Page 13
Chapter 1
Terminal Description
The Accu-Time Cyber Series family of time and attendance terminals, shown in Figure 1-1, include standard, biometric, and NEMA 4X enclosure versions. Highly versatile for incorporation into many time or data collection environments, the Cyber Series offers a large user memory base of up to 1 megabyte. The Cyber Series supports standard EIA RS232 and RS485 communication formats and a TCP/IP Ethernet 10/100BASE-T interface. The many options of the Cyber Series include: • Multi-Media: Can support most standard bar code formats including:
• • • • • • • •
UPCA ABAR EAN 128 3 of 9 Interleave 2 of 5 Wiegand IATA Track I and ABA Track II magnetic stripe input (program dependent).
• Flexibility: A Cyber Series terminal can act as a stand-alone time station or as part of a local or wide area network. The terminal can also interface with virtually any host hardware or software platform. • Custom Applications: Custom programs and programmable function keys provide you with the flexibility to create a variety of options. • Reliability: A Real Time Clock (RTC) provides 12 or 24 hour time formats with quartz precision. An optional non-interruptible power supply (UPS) provides terminal operation for up to 1.5 hours during power outages. Data storage will be preserved for up to 30 hours with the memory backup system. Cyber Series Time and Attendance Terminals
1-1
Page 14
Terminal Description
Introduction
• Durability: A rugged enclosure protects circuitry from environmental conditions such as extreme temperatures and airborne dust. A NEMA 4X enclosure is available for outdoor applications.
Cyber Series Time and Attendance Terminals
1-2
Page 15
Terminal Description
Figure 1-1: Selection of Terminals from the Cyber Series Family
Biometric (CSxB)
Introduction
Standard (CSx)
NEMA 4X (CSxN)
ENROLL
Finger Geometry (CSxG)
Cyber Series Time and Attendance Terminals
1-3
Page 16
Terminal Description
Available Models
The Cyber Series family of terminals is available in many configurations. Table 1-1 lists the major properties of each model of Cyber Series terminal. .
Modem
Memory Base
Flash
Display
DIDO
Mounting
-
Opt
128K
256K
2x20
-
Gullwing
Std
-
-
128K
256K
2x20
-
Gullwing
Std
-
-
Opt
512K
256K
4x20
Opt
Lock
CS2
Std
-
Std
Opt
512K
256K
4x20
Opt
Lock
CS3
Std
-
Std
Opt
1M
512K
4x20
Opt
Lock
CSSB
Std
-
-
Opt
128K
256K
4x20
-
Gullwing
CSEB
-
Std
-
-
128K
256K
4x20
-
Gullwing
CS1B
Std
-
-
Opt
512K
256K
4x20
Opt
Lock
CS2B
Std
-
Std
Opt
512K
256K
4x20
Opt
Lock
CS3B
Std
-
Std
Opt
1M
512K
4x20
Opt
Lock
CS1N
Std
-
-
Opt
512K
256K
4x20
Opt
Flange
CS2N
Std
-
Std
Opt
512K
256K
4x20
Opt
Flange
CS3N
Std
-
Std
Opt
1M
512K
4x20
Opt
Flange
CS1G
Std
-
-
Opt
512K
256K
4x20
Opt
Lock
CS2G
Std
-
Std
Opt
512K
256K
4x20
Opt
Lock
CS3G
Std
-
Std
Opt
1M
512K
4x20
Opt
Lock
Model
Serial
CSS
Ethernet 10M
10/100M
Std
-
CSE
-
CS1
Cyber Series Time and Attendance Terminals
1-4
Introduction
Table 1-1: Cyber Series Terminal Configurations
Page 17
Terminal Description
Table 1-2 lists the specifications for Cyber Series terminals. Table 1-2: Cyber Series Specifications Display:
2 or 4 line by 20 character backlit LCD
Clock:
12 or 24 hour format - USA or International. 24-hour time stamp of data transactions
Keypad:
Software defined function keys Large 20 key tactile 4x5 matrix Custom, user-defined keypad legends
Indicators:
Yellow LED = low power Green = valid entry Red = invalid entry Link and Activity LEDS for Ethernet (optional)
Memory:
Up to 1MB and up to 512KB Flash
Programming:
ATS Universal Command Set modules, C programming language, or third party custom application packages
Self-Test:
On-board set-up, test, and diagnostics
Interfaces:
• • • • • •
Enclosures:
Choice of: • Die cast aluminum housing with key-lockable base • Unit construction gullwing mount • NEMA 4X
Power:
• •
+10 to +17VDC (+12VDC @ 300mA nominal) Non-interruptible power source w/charger
Environment:
•
32 to 110 degrees Fahrenheit (0 to 43 degrees Centigrade) Heated NEMA 4X enclosure option available for operation below 32° F (0° C) 5% to 95% relative humidity, non-condensing
•
EIA standard RS232 or RS485 Wand DIDO TCP/IP Ethernet 10/100BASE-T 802.3 (optional) Modem (optional) Serial interface printer port (optional)
Cyber Series Time and Attendance Terminals
Introduction
Specifications
1-5
Page 18
Terminal Description
Table 1-2: Cyber Series Specifications • • • • •
Accessories:
Certifications:
•
Standard terminal: 7.13” x 7.33” x 4.00” (18.1cm x 18.6cm x 10.2cm) Weight: 3.0 lb (1.4kg) Biometric terminal (1:1): 7.25” x 10.00” x 4.00” (18.4cm x 25.4cm x 10.2cm) Weight: 4.5 lb (2.0kg) Biometric terminal (1:many): 7.13” x 7.33” x 4.00” (18.6cm x 18.4cm x 10.2cm) Weight: 3.0 lb (1.4kg) NEMA 4X terminal: 8.5” x 10.5” x 6.25” (21.6cm x 26.7cm x 15.9cm) Weight: 8.6 lbs (3.9kg) Finger geometry terminal: 12.02” x 7.4” x 7.1” (30.6cm x 18.9cm x 18.0cm) Weight: 9.2 lb (4.15kg)
• • •
Integrated/external visible/infrared bar code and magnetic stripe track II slot readers Integrated/external 26- or 34-bit proximity readers Solid state or dry contact relay modules Serial interface printer port
• • •
FCC Part 15 Class A CE NEMX 4X (for CSxN terminals)
Cyber Series Time and Attendance Terminals
1-6
Introduction
Dimensions:
Page 19
Terminal Description
Cyber Series terminals support three forms of connectivity to a host computer: serial RS232, serial RS485, and Ethernet.
