Accu-Time Cyber Series Standard, Biometric, and NEMA 4X Time and Attendance Terminals: Chapter 1 Terminal Description

Pages 13 to 21 of 91, from Accu-Time Cyber Series Standard, Biometric, and NEMA 4X Time and Attendance Terminals

The original document is the PDF (952 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Accu-Time CS2100 and Accu-Time CSS110

Page 13

Chapter 1

Terminal Description

The Accu-Time Cyber Series family of time and attendance terminals, shown in Figure 1-1, include standard, biometric, and NEMA 4X enclosure versions. Highly versatile for incorporation into many time or data collection environments, the Cyber Series offers a large user memory base of up to 1 megabyte. The Cyber Series supports standard EIA RS232 and RS485 communication formats and a TCP/IP Ethernet 10/100BASE-T interface. The many options of the Cyber Series include: • Multi-Media: Can support most standard bar code formats including:

• • • • • • • •

UPCA ABAR EAN 128 3 of 9 Interleave 2 of 5 Wiegand IATA Track I and ABA Track II magnetic stripe input (program dependent).

• Flexibility: A Cyber Series terminal can act as a stand-alone time station or as part of a local or wide area network. The terminal can also interface with virtually any host hardware or software platform. • Custom Applications: Custom programs and programmable function keys provide you with the flexibility to create a variety of options. • Reliability: A Real Time Clock (RTC) provides 12 or 24 hour time formats with quartz precision. An optional non-interruptible power supply (UPS) provides terminal operation for up to 1.5 hours during power outages. Data storage will be preserved for up to 30 hours with the memory backup system. Cyber Series Time and Attendance Terminals

1-1

Page 14

Terminal Description

Introduction

• Durability: A rugged enclosure protects circuitry from environmental conditions such as extreme temperatures and airborne dust. A NEMA 4X enclosure is available for outdoor applications.

Cyber Series Time and Attendance Terminals

1-2

Page 15

Terminal Description

Figure 1-1: Selection of Terminals from the Cyber Series Family

Biometric (CSxB)

Introduction

Standard (CSx)

NEMA 4X (CSxN)

ENROLL

Finger Geometry (CSxG)

Cyber Series Time and Attendance Terminals

1-3

Page 16

Terminal Description

Available Models

The Cyber Series family of terminals is available in many configurations. Table 1-1 lists the major properties of each model of Cyber Series terminal. .

Modem

Memory Base

Flash

Display

DIDO

Mounting

-

Opt

128K

256K

2x20

-

Gullwing

Std

-

-

128K

256K

2x20

-

Gullwing

Std

-

-

Opt

512K

256K

4x20

Opt

Lock

CS2

Std

-

Std

Opt

512K

256K

4x20

Opt

Lock

CS3

Std

-

Std

Opt

1M

512K

4x20

Opt

Lock

CSSB

Std

-

-

Opt

128K

256K

4x20

-

Gullwing

CSEB

-

Std

-

-

128K

256K

4x20

-

Gullwing

CS1B

Std

-

-

Opt

512K

256K

4x20

Opt

Lock

CS2B

Std

-

Std

Opt

512K

256K

4x20

Opt

Lock

CS3B

Std

-

Std

Opt

1M

512K

4x20

Opt

Lock

CS1N

Std

-

-

Opt

512K

256K

4x20

Opt

Flange

CS2N

Std

-

Std

Opt

512K

256K

4x20

Opt

Flange

CS3N

Std

-

Std

Opt

1M

512K

4x20

Opt

Flange

CS1G

Std

-

-

Opt

512K

256K

4x20

Opt

Lock

CS2G

Std

-

Std

Opt

512K

256K

4x20

Opt

Lock

CS3G

Std

-

Std

Opt

1M

512K

4x20

Opt

Lock

Model

Serial

CSS

Ethernet 10M

10/100M

Std

-

CSE

-

CS1

Cyber Series Time and Attendance Terminals

1-4

Introduction

Table 1-1: Cyber Series Terminal Configurations

Page 17

Terminal Description

Table 1-2 lists the specifications for Cyber Series terminals. Table 1-2: Cyber Series Specifications Display:

