Express 3000 User Manual: Chapter 3 Using the Express Configuration Program, pages 51 to 60

Pages 51 to 60 of 146, from Express 3000 User Manual

The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Adtran Express 3000

Page 51

Chapter 3. Using the Express Configuration Program

Preview Tab The Preview tab window displays a list of the configuration parameters and their values for the current profile. ATS refers to the AT commands for that configuration parameter, Description refers to the particular configuration parameter, and Value lists the corresponding parameter value. User Profile Window The User profile window contains five tabs: General, Protocols, Phone List, Advanced, and Preview. The General, Protocols, Phone List, and Advanced tabs contain fields for setting parameters. The Preview tab lists information about the profile shown in the Name box.

Figure 3-4. User Profile Setup Window

61203153L2-20

Express 3000 User Manual

3-11

Page 52

Chapter 3. Using the Express Configuration Program

General Tab The General Tab lets you set Protocol, DTE, and POTS parameters. Protocol Sets the protocol type: PPP Async-Sync, Async Bonding, V120, Fallback. The Express 3000 communicates with many different types of telecommunications equipment including other Express 3000 units, other ISDN terminal adapters, and PPP-compatible devices. Communication between such devices requires various rate adaption protocols supporting various bit rates and RS-232 connector settings (protocol type). PPP Mode Selects the PPP mode the Express 3000 uses: Point-to-Point (PPP) Async-to-Sync, Multilink PPP (MP), or PPP with Compression. Enable Bandwidth on Demand Uses the thresholds defined in the Protocols tab to bring up and down multilink channels, when this feature is enabled. Disable BACP Controls the negotiation of Bandwidth Allocation Control Protocol (BACP). BACP allows the client and server to exchange phone number information and bring up and down channels, as needed. Check Enable Bandwidth on Demand to use this feature. DTR Options Sets the following DTR options:

3-12

Ignore DTR

Disregards the state of the data terminal ready (DTR) signal on the EIA-232.

AT Command when Off

Forces the unit into the AT command processor mode when DTR is not asserted. To return online, DTR must be asserted and the ATO command must be issued.

Answer if On

Answers incoming calls only if DTR is asserted.

Idle when Off

Forces an end to the current call when DTR is no longer asserted. Express 3000 User Manual

61203153L2-20

Page 53

Chapter 3. Using the Express Configuration Program

Flow Control Allows communication devices (for example, the Express 3000 and a PC) to deal with one device sending data at a rate higher than the other device. Hardware

Controls the data transmission between the terminal (PC) and the Express 3000 (via EIA-232 pins). Recommended for high-speed data transmission.

Software

Uses characters embedded in the communication software to control the data transmission. The control characters are known as XON/XOFF. Typically used in slower transmission of data.

No Control

Disables any type of flow control.

Data Call Type Selects the Call Type according to the ISDN line configuration. Speech

Directs call control software to request a Speech circuit as the bearer capability for outgoing calls. Use with ISDN lines configured for voice service. In some areas voice service is less expensive than data service. A Speech call type does not guarantee an end-to-end digital connection with some local and long distance carriers.

Audio

Directs call control software to request a 3.1 kHz Audio circuit as the bearer capability for outgoing calls. Used with an ISDN line configured for voice service. In some areas audio service is less expensive than data service. An Audio call type does not guarantee an endto-end digital connection with some local and long distance carriers.

Data 56kbps Directs call control software to request a 64 kbps data circuit that is rate-adapted down to 56 kbps. Data 64kbps Instructs call control software to request an unrestricted 64 kbps data circuit. (Default for the Express 3000.)

61203153L2-20

Express 3000 User Manual

3-13

Page 54

Chapter 3. Using the Express Configuration Program

Data Over Voice Allows data calls to be placed using a Speech Call Type. If a usage charge for data exists in your area, you may benefit from this option. Call Routing Specifies how the Express 3000 routes incoming voice calls. Options include the following: All Calls to DTE

Routes all calls to the EIA-232 port, regardless of Call Type.

Speech Calls to POTS

Routes calls with a Speech call type to the POTS ports. Calls with Data 56k, Data 64k, and Audio are routed to the EIA-232 port.

