Express 3000 User Manual: Chapter 8 Troubleshooting

Pages 91 to 98 of 146, from Express 3000 User Manual

The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Adtran Express 3000

Page 91

Chapter 8

Troubleshooting

TROUBLESHOOTING GUIDELINES This section provides troubleshooting techniques to resolve problems that may be encountered while operating the Express 3000. If problems persist, contact ADTRAN technical support for assistance (see the inside back cover of this manual for more information). Topics covered in this chapter are listed below: •

PWR / LINE LED is off. See page 8-2

•

PWR / LINE LED flashes, and 1 and 2 LEDs are off. See page 8-2

•

PWR / LINE LED, and 1 and 2 LEDs flash green. See page 8-2

•

Dial-up connection problems. See page 8-4

•

Auto-detect Switch SPIDs remains at Link Down. See page 8-5

•

Express 3000 not detected. See page 8-6

•

External analog modem not detected. See page 8-6

•

Difficulty with 230.4 kbps operation. See page 8-7

•

Dial-up networking difficulty. See page 8-7

61203153L2-20

Express 3000 User Manual

8-1

Page 92

Chapter 8. Troubleshooting

PWR / LINE LED is off. This indicates a problem with the power to the unit. 1.

Verify that the power cord is connected to the Express 3000, and that it is plugged into a working 120 volt AC electrical outlet.

PWR / LINE LED flashes, and 1 and 2

LEDs are off. This indicates a problem with the physical connection of the ISDN line between the Express 3000 and the local telephone company. 1.

Verify that the large end of the ISDN telephone cable (provided with the Express 3000) is connected to the ISDN connector on the rear panel of the Express 3000.

2.

Verify that the small end of the same ISDN telephone cable is connected to the ISDN telephone wall jack that is installed with a Basic Rate ISDN.

3.

If steps 1 and 2 do not solve the problem, contact your local telephone service provider.

PWR / LINE LED, and 1 and 2 LEDs flash green. This indicates a configuration problem. 1. Verify that the following information has been correctly entered: • Switch Type • Service Profile Identifiers (SPIDs) • ISDN Phone Numbers

8-2

Express 3000 User Manual

61203153L2-20

Page 93

Chapter 8. Troubleshooting

PWR / LINE LED, and 1 and 2 LEDs flash green. (Continued)

2.

a.

To verify this information, click Register Dump under diagnostics on the ADTRAN Express Configuration window, or click Configuration Screen in the VT-100 menu system. To invoke the VT-100 menu system, issue the AT command AT!V from a terminal emulation package such as HyperTerminal.)

b.

You can also use Auto-Detect Express 3000 (under preferences) to automatically detect the SPIDs and the Switch Type. In the ADTRAN Express Configuration program, click wizard on the Express Configuration window or, use the Auto-Detect SPIDs / Switch option in the Configuration screen of the VT-100 menu system. (To invoke the VT-100 menu system, issue the AT command AT!V from a terminal emulation package such as HyperTerminal.)

c.

If all configuration information is correct, and the unit is properly connected, Link Status indicates Link Up. If the link status is good and calls still cannot be placed, refer to page 8-4.

Look for the following with the COM port setup: • IRQ conflicts • Wrong DTE speed If the PWR /LINE LED, and 1 and 2 LEDs flash green, sequentially, after a software upgrade, a problem occurred during the download. Restart the download using the instructions in Chapter 6. If the download fails a second time, contact ADTRAN technical support (see inside back cover).

61203153L2-20

Express 3000 User Manual

8-3

Page 94

Chapter 8. Troubleshooting

Dial-up connection problems. A variety of causes may result in dial-up connection problems. 1.

Status Buffer messages returned from the ISDN network and the Express 3000 can help diagnose many dial-up connection problems. a.

Access these messages by clicking Status Buffer (Local or Remote) on the diagnostics option on the ADTRAN Express Configuration window.

b.

Alternatively, you can access the Status Buffer by using the key sequence Ctrl+V in the VT-100 menu system. (To invoke the VT-100 menu system, issue the AT command AT!V from a terminal emulation package such as HyperTerminal.)

2.

Ensure the following to verify the correct protocol is selected:

•

PPP or V.120 generally for Internet applications

•

V.120 or Multilink PPP for work-at-home

8-4

Express 3000 User Manual

61203153L2-20

Page 95

Chapter 8. Troubleshooting

Auto-detect Switch SPIDs remains at Link Down. A Link Down condition persisting for longer than five minutes indicates a problem with the ISDN line provided from the telephone company. Usually, the ISDN physical layer device has been unable to synchronize to the network. 1.

Verify that the Express 3000 is powered on.

2.

Verify that the provided ISDN telephone cable is correctly installed between the Express 3000 and the ISDN wall jack. a.

If the wall jack does not have ISDN installed on the two middle pins (tip and ring), the Express 3000 will never synchronize to the telephone switching equipment.

b.

Call the local telephone company and have them check the ISDN line for correct operation.

61203153L2-20

Express 3000 User Manual

8-5

Page 96

Chapter 8. Troubleshooting

Express 3000 not detected. The Express 3000 may not be detected for several reasons. 1.

Verify the following: a.

The Express 3000 is powered on.

b.

No other applications are running that could be using the COM port to which the Express 3000 is attached. A Windows application does not have to be active to tie up a COM port. Be sure to check the Windows 95/98 Taskbar for any suspended applications (such as HyperTerminal) that may be using the COM port. If any applications are minimized, they must be closed before starting the ADTRAN Express Configuration program.

2.

If you are operating at 230.4 kbps, move DIP switch 1 to Off (up).

3.

Confirm that the computer has a 16650 UART.

External analog modem not detected. Verify the following: 1.

The external analog modem is powered on.

2.

The external analog modem is properly installed and configured for use with the Express Configuration program.

8-6

Express 3000 User Manual

61203153L2-20

Page 97

Chapter 8. Troubleshooting

Difficulty with 230.4 kbps operation. If the Express 3000 does not work when the DTE rate is set (inside Windows) to 230.4 kbps, verify the following: 1.

DIP switch 1 on the back of the Express 3000 is set to Off (up).

2.

A high-speed serial card with a 16650 UART is being used, and the software drivers to support the extended baud rate tables are installed.

Dial-up networking difficulty. 1.

If Windows 95/98 Dial-Up Networking cannot talk to the Express 3000, check the modem configuration for the Express 3000 and ensure the bit rate for the DTE is set correctly.

2.

If the PC is not equipped with a 16650 UART, then the fastest DTE operation speed is 115.2 kbps; ensure the speed is not higher than the PC and modem can support.

61203153L2-20

Express 3000 User Manual

8-7

Page 98

Chapter 8. Troubleshooting

8-8

Express 3000 User Manual

61203153L2-20