a ”Y” cable. The housing contains 1 or 2 plug-in sockets for the scanner and an optional power supply. The two legs of the ”Y” cable connect to the terminal keyboard and the terminal. CAUTION:
!
Do not connect scanner to terminal until power to the terminal is off. Failure to do this could result in damage to the scanner.
To connect the wedge interface cable: 1. Turn off power to the computer/terminal to which the scanner will be connected. 2. Plug the DB9 squeeze-to-release connector of the scanner interface cable into the connector housing of the wedge interface cable. 3. Unplug the keyboard from the terminal and replug the keyboard into the short leg of the ”Y” cable. 4. Plug the remaining long leg of the ”Y” cable into the terminal where the keyboard was connected. 5. Arrange the fully connected unit so that all cables run freely.
4–4
Page 29
Chapter 4 Setup Instructions
Connecting Optional Power Supply Some terminal interfaces require an external power supply. One end connects to a standard AC receptacle supplying the appropriate voltage level. The other end plugs into a receptacle located on the housing connector of the wedge interface cable. CAUTION:
!
The Catalog No. 2755-PW1 Power Supply has the following polarity: +5 V + Ground If using another power supply, the polarity must be the same.
To install the power supply: 1. Power to the terminal must be turned off.
CAUTION:
!
Do not connect power supply until the terminal is turned off. Failure to follow this caution could result in damage to the scanner or terminal.
2. Plug the circular connector of the power supply into the receptacle on the housing connector of the wedge interface cable. 3. Plug the power supply into a standard AC power source.
Terminal Power Up Sequence Turn on the power to the terminal to which the scanner is connected. The unit will issue a series of beeps which are intentional and indicate that the terminal/keyboard power-on reset routines have been completed. 4–5
Page 30
Chapter 4 Setup Instructions
Enabling Wedge Mode
After installing the keyboard wedge interface you need to enable the scanner to operate in wedge mode. If this is a first time installation you must enable the scanner to operate in wedge mode. To enable wedge mode, scan label CE and listen for two short beeps.
CE
Selecting a Terminal Type
Enable Wedge Mode *
You now need to identify the type of terminal that the wedge interface is connected to. Scan the appropriate label below and listen for two short beeps. First time installations require you to program the scanner for use with the connected terminal.
1 2
4–6
CF
PC-AT * PS/2 and 50/60/80 Allen-Bradley 6121 Allen-Bradley 1784-T50, -T60 Allen-Bradley 2706-DL40 1 Allen-Bradley 1784-T35 (AT mode) 2 Compaq 386, 286
CG
PC-XT Allen-Bradley 6120, 2706-DL401 Allen-Bradley 1784-T35 (XT mode) 2 Compaq Deskpro
Can be used in AT or XT mode depending on the internal jumper. See DL40 User Manual. Can be used in AT or XT mode depending on the DIP switch setting. See User Manual for 1784-T35.
Page 31
Chapter 4 Setup Instructions
CH
CI
IBM 3151, 3472
DEC VT220 VT240, VT320, VT340, VT420, VT1000
You have now completed the process of installing and configuring the scanner to operate in wedge mode. The rest of the manual covers additional parameters that can be set for the scanner and your application. Review the configuration guidelines and factory default settings in the following sections to determine if changes are required.
4–7
Page 32
Chapter 4 Setup Instructions
Scanner Configuration Guidelines
Configuration is the process of enabling or disabling certain scanner operating parameters. The host computer/terminal and the types of bar codes that will be encountered will determine which parameters should be enabled or disabled. Follow three basic steps to configure your scanner: 1. Review the rest of the manual to familiarize yourself with each group of scanner parameters. 2. Review the requirements of your application This will enable you to determine if the factory defaults must be changed. 3. Enable or disable the relevant parameters by scanning the bar codes in Chapters 4 through 7. The section that follows describes this process. All configuration bar code labels in this manual are Code 128, Character Set B. Scanning Menu Labels The scanner does not have a distinct configuration mode. Instead, it automatically recognizes and reacts to labels you scan. You do not scan an enter or exit label to begin or exit configuration mode. Most parameters are set by scanning one label. For example, assume your application uses Codabar labels. By default, this symbology is disabled. To select the Codabar symbology, locate the Codabar menu in Chapter 7 and scan the label to the left of Enable Codabar. The correct label is shown below.