2 or 4 line by 20 character backlit LCD

Clock:

12 or 24 hour format - USA or International. 24-hour time stamp of data transactions

Keypad:

Software defined function keys Large 20 key tactile 4x5 matrix Custom, user-defined keypad legends

Indicators:

Yellow LED = low power Green = valid entry Red = invalid entry Link and Activity LEDS for Ethernet (optional)

Memory:

Up to 1MB and up to 512KB Flash

Programming:

ATS Universal Command Set modules, C programming language, or third party custom application packages

Self-Test:

On-board set-up, test, and diagnostics

Interfaces:

• • • • • •

Enclosures:

Choice of: • Die cast aluminum housing with key-lockable base • Unit construction gullwing mount • NEMA 4X

Power:

• •

+10 to +17VDC (+12VDC @ 300mA nominal) Non-interruptible power source w/charger

Environment:

•

32 to 110 degrees Fahrenheit (0 to 43 degrees Centigrade) Heated NEMA 4X enclosure option available for operation below 32° F (0° C) 5% to 95% relative humidity, non-condensing

•

EIA standard RS232 or RS485 Wand DIDO TCP/IP Ethernet 10/100BASE-T 802.3 (optional) Modem (optional) Serial interface printer port (optional)

Cyber Series Time and Attendance Terminals

Introduction

Specifications

1-5

Page 18

Terminal Description

Table 1-2: Cyber Series Specifications • • • • •

Accessories:

Certifications:

•

Standard terminal: 7.13” x 7.33” x 4.00” (18.1cm x 18.6cm x 10.2cm) Weight: 3.0 lb (1.4kg) Biometric terminal (1:1): 7.25” x 10.00” x 4.00” (18.4cm x 25.4cm x 10.2cm) Weight: 4.5 lb (2.0kg) Biometric terminal (1:many): 7.13” x 7.33” x 4.00” (18.6cm x 18.4cm x 10.2cm) Weight: 3.0 lb (1.4kg) NEMA 4X terminal: 8.5” x 10.5” x 6.25” (21.6cm x 26.7cm x 15.9cm) Weight: 8.6 lbs (3.9kg) Finger geometry terminal: 12.02” x 7.4” x 7.1” (30.6cm x 18.9cm x 18.0cm) Weight: 9.2 lb (4.15kg)

• • •

Integrated/external visible/infrared bar code and magnetic stripe track II slot readers Integrated/external 26- or 34-bit proximity readers Solid state or dry contact relay modules Serial interface printer port

• • •

FCC Part 15 Class A CE NEMX 4X (for CSxN terminals)

Cyber Series Time and Attendance Terminals

1-6

Introduction

Dimensions:

Page 19

Terminal Description

Cyber Series terminals support three forms of connectivity to a host computer: serial RS232, serial RS485, and Ethernet.

RS232

An RS232 serial line connection is the simplest connection between terminal and host. Requiring only a modular cable and COMM port adapter, installation is quick and easy. Cable length between host and terminal is limited, however, to a maximum of 50 wire-feet, and the number of terminals is limited to the number of COMM ports available. Serial RS232 connections support only a simple communication protocol with limited verification. An RS232 connection typically uses ATS Poll Protocol, which is described in a separate manual.

RS485

RS485 serial line connections may be suitable for more elaborate installations. RS485 junction boxes support multiple terminals, allowing up to 32 terminals to be installed. Cable length of all combined host/terminal drop points should not exceed 5,000 wire-feet. An RS485 connection typically uses ATS Poll Protocol, which is described in a separate manual.

Ethernet

Ethernet provides the most robust network connection between the host and terminal. Using TCP/IP communication protocol and CAT-5 cable, cable lengths between a terminal and an Ethernet network hub can be up to 328 wire-feet. AccuTime Systems implements Ethernet IEEE 802.3, with a default host port of 2500 and Microsoft or UNIX Berkely sockets.

