Page 61

Basic Troubleshooting and Maintenance

Introduction

5-1

The Model 30 hardware was specifically designed for the tough industrial environment. The unit does not need anything more than some basic cleaning and an occasional check-up to insure its best performance. This chapter provides you with a cleaning procedure and some troubleshooting techniques. The purpose of these procedures is to help prevent the chance of degraded scan head performance. Additionally, these steps help maintenance personnel to locate potential problems that may result in a scan head failure in the future.

Model 30 Hardware Operations Manual

Page 62

Chapter 5

5-2

General Cleaning and Maintenance

The Model 30 enclosure is tightly sealed to prevent dust or dirt from entering the unit. Nothing inside of the Model 30 needs to be cleaned on a regular basis. If the Model 30 needs to be repaired, do not open the unit. The Model 30 is designed to be shipped back for repair. Refer to the Customer Service Section of this manual. To insure proper operation and decrease the chance of scan head degradation, follow the procedures defined below: 1.

Clean the Model 30 at least once a month. If your work environment is excessively dirty, clean the unit at least once weekly, or more often. Remove dust and dirt accumulations from the Model 30 exterior with a clean, soft bristle brush.

2.

Use a clean, soft cloth dampened slightly with a mild detergent and water solution to remove any dust and dirt that remains on the scan head after using the brush in step 1.

!

CAUTION

Warning: Never attempt any procedures that require the removal of the cover from the Scan Head housing.

WARNING: Avoid using chemicals that may harm plastic such as those that contain benzene, acetone and similar products. 3.

Clean the scan head laser exit window. If the exit window is obstructed in any way, the scan head will not be able to read codes. Lightly brush off particles of dirt using a soft, lint-free lens tissue, or “Dustoff” (compressed air in a can).

CAUTION: Use caution when cleaning the laser scan head. Avoid looking directly into the laser exit window while the laser is on. Do not allow any abrasive material to touch the window. Do not use commercial glass cleaners on the window; these leave a film that accelerates the accumulation of dirt. 4.

Check the Trigger Photoeye and reflector. Make sure the photoeye lens and the reflector are clean.

A recommended “One Month Preventive Maintenance Log” is provided on the next page. This log sheet identifies the daily, weekly, and monthly preventive maintenance procedures. Copy this sheet and use it to log the maintenance data for each scan head. If the scan head is located in a relatively clean environment, it may be necessary to complete these procedures only once a month. However, if the environment is excessively dirty, weekly execution of these procedures may be the key to reliable operation.

Accu-Sort Systems

Page 63

Basic Troubleshooting and Maintenance

5-3

ONE MONTH PREVENTIVE MAINTENANCE LOG MODEL 30 BAR CODE SCAN HEAD Serial Number: ___________

Scan Head Cleaning Procedures 1. Scan Head Enclosure

Week1 Week2 Week3 Week 4 _____ _____ _____ _____

2. Laser Exit Window

_____ _____ _____ _____

3. a. Trigger Photoeye

_____ _____ _____ _____ b. Reflector for Photoeye

_____ _____ _____ _____

The above was checked by: (please initial)

_____ _____ _____ _____

Maintenance Checks

Week1 Week2 Week3 Week4

1. a. Scan Head Mounting

_____ _____ _____ _____ b. Trigger Photoeye Mounting

_____ _____ _____ _____ c. Reflector Mounting

_____ _____ _____ _____

2. a. P1 Connections

_____ _____ _____ _____ b. P2 Connections

_____ _____ _____ _____

3. Visible scanning beam

_____ _____ _____ _____

4. Logic is decoding

_____ _____ _____ _____

The above was checked by: (please initial)

_____ _____ _____ _____

Model 30 Hardware Operations Manual

Page 64

Chapter 5

5-4

Flow Chart of General Maintenance Checks

Use the following chart when performing the general preventive maintenance steps outlined in this Chapter. If these steps are checked on a regular basis (at least once a week depending on the work environment) the Model 30 will continue to provide reliable operation. If your Model 30 is damaged, please contact our Customer Service Department at 1-800-BAR-CODE. Please refer to the Customer Service Section in the front of this manual for more information about your equipment.

HARDWARE CHECKS

IS THERE DUST ACCUMULATION ON THE LASER EXIT WINDOW?

CLEAN AS SPECIFIED IN CHAPTER 5

YES

NO ARE ALL MODEL 30 CONNECTIONS MADE?

CONNECT ALL CABLES

NO

YES DO GOOD READS OCCUR?

NO

IS THE CODE DAMAGED?