VB
Enable Codabar
A successful scan is indicated by two short-high beeps. An unsuccessful scan produces no beeps and requires you to rescan the Codabar label. Most parameters are modified in this way. When you are finished with modifications you can resume normal bar code scanning. 4–8
Page 33
Chapter 4 Setup Instructions
Note: When enabling or disabling a parameter, be sure the scanner beam illuminates only one symbol at a time. The layout of this manual minimizes the accidental scanning of multiple labels. Some parameters require that you scan multiple labels to modify a setting. An example is the Intercharacter Delay parameter. To set the intercharacter delay to 5 milliseconds (msec): 1. Scan the Intercharacter Delay (GB) label and listen for one short beep.
GB
+ Intercharacter Delay=xx msec
The dotted boxes to the right of the label indicate that you must scan two additional labels; one for the digit 0 and the second for the digit 5. 2. After the beep, scan the bar code beside 0 in Appendix B, and listen for one short-high beep. 3. Scan the bar code beside 5 in Appendix B and listen for two short beeps. The two beeps indicate that you scanned the last parameter argument. If you scan the Intercharacter Delay (GB) label and then scan a normal data label (instead of 0 and 5), a normal tone is emitted in response to the data label, and the programming command is ignored. No exit code is required to resume normal operations. Note: Any parameter that requires multiple scans will display dotted boxes to the right of the primary label. The number of dotted boxes indicates the number of additional labels to be scanned.
4–9
Page 34
Chapter 4 Setup Instructions
Scanner Default Settings
Table 4.A lists the factory default settings for each group of scanner parameters. Table 4.A Scanner Default Settings
Parameter Wedge Mode Terminal Type
Parameter Power Consumption Beeper Operation
Capture Count Spotter Beam Autosense Mode
4–10
Keyboard Wedge Options Default Enable or Disable Enable PC-AT, PS/2, 50/60/80 PC-AT, PS/2, 50/60/80 PC-XT IBM 3151 DEC VT220
General Scanner Setup Options Default Enable Continuous Full Power Continuous Full Power Enable Standby Beeper Off Beeper On; Volume Loud Beeper On; Volume Low Beeper On; Volume Medium Beeper On; Volume Loud 1 or 2 1 Enable or Disable Disable Enable or Disable Disable
Page 35
Chapter 4 Setup Instructions
Table 4.A (continued) Scanner Default Settings
Parameter Prefix Suffix Scanner Identifier Code Identifier Preamble Postamble Intercharacter Delay
Code Code 39
UPC (A and E)
Message Format Options None, STX, or SOH None, ETX, CR, LF, HT, or CR and LF Disable or a number (01- 99) Disable or Enable None or 1-4 characters None or 1-4 characters User Defined Delay (in msec) or No Intercharacter Delay
Default None None Disable Disable None None No Intercharacter Delay
Symbologies Options Disable Enable Standard Code 39 Enable Full ASCII Code 39
Default Enable Standard Code 39
Enable or Disable Modulo 43 Check Character Enable or Disable Transmission of Start/Stop Character Minimum Length Maximum Length Disable Enable with 2 or 5 digit supplements Enable without 2 or 5 Digit Supplements
Disable
Enable/Disable Expanded UPC-E Enable/Disable Transmission of Number System Chararacter Enable/Disable Transmission of Check Digit Enable/Disable UPC to EAN Translation
Disable Enable
Disable 1 32 Enable without 2 or 5 Digit Supplements
Enable Disable
4–11
Page 36
Chapter 4 Setup Instructions
Table 4.A (continued) Scanner Default Settings Code EAN/JAN (8 or 13 digit)
Interleaved 2 of 5
Standard 2 of 5
Code 128
Codabar
Resetting Factory Defaults
Symbologies Options Disable Enable with 2 or 5 Digit Supplements Enable without 2 or 5 Digit Supplements
Default Disable
Enable or Disable Transmission Number System Chararacter Enable or Disable Transmission of Check Digit Disable Enable without Check Digit Enable with Check Digit
Enable
Minimum Length Maximum Length Enable or Disable Minimum Length Maximum Length Enable or Disable Minimum Length Maximum Length Enable or Disable Enable or Disable Transmission Number System Chararacter Minimum Length Maximum Length
2 32 Disable 4 32 Enable 1 32 Disable Disable
Enable Disable
1 32
To reset the scanner to the factory default settings (listed in Table 4.A) scan label ZA.
ZA
Reset to Factory Defaults
Note: Scanning this label produces a bi-level tone. 4–12