Page 51

4-7

Using The Plus II Logic with Your Model 30

Connecting to Other Serial Devices You can connect the Plus II to many other serial devices. The drawings below show all the pin connections for the Plus II when using serial communications. If you need to create your own cables to wire your Plus II to another device, use these drawings as a guide. It is very important that you make the proper pin connections. Below is a list of terms used in these drawings: GND-Ground TXD-Transmit Data (RS232) CTS-Clear To Send (RS232) RD-Receive Data (RS422) SD- -Inverting Line (RS485) Send Data (RS422)

RXD-Receive Data (RS232) RTS-Request To Send (RS232) RD+ -Receive Data (RS422) SD+ -Non-inverting Line (RS485) Send Data (RS422)

!

CAUTION

RS232 With No Handshaking Be careful when you wire your own cable for the Plus II. You must make sure that the Plus II receives only 5 volts on pins 14 and 15.

Use the following drawing as a guide when you want to connect your Plus II to a device that is using RS232 communication with no handshaking:

PLUS II 1 TXD

6

HOST RXD

1 2 3

GND TXD RXD

S. GND RXD TXD

15 Recommended Cable Type: ALPHA # 5473C or Equivalent Maximum Cable Length: 50 Feet

RS232 With RTS/CTS Handshaking

You must enable communication types using the software. Refer to your ACUSETUP Manual for more information.

Use the following drawing as a guide when you want to connect your Plus II to a device that is using RS232 communication with RTS/CTS handshaking:

PLUS II

NOTE: E3 MUST BE OUT AND E2 MUST BE 2-3, 4-5

1

6

15

1 2 3 4 5

GND TXD RXD RTS CTS

HOST GND RXD TXD CTS RTS

Recommended Cable Type: ALPHA # 5473C or Equivalent Maximum Cable Length: 50 Feet

Model 30 Hardware Operations Manual

Page 52

4-8

Chapter 4

RS422 (point to point)

You must enable communication types using the software. Refer to your ACUSETUP Manual for more information.

Use the following drawing as a guide when you want to connect your Plus II to a device that is using RS422 serial communication: 220 Termination

PLUS II 1

1 8 6 7 9

15

6

220 Termination

GND SDSD+ RD+ RD-

HOST S. GND RDRD+ SD+ SD-

NOTE: Termination resistors may be placed in connector shell. The termination resistor value is 220 OHM 1/4 watt. With RS-422, the receive lines on both sides must be terminated. Cable Type: Alpha #5473C (or equivalent).

RS485 Multidrop - Half Duplex

Use the following drawing as a guide when you want to connect your Plus II to a device that is using RS485 Multidrop serial communication:

220 Termination (Polling Required)

PLUS II

HOST

1 1 6 8 6

15

1 6 8 1 6 8 1 6 8

S. GND SD+ SD-

GND SD+ SDGND SD+ SDGND SD+ SDGND SD+ SD-

220 Termination

NOTE: Termination resistors may be placed in connector shell. The termination resistor value is 220 OHM 1/4 watt. The transmit-receive lines on both sides must be terminated. Cable type: Alpha #5473C (or equivalent)

Accu-Sort Systems

Page 53

4-9

Using The Plus II Logic with Your Model 30

Current Loop

Use the following drawings as guides when you want to connect your Plus II to a device that is using Current Loop serial communication:

PLUS II ACTIVE 1

6

15

HOST PASSIVE 11 R+ 12 T14 I+ 1 GND 10 T+ 13 R15 I+

TR+ T+ R-

Recommended Cable Type: Alpha # 5473C or Equivalent Maximum Cable Length: 1000 Feet at 2400 Baud

PLUS II PASSIVE 1

6

15

ACTIVE 10 T+ 11 R+ 12 T13 R-

NOTE: I+ and I- should be current limited to 25mA Recommended Cable Type: Alpha # 5473C or Equivalent Maximum Cable Length: 1000 Feet at 2400 Baud

HOST I+ TR+ II+ IT+ R-

Model 30 Hardware Operations Manual

Page 54

4-10

Chapter 4

Cable Adapter Use the following drawings as guides when you want to make a cable adapter between an old plus serial cable and a new Plus II serial cable:

NEW PLUS II

OLD PLUS LOGIC 1

9

1 GND 2 TXD 3 RXD 4 SD+ 5 SDRD+ 6 RTS 7 RD8 9 CTS

GND 1 TXD 2 RXD 3 RTS 4 CTS SD+ 5 6 RD+ 7 SD8 RD-

9

1 GND 2 TXD 3 RXD 4 SD+ 5 SDRD+ 6 GND 7 8 RD9 V+

6

15

9

NEW PLUS II

OLD PLUS LOGIC 1

1

GND TXD RXD

1 2 3 4 SD+ 5 6 RD+ 7 SD8 RD9

1

6

Wiring diagrams for cable adapter between old Plus serial cable and new Plus 2. The adapter shell is DIY9MF. The wire is 22 AWG.

