For the Adtran Express 3000

Page 99

Appendix A

AT Commands and S-Registers

AT COMMANDS AT commands issue directions to the Express 3000 via a VT-100 terminal emulation session. The DTE serial port accepts AT commands only when no calls are established; i.e., the carrier detect (CD) signal is inactive. When a call is established, the CD signal is active and the port is used for data. The port cannot be used simultaneously to issue AT commands and transmit and receive data. After entering command mode (CD inactive), you can transmit AT commands to the Express 3000 to configure most options, dial remote Express 3000s, and initiate tests to check both the Express 3000 and the network connections.

Escape Sequence and Guard Time Delay To exit data mode (CD active) and enter command mode, the DTE serial port must transmit a proper escape sequence to the Express 3000. A specified time delay must occur between the last data character and the first escape sequence character. This delay is the guard time delay. You can change the guard time by writing a value to the S12 register. For a valid escape sequence to occur, the DTE must transmit the escape code character three times in succession with the delay between each character less than the guard time. The default escape sequence is +++ and the default guard time delay is one second.

61203153L2-20

Express 3000 User Manual

A-1

Page 100

Appendix A. AT Commands and S-Registers

Entering Text into the Command Line All command lines must begin with the AT character set in either all uppercase or all lowercase letters. After the AT attention code, the command line may contain a single command or a series of commands; however, AT commands _L1 and _L0 must be entered on a separate line and followed by Enter. When entering a series of commands, you may separate the individual commands with spaces for readability. The maximum length for a command line is 40 characters. After receiving a terminating character, the Express 3000 executes each command line. The default terminating character is a carriage return (ASCII 013), but it can be changed by writing a different value to register S3. Before transmitting the terminating character, you can edit the command line by using the backspace character (ASCII 008) to erase errors so the proper commands can be entered.

To return an active call to the on-line state, enter ATO.

Entering AT Commands To enter an AT command, type AT followed by the command; then, press the Enter key (the AT Commands list begins on page A-4). For example, ATI1 returns the software version of the Express 3000 unit.

S-REGISTERS You can change or view the Express 3000 configuration using the S-registers (the S-registers list begins on page A-9).

Reading S-Registers To read an S-register, type AT, the S-register number, a question mark, and then press the Enter key. For example, ATS0? lets you view the Auto Answer options.

A-2

Express 3000 User Manual

61203153L2-20

Page 101

Appendix A. AT Commands and S-Registers

Changing S-Registers To change an S-register, type AT, the S-register number to change, an equals sign, the numeric value to assign to the register, and then press the Enter key. For example, ATS0=2 changes the Auto Answer to 2 (dump all calls).

S-REGISTER STRINGS S-register Strings store strings of digits such as stored phone numbers and SPIDs (the S-registers String list begins on page A-16).

Reading S-Register Strings To read an S-register String, type AT, the number of the string S-register to read, a question mark, and then press the Enter key. For example, ATSS80? shows the number stored in location 0.

Changing S-Register Strings To change an S-register string, type AT, the number of the S-register string to change, an equals sign (=), the numeric string to assign to the register, and then press the Enter key. ATSS80=5551212, for example, changes the number stored in location 0 to 5551212.

Dialing a Call using AT Commands To dial a call using the DTE terminal and AT commands, on one line type ATD, ATDT, or ATDP and the telephone number; then press the Enter key. For example, ATD5551212 dials phone number 555-1212.

Disconnecting a Call using AT Commands To end an active call using the AT commands, press the break-in key sequence +++. Then type ATH and press the Enter key to hang up the line.

61203153L2-20

Express 3000 User Manual

A-3

Page 102

Appendix A. AT Commands and S-Registers

AT Commands List (Type AT and then type the command.) Command

Function

A

Answer. Places the Express 3000 in answer mode.

!DAY

Current date in the format of DDMMYY.

!FLASHLOAD

Initiate the flash software update. The terminal must be set for 57,600 bps, 8 data bits, no parity, and 1 stop bit.

!NAME1

Displays the Calling Party name from the last call on POTS port 1.

!NAME2

Displays the Calling Party name from the last call on POTS port 2.

