Manual · Adtran
Total Access 1500 FT1 DP: Total Access 1500 Fractional T1 Data Port Installation and Maintenance
Manual18 pagesPDF 145 KB
Installation and maintenance guide for the ADTRAN Total Access 1500 FT1 DP fractional T1 data port card (P/N 1180405L1).
What this file really is
The old site listed this file as “Installation Manual” for the Adtran TA-1500. This is the installation guide for the Total Access 1500 FT1 DP plug-in card, not for the Total Access 1500 channel bank itself.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
The installation and maintenance practice for the ADTRAN Total Access 1500 FT1 DP (P/N 1180405L1), the central office card that plugs into a Total Access 1500 channel bank to deliver a fractional T1 circuit over one 2-wire pair using 2B1Q HDSL. It covers time slot assignment and installation, DIP switch and craft interface options, front panel LEDs and bantam jacks, DSL testing, the menu screens, loop deployment guidelines, maintenance, troubleshooting, specifications and the FT1 loopbacks.
Its parts
- General
- Installation
- Connections
- DSL System Testing
- Operation
- DSL Deployment Guidelines
- Maintenance
- Troubleshooting Procedures
- Product Specifications
- FT1 Loopbacks
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
This is the installation and maintenance guide for the ADTRAN Total Access 1500 FT1 DP (Fractional T1 Data Port), P/N 1180405L1, a card that plugs into a Total Access 1500 channel bank. It covers installing the card, setting its options, the LEDs and test jacks, the craft interface screens, DSL loop guidelines, troubleshooting, specifications and loopbacks.
- Device
- Central Office card that deploys a Fractional T1 circuit over 2-wire metallic facilities, P/N 1180405L1 p. 1
- Mounting
- Plugs into a standard Total Access 1500 channel bank and takes two slots; no installation wiring p. 1, 2
- Payload
- 2 to 12 DS0 channels (128 kbps to 768 kbps), set by the front panel rotary switch p. 2
- Loop interface
- 2B1Q, full duplex echo cancelling, one pair, 784 kbps, 135 Ω input impedance p. 14
- Power
- -48 VDC @ 125 mA with FNID; 215 mA with FNID and FT1 Repeater; 300 mA with a locally-powered FNID and two FT1 Repeaters p. 14
- Span power
- -190 VDC nominal, current limit at 125 mA ±5%, internally generated p. 14
- Companion units
- Works with FNIDs 1242041LX, 1242042LX and 1245201LX and FT1 Repeaters 1242050L2 and 1245211L1; full features with FT1 Repeater 1245211L1 and FNID 1245201L2 p. 2
- Options
- AMI or B8ZS line code, SF or ESF framing, latching loopback, 20-minute loopback time out, per-channel A/B signalling; set by DIP switches SW1 to SW3 or the SCU craft interface p. 3, 4
- Indicators
- Five front panel LEDs: STAT, DS1, DSL, SX (sealing current) and REM p. 5
- Test jacks
- DS0 bantam jacks for a Tele-Path Instruments 108/109 RT II test set at 64 kbps p. 6
- Loop limits
- Loop loss 36 dB maximum at 200 kHz; single bridged taps under 2 kft, total taps under 2.5 kft p. 14
- Loop length
- Non-loaded loops only; up to 9 kft on 26-AWG and 12 kft on 24-AWG cable, bridged taps included p. 12
- Dimensions
- 3.0 in. high, 1.25 in. wide, 9.5 in. deep, nominal p. 14
- Operating temperature
- -40°C to +70°C; storage -40°C to +85°C; humidity up to 95 percent noncondensing p. 14
What this manual walks you through
- Installing the card and how the shelf assigns its time slots p. 2
- Setting options with DIP switches or the craft interface p. 3, 4
- Reading the front panel LEDs p. 5
- Testing through the DS0 bantam jacks p. 6
- Using the craft interface status, performance, loopback and provisioning screens p. 8, 9, 10, 11
- Checking a loop against the DSL deployment guidelines p. 12
- Troubleshooting with the troubleshooting table p. 13
- Activating and releasing FT1 loopbacks with latching loopback codes p. 15, 16, 17, 18
Good to know
- The card takes contiguous time slots that must not already be assigned to other cards, and it does not wrap around past the last channel. p. 2
- Once a slot is provisioned through the craft interface, the card's DIP switches are ignored in that slot. p. 3
- The card can be damaged by static electricity and needs handling precautions. p. 2
- Field repairs are not recommended; defective units go back to ADTRAN CAPS. p. 12
- With the time out enabled, any loopback left up for 20 minutes is released. p. 18
Questions this manual answers
How many slots does the Total Access 1500 FT1 DP take?
Two slots in a standard Total Access 1500 shelf, with power and signaling supplied through the backplane. p. 5
What does a red DSL LED mean on the FT1 DP?
The FT1 DP and FNID are not synchronized. The manual says to check the loop against CSA guidelines, loop loss at 200 kHz (not over 36 dB) and noise. p. 5, 13
What data rates can the FT1 DP carry?
From 2 channels at 128 kbps up to 12 channels at 768 kbps, chosen with the rotary switch. p. 2
Which loopback code loops the FT1 DP toward the network?
The OCU DP latching loopback command N1010101, sent in the primary DS0; the Total Access 1500 craft interface can also start it. p. 15
Why do the FT1 DP LEDs light one after another after insertion?
The first FT1 DP in a shelf takes about 20 seconds to communicate with the shelf common cards, shown by the LEDs cycling bottom to top. p. 2
The whole text · 2 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file