Accu-Sort Systems

15

Page 55

4-11

Using The Plus II Logic with Your Model 30

Connecting A Triggering Device to your Plus II Logic J2 is a nine pin (D) female connector on the Plus II. This connection is for a product detection device. You must use the cables with a nine pin (D) male connector on one end. The other end of the cables must have a comparable connector for the product detection device. To connect the Plus II to a trigger input cable, align the pins on the cable with the holes on connector J2. Insert the pins in the holes, and push until a tight connection is made. Turn the two slotted screws on each cable clockwise until tight. After these connections are properly made, connect the other end of the cable to the product detection device. Refer to page 4-4 for the pin configuration of the 9-pin connector (J2).

Model 30 Hardware Operations Manual

Page 56

4-12

Providing Power to your Plus II

If you are using a Plus Logic unit, issued before January 1, 1993, please make sure that you are using the proper DC Power Adapter and Communications Cable.

Chapter 4

The Plus II operates from a power source of +12V, +5V DC. Do not plug the DC Adapter into any power source until the unit is in position and all other connections are made. Do not use the Plus II power line to operate other equipment. Do not place the A.C. line in the same conduit as the serial communications cables. This would cause communication interference. To connect the power adapter to the Plus II, align the female notches on the power adapter jack with the male pins on the Plus II marked DC Input. When the two components are properly aligned, join the two of them together. After this connection is properly made, connect the other end of the power adapter cord to an AC outlet. To disconnect the DC input, squeeze the sides of the connector and pull it straight from the unit.

POWER SUPPLY

MODEL 30 SCAN HEAD

PLUS LOGIC

VIBRATING VANE ASSEMBLY

110VAC- Part #3027 220VAC- Part #3027A

ALLOWABLE INPUT VOLTAGE RANGE V+ @ 11.O TO 14.0 VDC

IL 200mA MAX

+

IS 600mA MAX

+

IV 200mA MAX

=

IT 1000mA MAX

NOTES: 1) ACTUAL CURRENTS ARE DEPENDENT ON SUPPLY VOLTAGE V+ 2) IS IS A FUNCTION OF SCAN RATE. (I S MIN = APPROX. 400mA @ MIN SCAN RATE) 3) IV IS A FUNCTION OF VANE PERIOD. (IV MIN = APPROX. 100 mA @ MIN VANE PERIOD)

Power Requirements

Accu-Sort Systems

Page 57

4-13

Using The Plus II Logic with Your Model 30

Plus II Visual Diagnostics

The Plus II has three status LED indicators on the top of the cover panel, as shown below. Use these LED's for diagnosing or troubleshooting any errors that may occur in your application.

INC.

D RX D TX LE ID

P L U S D E C O D E R ACCU-SORT SYSTEMS, 1A @ 12VDC

D

RX

D

TX

LE

ID Below is a description of each LED:

IDLE- (Yellow) This LED remains off for a 5 second duration when the unit is turned on, but blinks when the unit is operating. When the unit is in the setup mode, this LED blinks alternately with the DECODE LED on the Model 30. TRANSMIT- (Green) This LED lights when the unit is transmitting data. RECEIVE- (Red) This LED lights when the unit is receiving data.

Model 30 Hardware Operations Manual

Page 58

4-14

Chapter 4

Notes

Accu-Sort Systems

Page 59

Chapter

5

Maintaining And Troubleshooting Your Model 30

Chapter Contents Introduction ..................................................................................... 5-1 General Cleaning and Maintenance............................................. 5-2 Flow Chart of General Maintenance Checks .............................. 5-4 Basic Trouble Checks ..................................................................... 5-5 Checking the Simple Possibilities ................................................ 5-6

Page 60

Chapter 5

Accu-Sort Systems