!NUMBER1

Displays the Calling Party number from the last call on POTS port 1.

!NUMBER2

Displays the Calling Party number from the last call on POTS port 2.

!S

Displays Status Buffer.

!S1

Displays Link Status.

!TIME

Current time in the format of HHMMSS.

!V

Configuration Menu.

!Z

Detect a modem connected to the Express 3000.

D

Dial. Precedes the telephone access number [ATD5551212].

H

Hang up. Disconnects the current call.

I0

Identify unit. Commands the unit to display model number.

I1

Identify software. Commands the unit to display software version.

O

On-line. Commands the unit to go back on line.

S

S Register.

SS

S String register.

&V

Displays the contents of all S registers.

Z

Reset. Resets the AT command processor.

&W

Save. Save current configuration to EEPROM.

+++

Break in. Break in AT command processor during an active call. The break in key is defined in S2.

_Z

Resets unit.

_F

Restores factory defaults.

A-4

Express 3000 User Manual

61203153L2-20

Page 103

Appendix A. AT Commands and S-Registers

Carrier Detect (CD) Control Line Options Command

Function

&C0

CD forced on.

&C1

CD normal.

&C2

CD off with local disconnect (LOCD).

&C3

CD off with link down.

Data Terminal Ready (DTR Control Line Options) Command

Function

&D0

Ignore DTR.

&D1

DTR off forces command.

&D2

Idle when off. DTR off forces idle. (On allows auto answer.)

61203153L2-20

Express 3000 User Manual

A-5

Page 104

Appendix A. AT Commands and S-Registers

Generic Unit Configurations Command

Function

&F0

Factory Default. Restores last-saved configuration.

&F1

Internet 64K.

&F2

Internet 128K.

&F4

Remote Access 128K.

&F7

Configures unit for Dial 57.6k async.

&F8

Configures unit for Dial 115.2k async.

&F11

Configures unit for FALLBACK.

Calling Number Identifiers Command

Function

&N0

Number 1. Read far-end phone number 1 if service subscribed from telephone company.

&N1

Number 2. Read far-end phone number 2 if service subscribed from telephone company.

Clear-To-Send (CTS) Control Line Options Command

Function

&R0

Follows RTS.

&R1

Forced CTS.

Data Set Ready (DSR) Control Line Options Command

Function

&S0

DSR forced on.

&S1

DSR if call up.

&S2

DSR off if link down.

A-6

Express 3000 User Manual

61203153L2-20

Page 105

Appendix A. AT Commands and S-Registers

Dialing Options: Accessing Stored Numbers Command

Function

&Z0

Stored number 0

&Z1

Stored number 1

&Z2

Stored number 2

&Z3

Stored number 3

&Z4

Stored number 4

&Z5

Stored number 5

&Z6

Stored number 6

&Z7

Stored number 7

&Z8

Stored number 8

&Z9

Stored number 9

Local Echo Options Command

Function

E0

Echo off. Does not allow command characters typed to be displayed on the screen.

E1

Echo on. Allows the command characters typed to be displayed on the screen.

AT Command Response Message Options Command

Function

Q0

Response messages on.

Q1

Response messages off.

AT Command Response Message Types Command

Function

V1

Verbal response messages.

61203153L2-20

Express 3000 User Manual

A-7

Page 106

Appendix A. AT Commands and S-Registers

AT Command Connect Message Options Command

Function

X1-7

Connect messages with DTE rate.

Ready-To-Send (RTS) Control Line Options Command

Function

_D1

18 mS delay.

ISDN Switch Type Options Command

Function

_S1

DMS-100.

_S2

National ISDN-1.

Data Flow Control Options Command

Function

\Q0

No flow control.

\Q1

Software flow control (XON/XOFF).

\Q2

CTS only.

\Q3

Hardware flow control (RTS/CTS) factory default.

\Q4

Software from DCE only.

DTE and Modem Interface Selection Command

Function

_L0

Disable external analog modem connected to the Express 3000 modem port.

_L1

Enable external analog modem connected to the Express 3000 modem port.

A-8

Express 3000 User Manual

61203153L2-20