Page 31
CHAPTER 3
RFID TAG READER
Geiger Tag Utility The Geiger Tag utility is designed to assist you in finding the location of a particular tag, or one of a group of tags. It does this by measuring the returning signal strength (RSSI) from the tag, and displaying this information on the screen, along with an audible queue. As you scan the reader near a tag, the RSSI increases, and you see and hear the change. In order to help narrow the field of view of the reader as you zero-in on the tag, the reader’s output power is scaled down as you get closer to the tag. To start the Geiger Tag search, either hold the pistol-grip trigger button, or click once on the green Start Search button. The reader continues to read tags until you release the trigger or click the Stop button. Click the red Close box at the top-right corner to return to the main screen.
The Geiger shows the tag’s signal strength and the reader’s current output power. Use the Start Search button (or pistol-grip trigger) to start the search.
When a tag is read, its EPC is displayed on the screen, along with graphical and numeric readouts of the tag’s return signal strength, and the reader’s transmitting power.
Having the Geiger react to every tag it sees can quickly become overwhelming. Use the yellow Mask button at the top-left corner to indicate which tag or tags you are interested in finding (see the Tag Mask section). Narrowing the search down with a tag mask can make the Geiger utility much more effective.
ALH-900X USER’S GUIDE DOC. CONTROL #8102114-000 REV C
27
Page 32
RFID TAG READER
CHAPTER 3
Tag Access Utility The Tag Access utility allows you to read from and write to specific portions of a tag’s memory. The utility is divided up into two separate tabs: the Basic tab and the Advanced tab. The Basic tab gives a quick overview of the tag’s memory layout, and gives you basic ability to write new data to the tag. The Advanced tab gives full access (bank, start pointer, and length) over the low-level writing and reading operations, as well as controls for locking and unlocking specific portions of tag memory. EPC Gen2 tag memory is divided up into four distinct banks: Reserved, EPC, TID, and User. The Reserved bank contains the tag’s Access password and Kill password (each two words long), though all tags may not support both passwords. The EPC bank contains the tag’s “id” – its EPC code – along with some other information related to the EPC. The TID bank is generally read-only, and contains information about the tag’s manufacturer, model, and basic capabilities. Alien Higgs tags contain bits in the TID bank that are guaranteed to be unique from one tag to the next. The User bank may not be present in all tag types, and when it is supported each tag provides different amounts of memory there.
Basic Access Tab The Basic Access tab has text fields for each of the separate fields of tag memory. Clicking the Read All button (or pulling the pistol-grip trigger) causes the reader to try and read all of the data for each of the fields, from whatever tag is in the field. The separate fields fill in, one-by-one, as the data is read. Since there is no definitive way of knowing how much User memory a tag has, the reader simply reads the User data two words (32 bits) at a time, until a failure occurs.
The Basic Access tab gives a visual overview of all of the fields in tag memory.
28
Pressing the Read All button (or pulling the pistol-grip trigger) fills in each memory field with data from the tag.
ALH-900X USER’S GUIDE DOC. CONTROL #8102114-000 REV C
Page 33
CHAPTER 3
Pressing the small green buttons labeling each memory field will cause the reader to only read data from that field.
RFID TAG READER
Pressing the red “write” buttons cause the reader to write the shown data to the tag. You can edit the data in the field before writing it to the tag. The field turns orange while writing, and then turns white or red, depending on the success of the write operation.
When there are many tags in the field, the Basic Access tab can have difficulty reading all of the data from the same tag when you click the Read All button. To make sure that you are accessing the same tag throughout the operation, you should set a tag mask, using the yellow Mask button at the top-left corner of the screen. Also, when the tag has some of its memory fields locked with an access password, you must provide that same password as part of the access operation in order for it to succeed. You use the violet Pwd button at the top-right corner to do this.
The yellow Mask button lets you restrict the reader to only access one tag at a time.
ALH-900X USER’S GUIDE DOC. CONTROL #8102114-000 REV C
The violet Pwd button opens up a dialog window where you can enter in an Access Password, for accessing tag memory that may have been locked.
29
Page 34
RFID TAG READER
CHAPTER 3
Advanced Access Tab The Advanced Access tab has three general control areas: Read, Write, and Lock. All three operations require you to specify the bank of tag memory to access (Reserved, EPC, TID, and User). When reading and writing, you must specify the offset into that bank of memory where you would like to access. The reading operation also requires you to specify the length of the data to read. Both the offset and length parameters are measured in words (1 word = 2 bytes = 16 bits).
30
Three main areas in Advanced Access: Read, Write, and Lock. Each requires you to specify a memory bank.
Note in this read that the tag’s actual EPC code (FEEDFACEBEEF…) is two words offset into the EPC bank.
You must enter the hex data to write in the field. The helpful popup keypad makes entering hex data easy.
Verifying the success of the write, with another read (of just the EPC code). Now FEEDFACEDEADBEEF…
ALH-900X USER’S GUIDE DOC. CONTROL #8102114-000 REV C
Page 35
CHAPTER 3
RFID TAG READER
When locking, you have the option of locking the Access Password and Kill Password (both in the Reserved bank) separately, so the Lock command has a list of tag memory fields instead of banks. The other parameter is the type of lock: Lock, Unlock, PermaLock, and PermaUnlock. All locking operations require you to confirm by clicking OK to an alert message. The “Perma” options are, well, permanent, so use caution. Locking a field doesn’t immediately protect it until you also write a non-zero Access Password to the tag (and you should probably lock that field as well!). Please refer to the EPC Gen2 Protocol Specification for complete details on how the various locking operations affect the tag’s behavior.
You must enter the hex data to write in the field. The helpful popup keypad makes entering hex data easy.
