Manual · Adtran
Adtran TA-1500 User Guide
Manual2 pagesPDF 214 KB
Both pages are below, each with its text.
Filed with · 1 model
Also filed with these models on the old site
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
This two-page job aid is for the ADTRAN Total Access 1500 FT1 DP, a Fractional T1 data port card (1180405L1) for the Total Access 1500 channel bank. It summarizes the status LEDs, rotary and DIP switch options, test jacks, turn-up steps, troubleshooting, testing and DSL loop guidelines.
- Device
- Total Access 1500 FT1 DP card, 1180405L1, installed in an ADTRAN Total Access 1500 channel bank p. 1, 2
- Bandwidth
- Rotary switch selects 2 to 12 DS0 time slots p. 1
- SW1 options
- SW1-1 AMI or B8ZS encoding; SW1-2 super frame or extended super frame; SW1-3 latching loopback; SW1-4 20-minute loopback time-out p. 1
- A/B signaling
- SW2-1-8 for channels 12 to 5 and SW3-1-4 for channels 4 to 1 p. 1
- Status LEDs
- STAT, DS1, DSL, SX and REM p. 1
- Test jacks
- Bantam jacks give near logic, intrusive access to the 1st DS0; a TPI 108/109 or equivalent test set can be used p. 1
- Loop loss
- Insertion loss should not exceed 36.0 dB at 200 kHz p. 2
- Loop length
- Non-loaded loops only; up to 9 kft on 26 AWG and 12 kft on 24 AWG, bridge taps included p. 2
- Bridge taps
- Any single bridge tap up to 2 kft; total bridge tap length up to 2.5 kft p. 2
- Loop noise
- Background noise about 31 dBrn or less and impulse noise about 50 dBrn or less, measured with a 50 kilobit filter p. 2
- Remote unit
- The FNID mounts in an ADTRAN T400 single mount stand alone housing or any standard T400 housing p. 2
- Craft access
- Loopbacks can be run from the FT1 DP loopback menu with a VT100 terminal or equivalent p. 2
What this manual walks you through
- Reading the status LEDs p. 1
- Setting the rotary switch and DIP switch options p. 1
- Turning up an FT1 circuit with the FNID p. 2
- Troubleshooting dark LEDs and loop sync failures p. 2
- Testing with loopbacks and the front panel test jacks p. 2
- Checking a loop against the deployment guidelines p. 2
Good to know
- The card must go in a shelf or mounting with a compatible frame ground on the edge finger connector. p. 2
- Voltages up to -200 VDC may be present on the telecommunications wiring. p. 2
- The card can be damaged by static electricity and needs handling precautions. p. 1
- The noise figures are approximations, offered as guidelines only, and vary between loops. p. 2
Questions this manual answers
How long does the TA 1500 FT1 DP take to sync with the FNID?
Allow about one minute; once DSL sync is reached the FT1 DP's DSL LED lights green. p. 2
What should I check if all FT1 DP front panel lights are off?
Check that the card is properly seated and that its power supply is good; if both pass, replace the FT1 DP. p. 2
What if the FT1 DP DSL LED stays red?
Check that the loop meets CSA guidelines, that loop loss at 200 kHz is not over 36 dB, and that noise is within limits; then try a known good unit. p. 2
What test set works with the FT1 DP test jacks?
A TPI 108/109 or equivalent, set for near logic, connected to the front panel test access jacks. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
JOBAID
TOTAL ACCESS ® 1500 FT1 DP TOTAL ACCESS 1500 FT1 DP CLEI: VAL2BB0A_ _
STATUS LEDs STAT ● Green
- Yellow ✷ Flashing Yellow DS1 ● Green
FT1 DP● Yellow1180405L1
6 7 8 9 10 5 11 4 12 3 2
TX RX● RedSTAT DS1 DSL
✷ Flashing Red DSL ● Green
SX● YellowREM● RedLOGIC SX
✷ Flashing Red
- OFF
- Green
REM ● OFF
- Green
Normal operation FT1 DP is in loopback FNID or repeater is in loopback Customer’s equipment is connected at the FNID and synchronized Yellow Alarm has been detected at the FNID’s Customer DS1 interface No signal detected at the FNID’s Customer DS1 interface, excessive Frame Bits Error/Loss of frame synchronization Error detected at the FNID’s DS1 interface FT1 DP is synchronized with the FNID or repeater and signal quality is good FT1 DP is synchronized with the FNID or repeater and signal quality is poor No synchronization with the FNID or repeater Error detected on loop No sealing current has been detected on the local loop Sealing current has been detected on the local loop FT1 DP is operating from hardware settings FT1 DP is operating from craft screen settings
ROTARY SWITCH
DIP SWITCH OPTIONS
The rotary switch is used to select the amount of bandwidth allocated via DS0 time slots.