Speech/Audio Calls Routes calls with Speech and Audio call types to to POTS the POTS ports. Calls with Data 56k and Data 64k are routed with the EIA-232 port. Enable Distinctive Ringing Instructs the Express 3000 to use distinctive rings that are easily recognized on POTS ports 1 and 2.

Protocols Tab The Protocols Tab provides you with fields for defining the point-topoint protocol (PPP) type. Options include the following: Enable AO/DI Configures the unit to operate in AO/DI mode when placing PPP calls. AO/DI allows the unit to place X.25 packet calls over the D channel. This feature requires that X.25 packet service be purchased from your ISDN service provider and AO/DI service be purchased from you Internet Service Provider. Raise Threshold Defines the percentage of available bandwidth that must be in use before an additional channel is added. A very high Raise Threshold sends the most packets on the D or, initial, B channel, before adding more B channels. A very low Raise Threshold sends a minimum number of packets on the initial channel. Raise Threshold

3-14

Express 3000 User Manual

61203153L2-20

Page 55

Chapter 3. Using the Express Configuration Program works in conjunction with Add Time to increase bandwidth, if it is available. Lower Threshold Defines the percentage of available bandwidth that must be in use to maintain bandwidth levels. If the bandwidth in use falls below this level for longer than Drop Time, a channel drops. A very high Drop Threshold increases the number of channels used, which could increase costs. Add Time Defines the length of time that bandwidth must remain above Raise Threshold before adding a channel. Drop Time Defines the length of time that bandwidth must remain below Lower Threshold before dropping a channel. Available Channels Sets the number of available channels to be used in an AO/DI call. From the Protocols Tab, you can also define the BONDING specifications using the following options: Type Defines the type of equipment used in a call. Set to ADTRAN Only when originating BONDING calls to ADTRAN legacy ISU equipment; otherwise, set this field to Multi-Vendor. TXINIT Specifies the length of time (in seconds) that the originating unit attempts to detect the Async BONDING negotiating pattern from the answering unit before determining Async BONDING has failed. TXFA Specifies the length of time (in seconds) both units attempt to detect the Async BONDING frame pattern when connecting a call before determining Async BONDING has failed.

61203153L2-20

Express 3000 User Manual

3-15

Page 56

Chapter 3. Using the Express Configuration Program

TXADD01 Specifies the length of time (in seconds) both units wait for an additional call to connect at the end of negotiation before determining Async BONDING has failed. TXDEQ Specifies the length of time (in seconds) both units attempt to equalize a network delay between ISDN B channels before determining Async BONDING has failed. TANULL Specifies the length of time (in seconds) the answering unit attempts to detect Async BONDING negotiation from the originating unit before determining Async BONDING has failed. TCID Specifies the length of time (in seconds) both units attempt to negotiate an agreeable value for B channels and channel capacities before determining Async BONDING has failed.

Phone List Tab Stores phone numbers used for various call accept or reject criteria. Allow only stored numbers Instructs the Express 3000 to accept only incoming calls originating from telephone numbers programmed in Stored Numbers 0 through 9. Stored Numbers Accepts and saves ten numbers used for dialing or call screening. Enable Call Rejection List Instructs the Express 3000 to compare all incoming Speech and Audio calling party numbers to the list of ten numbers in the Incoming Voice Call Rejection List. If a match between the incoming calling party number and an entry in the Incoming Voice Call Rejection List occurs, the Express 3000 refuses to ring the POTS port. Generally, the caller experiences a busy signal. A message in the Status Buffer is the only indication that a call has been rejected.

3-16

Express 3000 User Manual

61203153L2-20

Page 57

Chapter 3. Using the Express Configuration Program

Enable Anonymous Call Rejection Rejects calls where the calling party number is blocked (anonymous). These numbers normally appear as Private on a Caller ID unit. With this option selected, the Express 3000 refuses to ring the POTS ports. Generally, the caller experiences a busy signal. A message in the Status Buffer is the only indication that an anonymous call has been rejected. Incoming Voice Call Rejection List Contains ten numbers that represent the Call Rejection List. This list is used when the Enable Call Reject List option is checked. When the Express 3000 detects an incoming Voice or Audio call, the telephone number of the caller is compared to the numbers in this list. If a match is found, the call is rejected. Generally, the format for the number is one seven-digit number. If calls are not being rejected while the option is enabled and a number is programmed, check the Status Buffer for the number of the caller. The number of the caller should match exactly with the number in the Call Rejection List.