Verifying the success of the write, with another read (of just the EPC code). Now FEEDFACEDEADBEEF…
As on the Basic Access tab, you have full access to the tag Mask and current Access Password in this tab. On this screen, the read operation failed for two reasons: the mask doesn’t match the tag’s new EPC (FEEDFACEDEADBEEF…) and we’re trying to access it with an incorrect Access Password.
ALH-900X USER’S GUIDE DOC. CONTROL #8102114-000 REV C
31
Page 36
RFID TAG READER
CHAPTER 3
Tag Mask When the application first launches, it is configured to look for and report every tag it sees. You don’t always want to read every tag – perhaps you are searching for only one class of product, or are trying to access one particular tag in order to write data to it. The Gen 2 protocol provides for something called a select mask - a filter definition that is broadcast to all of the tags in the field before each operation, that specifies which tags are allowed to participate in that operation. The ALH-900x demo software allows you to specify a tag mask, which is used transparently in each of the utility screens. The current mask is displayed at the top of each screen in yellow text, alongside the Mask button that brings up the Tag Mask whenever it is clicked.
At its heart, a tag mask defines a piece of data that must match exactly a specific portion of the tag’s memory. This includes the memory bank (not just the EPC bank), a pointer offset into that bank, and the actual hex data to match against. In reality, you don’t always want to have to think about memory banks and pointer offsets – you just want to find that pair of jeans that is on the wrong rack, or you only care about “pallet tags”, however that is defined for you. The Tag Mask screen therefore gives you three ways to pick a tag mask: 1. Scanning the field and picking a tag from a list. 2. Exactly defining the bank, offset, and hex data. 3. Picking a named mask from a preset list Once you have defined and set your mask, just close the Tag Mask window and your new mask will be displayed at the top of the screen you were originally on, and it will be used in subsequent operations.
32
ALH-900X USER’S GUIDE DOC. CONTROL #8102114-000 REV C
Page 37
CHAPTER 3
RFID TAG READER
Tag Mask – Scan
The Scan tab acts just like the Inventory screen – start/stop the reader with the trigger or Start Scan button, and all tags in range are displayed.
Select a tag from the list and click the Set Mask to Selected Tag button. Click an empty part of the list and click the Clear Mask button to clear the mask.
Masks defined with the Scan method are displayed on the utility screens as simply the full EPC of the tag.
Tag Mask – Specify The Tag Mask “Specify” tab allows you to do three things: take a quick peek at tag memory (to help you determine your mask definition), define an arbitrary or “EPC Prefix” mask, and verify your mask. The upper Quick Peek section lets you choose a bank, pointer offset, and number of words to read. Clicking the green Read button will query any tag in the field (without any masking) and report the data from that tag. The middle section is where you actually define your mask. There are two options here: create a mask based on an EPC prefix (i.e. “all tags starting with…”), or create an arbitrary mask. If you select EPC Prefix, the only thing you have to provide is the hex data representing the initial part of the EPC code for your tags (the other controls are disabled). If you select Arbitrary, you choose the bank and pointer offset, along with the mask data. Click the red Set Mask button to define your mask. After you’ve defined a mask, you can do a quick verification by clicking the green Masked Read button in the Verify Mask section at the bottom. Any responding tag’s EPC will be shown in the text field there.
ALH-900X USER’S GUIDE DOC. CONTROL #8102114-000 REV C
33
Page 38
RFID TAG READER
34
CHAPTER 3
The Quick Peek section lets you get a glimpse of an actual tag’s memory, to help you define your mask.
Defining a mask based on an EPC prefix is easy – just click the radio button, enter the EPC data and click Set Mask.
Defining an arbitrary mask requires you to specify the bank and offset, along with the data. This TID mask example selects all Alien Higgs3 tags.
Using the Verify Mask feature, you can make sure you’ve entered the mask correctly. Be sure to test tags that match as well as tags that don’t match.
Masks defined with the EPC Prefix method are displayed on the utility screens as that initial part of the EPC.
Masks defined with the Arbitrary method are displayed on the utility screens with the bank, offset, and data.
ALH-900X USER’S GUIDE DOC. CONTROL #8102114-000 REV C
Page 39
CHAPTER 3
RFID TAG READER
Tag Mask – Presets The third way to set a tag mask is with the Presets tab. This screen shows a list of pre-defined tag masks, such as “all tags”, “all Higgs3 tags”, etc. These presets are hard-coded in the application right now, but will be user-configurable in the future.
Masks chosen from the Presets tab are shown on the utility screens with the display name in the mask preset definition. Your mask presets might display “Blue Jeans” or “Pallet Tags” instead.
Pick one of the selections from the Presets list, and you can see the displayed name and mask definition. Click the Set Mask button to use it.
ALH-900X USER’S GUIDE DOC. CONTROL #8102114-000 REV C
35
Page 40
RFID TAG READER
CHAPTER 3
Reader Settings The Reader Settings screen allows you to see and change certain parameters of the RFID reader, such as transmit power, and some Gen2-specific parameters on the RFID tab. There is a second Network tab with some additional parameters related to the reader’s network interface and some common Alien features, such as a Heartbeat and TagStream functionality. To commit any changes made on the Reader Settings pages, you must click the OK button at the lower-right corner. Clicking the Cancel button or the Close (X) button in the top-right corner returns you to the main screen without applying any of the changes that you made.
The RFID tab has controls for RF Power and some Gen2 parameters, such as Session, Q, and Inventory Target.
36
The Network tab shows the reader’s MAC and IP addresses, as well as fields and checkbox controls for the Heartbeat server (for UDP-based discovery), and a TCP-based TagStream feature.
ALH-900X USER’S GUIDE DOC. CONTROL #8102114-000 REV C