SW1-1 Encoding Selects the type of T1 encoding used at the FNID’s DS1 interface
- Off, selects AMI encoding
- On, selects B8ZS encoding SW1-2 Framing Selects the type of T1 framing used at the FNID’s DS1 interface
- Off, selects super frame
- On, selects extended super frame SW1-3 Latching Loopback Enables/disables the ability to respond to latching loopbacks (i.e. OCU or NEI loopbacks)
- Off, disables the latching loopback feature
- On, enables the latching loopback feature SW1-4 Loopback Timeout Enables/disables the loopback time-out feature
- Off, disables the 20-minute time-out feature
- On, enables the 20-minute time-out feature SW2-1-8 A/B Signaling Enables/disables A/B robbed bit signaling for channels 12 - 5
- Off, disables A/B signaling
- On – enables A/B signaling SW3-1-4 A/B Signaling Enables/disables A/B robbed bit signaling for channels 4 - 1
- Off, disables A/B signaling
- On – enables A/B signaling
DS0s Selected
- Bandwidth (kHz)
- 2
12831924256532063847 8448 5129576106401170412768■Pin 35 Pin 15AMI987654321Channels 4 Through 110LBTOR, DSL Ring T, DSL Tip11LLBSW1, - 12ESF4SFB8ZSChannels 12 Through 53O O 1 N N2345678O O 1 N N234SW26 7 8 9 10 11 12 2
Provides DS0, near logic, intrusive test access to the 1st DS0 in the outbound data stream. Test sets such as a TPI 108/109 or equivalent can be used.
25 4 3BANTAM JACKSFT1 DP DSL CONNECTIONSO O 1 N N61180405L1-22A 0109
Note: Default settings in bold.
SW3
C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
- For a complete Installation and Maintenance Practice faxback: (877) 457-5007, Document #666. Please have your fax number available. ■
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
TOTAL ACCESS ® 1500 FT1 DP FT1 DEPLOYMENT CRITERIA Insertion loss should not exceed –36.0 dB at 200 kHz
LOOP INSERTION LOSS DATA Frequency Maximum (kHz): Loss Data (dB): 3k
–12.010k–15.0
Turnup Guide 1. Ensure that all of the DSL connections have been made between the FT1 DP and the FNID. 2. Install the FNID into an ADTRAN T400 single mount stand alone housing or equivalent. The FNID can be mounted in any standard T400 housing. 3. Install the FT1 DP into an ADTRAN Total Access 1500 channel bank. 4. After insertion of the FT1 DP, with the FNID installed at the remote location, its LEDs should illuminate momentarily before the FT1 DP attempts to start its training sequence, with the FNID. The FT1 DP’s SX LED should be illuminated. If it is not, refer to the Troubleshooting Guide in this document. 5. Allow approximately one minute for the FT1 DP to synchronize with the FNID. If DSL synchronization has been achieved, the FT1 DP’s DSL LED will be illuminated Green. If it is not, refer to the Troubleshooting Guide in this document.
50k–25.5Troubleshooting Guide100k–30.0150k–32.75200k–35.25
All FT1 DP Front Panel Indicators are Off
- Verify that the FT1 DP is properly seated in the shelf.
- Make sure power supply feeding the FT1 DP is good.
- If both of the above conditions pass, replace the FT1 DP.
DEPLOYMENT GUIDELINES Loops should be designed to comply with CSA guidelines.
PRICING AND AVAILABILITY 800.827.0807 TECH SUPPORT 800.726.8663 RETURN FOR REPAIR 256.963.8722 www.adtran.com 61180405L1-22A
Power OK but Does Not Achieve Loop Sync (DSL LED is red)
- Verify that the loop conforms with CSA guidelines (length, etc.).
- Verify that the Loop Loss at 200 kHz is not greater than 36 dB.
- Verify that noise on the DSL Loop is within acceptable limits.
- If the above conditions pass and Loop Sync is still not available, replace the unit with an FT1 DP unit known to be in good working condition.
1. All loops are non-loaded only. 2. For loops with 26 AWG cable, the maximum loop length, including bridge tap lengths is 9 kft. 3. For loops with 24 AWG cable, the maximum loop length including bridge taps is 12 kft. 4. Any single bridge tap is limited to 2 kft. 5. Total bridge tap length is limited to 2.5 kft. 6. The total length of multi-gauge cable containing 26 AWG cable must not exceed 12 - {(3 * L26)/(9 - Lbtap)} in kft where L26 = total length of 26 AWG, excluding bridge taps and Lbtap = total length of all bridge taps, in kft.
FNID
- Responds to a latching NEI loopback when transmitted in the first DS0 time slot of the selected channels. Data in all selected channels is looped back toward the network, after completion.
- Loopbacks can also be initiated from the craft interface of the FT1 DP or FNID.
ADDITIONAL GUIDELINES
COMPLIANCE
An approximation for the maximum amount of background noise on a DSL loop, measured using a 50 kilobit filter is less than or equal to 31 dBrn.
- An approximation for the maximum amount of impulse noise on a DSL loop, measured using a 50 kilobit filter, is less than or equal to 50 dBrn.
- These approximations are guidelines only and may vary slightly depending on different loops. Adhering to the guidelines should produce performance greater than a 10-7 BER.
Warning: This product must be installed in a shelf or mounting that has a compatible frame ground connection on the edge finger connector. Voltages up to -200 VDC may be present on the telecommunications wiring.
Testing Guide FT1 DP
- Responds to a latching OCU loopback when transmitted in the first DS0 time slot of the selected channels. Data in all selected channels is looped back toward the network, after completion.
- For local testing, a TPI 108/109, or equivalent, can be connected to the FT1 DP’s test access jacks, located on the front panel of the unit. The test set must be configured for near logic.
- Loopbacks can also be initiated from the FT1 DP’s loopback menu, accessible from the craft interface, using a VT100 terminal or equivalent.
WARRANTY Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s order for use in the U.S. is ten (10) years. For a complete faxback copy of ADTRAN’s U.S. and Canada Carrier Networks Equipment Warranty: (877) 457-5007, Document # 414.