NO

YES

MAINTENANCE COMPLETED

CHECK ATTACHED LOGIC UNIT

YES

REPLACE CODE

Preventive Maintenance Flow Chart

Accu-Sort Systems

Page 65

Basic Troubleshooting and Maintenance

Basic Trouble Checks

5-5

If you have any problems with the Model 30, check the simple possibilities outlined in this section. If performing these checks do not solve the problem, you can request factory service from Accu-Sort. Accu-Sort Field Engineers are fully equipped and prepared to travel to customer sites to provide start-up assistance, training, and repair service. In addition, equipment can be returned to Accu-Sort for repair when necessary. WARNING: If you must service your own equipment, only a skilled technician who has gone through an Accu-Sort Training program for the Model 30 can perform any detailed troubleshooting. Accu-Sort cannot be held responsible for damages to the Model 30 or any device connected to the Model 30, etc. caused by improperly performed procedures or untrained personnel. (This will void any applicable warranty.) Successful troubleshooting depends upon knowledge of electronics and the availability of proper test equipment. Experience indicates that the best service comes from qualified Accu-Sort personnel. The Model 30 is designed for most service to be accomplished through the replacement of boards or modules. This increases scan head independence, and reduces the need to rely on outside service organizations. Be sure to direct any questions concerning the operation and service of the Model 30 to Accu-Sort Systems' Customer Service Department. Before doing so, please refer to the Customer Service Section of this manual.

Model 30 Hardware Operations Manual

Page 66

Chapter 5

5-6

Checking the Simple Possibilities Before making these checks, make sure the "POWER" LED is illuminated. A scanning beam of light should appear, leaving the exit window. Operate the unit as described in Chapter One. If the Model 30 will not read the bar codes that are properly located within the scan head window, check the following: • Is the power connection made? • Is a red beam of light visible in front of the exit window? When the Trigger PE is blocked, a sweeping red laser beam should be visible on an object placed in front of the scan head window. (Be sure the laser flip lid is not covering the laser exit window to block the laser beam!) • Is the scan head window clean? • Does the Trigger LED light when the Trigger PE is blocked? • Does the Trigger PE function properly? • Are all external connectors making tight connections? Check the connections to the Model 30. Also check the connections at the other end of each cable.

Accu-Sort Systems

Page 67

Chapter

6

Appendices

Chapter Contents Appendix A: Appendix B:

ASCII Communications ...................................... 6-1 ASCII Chart ........................................................ 6-13

Page 68

Chapter 6

Accu-Sort Systems

Page 69

6-1

Appendices

Appendix A: ASCII Communications

This protocol may not be available for every Accu-Sort device.

Standard RS485 Multidrop Communications RS485 communication is an Engineering Industries Association standard for the transmitters and receivers of a digital equipment interface. RS485 communication uses differential signal lines and allows for multiple transmitters on one signal pair (although only one transmitter may be enabled at any given time). This is a way of allowing one device to communicate with one or more other devices using a host-to-polled-device method. The Host-to-polled-device system works as follows: The host device (usually a decoder logic or computer) originates poll messages. The poll message is from the host to a polled device requesting the polled device to respond with data (if data is available). The polled device is usually a bar code scanner. The polled device responds to the polls from the host. It is not allowed to transmit unless it has been “asked” (polled) by the host. Shown below is a simplified drawing of one way that RS485 communications work: NOTE: This representation shows one host and six polled devices. You can ultimately have up to 32 polled devices for each serial port on the host (depending on the line length and required response time).

Polled Device HOST Polled Device Polled Device Polled Device Polled Device

Polled Device Model 30 Hardware Operations Manual

Page 70

6-2

Chapter 6

The remainder of this section defines the message formats and timing requirements for the protocol used on RS485 multidrop (2-wire) communications lines. The protocol is defined for both the “master” device and the “slave” devices. This protocol is defined for a onemaster system only. The following definitions may help you better understand this protocol. ASCII digit: This means the ASCII code for a single decimal digit. For example, 30h is the ASCII digit that encodes a zero. HEX digit: This means the ASCII code for a single hexadecimal digit. Some examples are: 35h is the code for a five, 42h is the code for a "B" (which equals 11 base 10), and the hexadecimal number "5A" would be encoded by the two HEX digits 35h and 41h.

Message Formats The standard communications parameters are as follows: Standard asynchronous data frame (least significant bit first) 7 data bits 1 even parity bit 2 stop bits If the master can only support 8 bit data plus a parity bit, then the format is as follows: 8 data bits 1 odd parity bit 1 stop bit (Odd parity is required to make sure that the guard character will be all ones with one for parity.) You can use any baud rate that is supported by both the master and the slaves. System performance is usually best when using the highest baud rate possible.

Accu-Sort Systems