Advanced Tab Contains advanced instructions for the Express 3000. V120 Lower Layer Compatibility Sends a low-level compatibility information element as part of the setup message. Connect Timeout Sets the length of time that the Express 3000 waits for the far-end unit to answer an outgoing call. Inactivity Timer Defines the amount of time (in minutes) the Express 3000 remains idle before automatically disconnecting the current data call. A value of 0 indicates the Inactivity Timer is off. Remote Password Accepts the six digit numeric password for the remote unit called. Valid characters are 0 through 9. Alphabetic characters are not accepted. 61203153L2-20

Express 3000 User Manual

3-17

Page 58

Chapter 3. Using the Express Configuration Program

Test Timeout Defines the amount of time (in minutes) the Express 3000 tests a remote unit. Auto Answer Answers data calls in three different ways: Enabled

Automatically answers incoming data calls.

Disabled

Does not answer data calls. An AT answer command, ATA, must be issued before a call can be answered.

Dump all calls

Keeps the line free for outgoing calls by not answering incoming calls.

Disable call waiting on POTS 1 and 2 Instructs Express 3000 to disable call waiting and give callers either a ringing tone or a busy tone. Flash/Hook Default Flash/hook means to press and release the flash button on the telephone keypad. The options include Call Waiting and Conference/Transfer. Call Waiting

Flash/hook used only for call waiting.

Conference/Transfer Flash/hook used to connect conference calling parties; however, if incoming call occurs, flash/hook acts as call waiting. (See also, Call Conferencing on page 5-1.)

Preview Tab The Preview Tab window displays a list of the configuration parameters and their value for the current profile. ATS refers to the AT commands for that configuration parameter, Description refers to the particular configuration parameter, and Value lists the corresponding parameter value.

3-18

Express 3000 User Manual

61203153L2-20

Page 59

Chapter 3. Using the Express Configuration Program

Creating New Profiles Follow the steps listed below to create a new profile - either ISDN or User. Instructions for Creating New Profiles Step

Action

1

Open the ADTRAN Express Configuration program.

2

On the left panel of the Express Configuration program window, click on either isdn setup (to view the current ISDN profile) or profile setup (to view the current User profile).

3

Click the Setup button to open the setup window.

4

Click on New to create a new profile.

5

Enter a name for the new profile in the Name field.

6

Make any additional changes and click Apply.

Saving Profiles Follow the steps listed below to save a profile - either ISDN or User. Instructions for Saving Profiles Step

Action

1

Open the ADTRAN Express Configuration program.

2

On the left panel of the Express Configuration program window, click on either isdn setup (to view the current ISDN profile) or profile setup (to view the current User profile).

3

Click the Setup button to open the setup window.

4

From the Name field, select the profile you want to save. (Ensure that the name of the profile you want to save is displayed in the Name field before continuing.)

5

Click the Save button.

61203153L2-20

Express 3000 User Manual

3-19

Page 60

Chapter 3. Using the Express Configuration Program

Modifying Profiles Follow the steps listed below to modify profiles - either ISDN or User. Instructions for Modifying Profiles Step

Action

1

Open the ADTRAN Express Configuration program.

2

On the left panel of the Express Configuration program window, click on either isdn setup (to view the current ISDN profile) or profile setup (to view the current User profile).

3

Click the Setup button to open the setup window.

4

From the Name field, select the profile you want to modify. (Ensure that the name of the profile you want to modify is displayed in the Name field before continuing.)

5

Change all of the parameters as necessary (see also Using Profiles on page 3-7).

6

Click the Apply button. (You must apply the changes for them to take effect.)

Copying Profiles Follow the steps listed below to copy a profile - either ISDN or User. Instructions for Copying Profiles Step

Action

1

Open the ADTRAN Express Configuration program.

2

On the left panel of the Express Configuration program window, click on either isdn setup (to view the current ISDN profile) or profile setup (to view the current User profile).

3

Click the Setup button to open the setup window.

3-20

Express 3000 User Manual

61203153L2-20