For the Adtran Express 3000

Page 61

Chapter 3. Using the Express Configuration Program

Instructions for Copying Profiles (Continued) Step

Action

4

From the Name field, select the profile you want to copy. (Ensure that the name of the profile you want to copy is displayed in the Name field before continuing.)

5

Click the Copy button, and a new profile is created.

Deleting Profiles Follow the steps below to delete profile - either ISDN or User. Instructions for Deleting Profiles Step

Action

1

Open the ADTRAN Express Configuration program.

2

On the left panel of the Express Configuration program window, click on either isdn setup (to view the current ISDN profile) or profile setup (to view the current User profile).

3

Click the Setup button to open the setup window.

4

From the Name field, select the profile you want to delete. (Ensure that the name of the profile you want to delete is displayed in the Name field before continuing.)

5

Click the Delete button.

6

At the prompt, click the Yes button to delete the profile.

61203153L2-20

Express 3000 User Manual

3-21

Page 62

Chapter 3. Using the Express Configuration Program

Importing Profiles Follow the steps below to import profiles - either ISDN or User. Instructions for Importing Profiles Step

Action

1

Open the ADTRAN Express Configuration program.

2

On the left panel of the Express Configuration program window, click on either isdn setup (to view the current ISDN profile) or profile setup (to view the current User profile).

3

Click the Setup button to open the setup window.

4

Click the Import button.

5

In the File Name field, type in the file name to import, or browse and select the file name with the mouse.

6

Click the Open button.

Exporting Profiles Follow the steps below to export profiles - either ISDN or User. Instructions for Exporting Profiles Step

Action

1

Open the ADTRAN Express Configuration program.

2

On the left panel of the Express Configuration program window, click either isdn setup (to view the current ISDN profile) or profile setup (to view the current User profile).

3

Click the Setup button to open the setup window.

4

Select the name of the profile to export from the Name field. (Ensure that the name of the profile you want to export is displayed in the Name field before continuing.)

5

Click the Export button.

3-22

Express 3000 User Manual

61203153L2-20

Page 63

Chapter 3. Using the Express Configuration Program

Instructions for Exporting Profiles (Continued) Step

Action

6

In the File Name field, type in the file name to export (Windows automatically adds the .ecf extension).

7

Click the Save button.

Reading Configuration Information into the Current Profile Follow the steps below to read configuration information into the current profile - either ISDN or User. Instructions for Reading Configuration Information Step

Action

1

Open the ADTRAN Express Configuration program.

2

On the left panel of the Express Configuration program window, click on either isdn setup (to view the current ISDN profile) or profile setup (to view the current User profile).

3

Click the Setup button to open the setup window.

4

Select the name of the profile to read from the Name field. (Ensure that the name of the profile you want to read is displayed in the Name field before continuing.)

5

Click the Read button.

USING DIAGNOSTICS The option, diagnostics, provides detailed information about the status of the Express 3000 - both local and remote units (see Figure 3-5 on page 3-24).

61203153L2-20

Express 3000 User Manual

3-23

Page 64

Chapter 3. Using the Express Configuration Program

Figure 3-5. Diagnostics Window

Diagnosing Local Units You can collect information about local units using the diagnostics option. Click on the appropriate button to access the information you want. Displaying the Unit’s Current Status The Unit Info button (under diagnostics) displays the current status of several items: ISDN Loop Status, Firmware Version, Firmware Checksum, and the status of an external modem. Displaying the Express 3000’s Caller ID Log Buffer Click the Caller ID button (under diagnostics) to display the caller’s telephone number for incoming Voice and Audio calls while the log is open. To clear the contents of the log buffer, click the Clear button. Retrieving Current Settings To retrieve the current Express 3000 settings, click the Register Dump button (under diagnostics). The current settings display in a format identical to the Preview list (see Preview Tab on page 3-11 or page 3-18).

3-24

Express 3000 User Manual

61203153L2-20

Page 65

Chapter 3. Using the Express Configuration Program

Diagnosing Connection Problems You can diagnose many connection problems by viewing the Status Buffer messages returned from the ISDN network and the ADTRAN Express 3000. Access these messages by clicking the Status Buffer button (under diagnostics). Launching Terminal Programs Launch the terminal program specified in the preferences option (Program Name) by clicking the Terminal button (under diagnostics).

Diagnosing Remote Units With the diagnostics option, you can collect information about remote units. Enter the phone number of the remote unit and a password, if required. Then click on the appropriate button to access the information you want. Buttons include Test, Register Dump, Config, and Status Buffer. Testing a Remote Unit Follow the steps below to begin testing a remote unit. Instructions for Testing a Remote Unit Step

Action

1

Click the Test button (under diagnostics).