Ethernet Communication Acknowledgements

Cyber Series terminals support three levels of Ethernet communication acknowledgement: Normal, One-Way, AppAck, and Two-Way AppAck (TWAA), explained below. For best reliability, ATS STRONGLY RECOMMENDS the use of Two-Way Application ACK ONLY!

Normal

Normal level of communication acknowledgement reflects the guaranteed delivery features built into the TCP/IP protocol. TCP/IP guarantees delivery of data packets to their destination (host or terminal). It does not guarantee that they were processed correctly. ATS does not recommend using this level of acknowledgement.

One-Way Application Ack

One-Way application acknowledgement guarantees that data sent from a terminal to a host has been delivered and processed. It does not guarantee that data sent from a host to a terminal has been processed. ATS does not recommend using this level of acknowledgement.

Cyber Series Time and Attendance Terminals

1-7

Introduction

Connectivity

Page 20

Terminal Description

Two-way application acknowledgement (TWAA) ensures not only that the host/ server has received the last transaction from the network, but also that the terminal has in turn received the transaction from the host. ATS recommeds that you ALWAYS use Two-Way Application ACK. The AppAck that is used by the terminal is also used by the host. Refer above for AppAck definition. Should there be a connection failure, the terminal will continue from where it left off upon reconnection. Therefore, upon reconnection, the host should also continue from where it left off. The only exception is when the terminal resets. In this case, a power-on message transmits, which indicates that the process needs to be restarted. The only case where the terminal will reset of its own accord is during a C-load or Flash load whereupon records are received out of sequence. If the terminal transmits a packet out of sequence by more than one (1), the host will receive an AG00 data packet from the terminal, which recognizes that the terminal does not contain a C-load. If the BG00 data packet is received, the C-load has been transmitted successfully. The Accu-Time terminal operates over non-blocking sockets. Upon a socket error, call the Windows function ‘Get last error’ for detection. If it is anything but ‘e would block,’ then close the socket, listen for the terminal, reconnect, and pick up where it was left off. If ‘e would block’ lasts longer than 3.5 minutes, then close the socket. To ensure and validate that the terminal and host are in the TWAA mode, the following packets must be sent separately across a connection. \A!gs sp ATSspREQ=request

This packet requests for AppAck mode. In the event that TWAA is not present, the terminal will remain in AppAck mode. A!gs sp ATSspTWY=two-way app ack

This packet designates the TWAA mode \A!gs sp ATSspCFG=verify

This packet verifies the mode by returning a response (none, 1 way, or 2 way).

Cyber Series Time and Attendance Terminals

1-8

Introduction

Two-Way Application ACK

Page 21

Terminal Description

Figure 1-2: Ethernet Communication Acknowledgements

Normal

AppAck

Two-Way AppAck

ATS NOT

ATS REQ

ATS TWY

Data is transferred by TCP/IP packet exchange without any upper layer delivery verification.

When data is transferred from the terminal to the host, delivery verification is made by the host returning an upper layer acknowledgement message, AppAck.

When data is transferred from the terminal to the host or from the host to the terminal, delivery verification is made by the host or the terminal returning an upper layer acknowledgement message, AppAck.

The terminal does not delete the data from its buffer until it receives this verification. If the host does not receive the data or the terminal does not receive acknowledgement, the terminal will resend the same data every 30 seconds until it receives a valid Ack response from the host. After five resends, the terminal will perform a reconnect sequence. No data delivery verification is present in this mode for host-to-terminal transfers.

Cyber Series Time and Attendance Terminals

ATS ACK

Transmitted data is not deleted by either the host or the terminal until it receives this verification from the receiver of the data. If the host or the terminal does not receive the data or either does not receive a valid acknowledgement, the originator will resend the data every 30 seconds until a valid acknowledgement is received. After 5 resends, the host or terminal will initiate a reconnect sequence.

1-9

Introduction

ATS ACK