RS232
An RS232 serial line connection is the simplest connection between terminal and host. Requiring only a modular cable and COMM port adapter, installation is quick and easy. Cable length between host and terminal is limited, however, to a maximum of 50 wire-feet, and the number of terminals is limited to the number of COMM ports available. Serial RS232 connections support only a simple communication protocol with limited verification. An RS232 connection typically uses ATS Poll Protocol, which is described in a separate manual.
RS485
RS485 serial line connections may be suitable for more elaborate installations. RS485 junction boxes support multiple terminals, allowing up to 32 terminals to be installed. Cable length of all combined host/terminal drop points should not exceed 5,000 wire-feet. An RS485 connection typically uses ATS Poll Protocol, which is described in a separate manual.
Ethernet
Ethernet provides the most robust network connection between the host and terminal. Using TCP/IP communication protocol and CAT-5 cable, cable lengths between a terminal and an Ethernet network hub can be up to 328 wire-feet. AccuTime Systems implements Ethernet IEEE 802.3, with a default host port of 2500 and Microsoft or UNIX Berkely sockets.
Ethernet Communication Acknowledgements
Cyber Series terminals support three levels of Ethernet communication acknowledgement: Normal, One-Way, AppAck, and Two-Way AppAck (TWAA), explained below. For best reliability, ATS STRONGLY RECOMMENDS the use of Two-Way Application ACK ONLY!
Normal
Normal level of communication acknowledgement reflects the guaranteed delivery features built into the TCP/IP protocol. TCP/IP guarantees delivery of data packets to their destination (host or terminal). It does not guarantee that they were processed correctly. ATS does not recommend using this level of acknowledgement.
One-Way Application Ack
One-Way application acknowledgement guarantees that data sent from a terminal to a host has been delivered and processed. It does not guarantee that data sent from a host to a terminal has been processed. ATS does not recommend using this level of acknowledgement.
Cyber Series Time and Attendance Terminals
1-7
Introduction
Connectivity
Page 20
Terminal Description
Two-way application acknowledgement (TWAA) ensures not only that the host/ server has received the last transaction from the network, but also that the terminal has in turn received the transaction from the host. ATS recommeds that you ALWAYS use Two-Way Application ACK. The AppAck that is used by the terminal is also used by the host. Refer above for AppAck definition. Should there be a connection failure, the terminal will continue from where it left off upon reconnection. Therefore, upon reconnection, the host should also continue from where it left off. The only exception is when the terminal resets. In this case, a power-on message transmits, which indicates that the process needs to be restarted. The only case where the terminal will reset of its own accord is during a C-load or Flash load whereupon records are received out of sequence. If the terminal transmits a packet out of sequence by more than one (1), the host will receive an AG00 data packet from the terminal, which recognizes that the terminal does not contain a C-load. If the BG00 data packet is received, the C-load has been transmitted successfully. The Accu-Time terminal operates over non-blocking sockets. Upon a socket error, call the Windows function ‘Get last error’ for detection. If it is anything but ‘e would block,’ then close the socket, listen for the terminal, reconnect, and pick up where it was left off. If ‘e would block’ lasts longer than 3.5 minutes, then close the socket. To ensure and validate that the terminal and host are in the TWAA mode, the following packets must be sent separately across a connection. \A!gs sp ATSspREQ=request
This packet requests for AppAck mode. In the event that TWAA is not present, the terminal will remain in AppAck mode. A!gs sp ATSspTWY=two-way app ack
This packet designates the TWAA mode \A!gs sp ATSspCFG=verify
This packet verifies the mode by returning a response (none, 1 way, or 2 way).
Cyber Series Time and Attendance Terminals
1-8
Introduction
Two-Way Application ACK
Page 21
Terminal Description
Figure 1-2: Ethernet Communication Acknowledgements
Normal
AppAck
Two-Way AppAck
ATS NOT
ATS REQ
ATS TWY
Data is transferred by TCP/IP packet exchange without any upper layer delivery verification.
When data is transferred from the terminal to the host, delivery verification is made by the host returning an upper layer acknowledgement message, AppAck.
When data is transferred from the terminal to the host or from the host to the terminal, delivery verification is made by the host or the terminal returning an upper layer acknowledgement message, AppAck.
The terminal does not delete the data from its buffer until it receives this verification. If the host does not receive the data or the terminal does not receive acknowledgement, the terminal will resend the same data every 30 seconds until it receives a valid Ack response from the host. After five resends, the terminal will perform a reconnect sequence. No data delivery verification is present in this mode for host-to-terminal transfers.
Cyber Series Time and Attendance Terminals
ATS ACK
Transmitted data is not deleted by either the host or the terminal until it receives this verification from the receiver of the data. If the host or the terminal does not receive the data or either does not receive a valid acknowledgement, the originator will resend the data every 30 seconds until a valid acknowledgement is received. After 5 resends, the host or terminal will initiate a reconnect sequence.
1-9
Introduction
ATS ACK