2

Choose the number of B channels with which to test.

3

Click Start to begin the remote test.

Configuring a User Profile on a Remote Unit To configure a User profile on a remote unit, click the Config button (under diagnostics). (See also Using Profiles on page 3-7.) Retrieving Current Settings from a Remote Unit To retrieve the current settings from a remote unit, click the Register Dump button (under diagnostics). The current settings display in a format identical to the Preview list (see Preview Tab on page 3-11 or page 3-18).

61203153L2-20

Express 3000 User Manual

3-25

Page 66

Chapter 3. Using the Express Configuration Program

Retrieving Status Buffer Information from a Remote Unit To retrieve Status Buffer information from a remote unit, click the Status Buffer button (under diagnostics). Status Buffer information begins with the most recent call.

CUSTOMIZING THE ADTRAN EXPRESS CONFIGURATION PROGRAM The preferences option on the left panel contains controls that let you modify automatic features (see Figure 3-6).

Figure 3-6. Preferences Window

Detecting the Connection When the Auto-Detect Express 3000 checkbox is selected (under preferences), the Express Configuration program automatically detects the presence of the Express 3000 on startup. Normally, you won’t make changes to this state. However, if you have opted to uncheck this box, you can use the connection features Communication Port and Model to re-define the connection, and when you click Apply this setup is detected. You can also click the Auto-Detect button (under pref-

3-26

Express 3000 User Manual

61203153L2-20

Page 67

Chapter 3. Using the Express Configuration Program erences) to instruct the program to detect the connection without your assistance.

Automatically Detecting the Unit on Startup To instruct the ADTRAN Express Configuration program to automatically detect on startup an Express 3000 unit on COM ports 1 through 4, check the Auto-Detect Express 3000 checkbox (under preferences). This feature defaults to the auto-detect state. Uncheck the box to disable auto-detection. ADTRAN recommends that you use this feature to automatically detect SPIDs and Switch Types, thus greatly reducing the occurrence of time-consuming problems.

Using Caller ID Caller ID allows you to view the number of an incoming Voice or Audio call via a pop-up menu on your computer screen. To enable Caller ID, check the Caller ID and capture COM port checkbox (under preferences). If you want Caller ID information to display on the screen when you are not using a terminal application or dial-up networking, check Capture COM Port on the Tray Tool menu (see also Capture COM Port on page 3-4). You can also view information in the Caller ID log buffer (see Displaying the Express 3000’s Caller ID Log Buffer on page 3-24).

Using Terminal Software for Diagnostics You can specify a software program to use for diagnostic test purposes. Under preferences > Terminal Software, enter the Program Name and Program Parameters. With this information entered, when you click Terminal (under diagnostics), the program designated in these fields launches.

61203153L2-20

Express 3000 User Manual

3-27

Page 68

Chapter 3. Using the Express Configuration Program

USING THE WIZARD The Express Configuration Software Wizard option guides you through the process of configuring your Express 3000. Before activating the Wizard, ensure that the Express 3000 is connected to your computer and that it is powered on, and quit any programs that may be using the Express 3000. To activate the Wizard, click on the wizard option in the left panel. The window shown in Figure 3-7 opens.

Figure 3-7. ADTRAN Express Configuration Wizard As you follow the on-screen instructions and click Next, the figure shown in Figure 3-8 on page 3-29 opens and the Wizard prompts you to enter the following information: Area Code, ISDN Phone Number 1, and ISDN Phone Number 2. The telephone company from which you bought your ISDN service should provide you with this information. If you have problems with your ISDN service and need to contact an ISDN Support Center, see Telephone Company Contacts for ISDN Service on page ix.

3-28

Express 3000 User Manual

61203153L2-20

Page 69

Chapter 3. Using the Express Configuration Program

Figure 3-8. Window for Entering ISDN Phone Numbers

When you click Next again, a new window opens (see Figure 3-9) for entering the Switch Type, SPID 1, and SPID 2; however, you may not need to enter this information as the Wizard uses advanced features to auto-detect SPIDs and Switch Type.

Figure 3-9. Window for Entering SPID Numbers

61203153L2-20

Express 3000 User Manual

3-29

Page 70

Chapter 3. Using the Express Configuration Program

Automatically Running the Wizard on Startup To instruct the ADTRAN Express Configuration program to automatically run the Wizard on startup, check the Auto-Run Wizard checkbox (under preferences). To disable this feature, uncheck the checkbox.

LOCATING INFORMATION ABOUT THE PROGRAM To find the version number and registration information about the ADTRAN Express Configuration program, click on about on the left panel of the GUI.

3-30

Express 3000 User Manual

61203153L2-20