The text of a manual · part 5 of 8
Model 22 Series II Bar Code Scanner Operations and Maintenance Manual, pages 41 to 50
Pages 41 to 50 of 76
The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort Model 22
Page 41
MAKING CONNECTIONS TO YOUR MODEL 22 SERIES II
3-9
CONNECTING YOUR MODEL 22 SERIES II TO A PC Accu-Sort recommends that you purchase the programming kit for your Model 22 Series II. This kit provides you with the cables that you need to connect your Accu-Sort device to a PC. If you would like to purchase the programming kit, call the Accu-Sort Customer Service Department at (215) 723-0981 with the following information: Part Name Model 22 Series II Programming Kit
Part Number 1000001199
Model 22 Programming Kit To connect your Model 22 Series II to most PCs using the programming kit: 1. Plug in the 15-pin connector on the programming kit cable labeled P1 to either 15-pin connector (J1 or J3) on the back of your Model 22 Series II. 2. Plug in the 9-pin connector end of your programming kit cable labeled PC to a 9-pin serial port on your PC. 3. Use a small standard slotted screwdriver to tighten the screws on the strain reliefs at both ends.
Solutions with Vision
Page 42
3-10
MODEL 22 SERIES II OPERATIONS AND MAINTENANCE MANUAL
CONNECTING TO A PC WITHOUT THE PROGRAMMING KIT If you choose not to purchase the Model 22 Series II Programming Kit, you need to make your own cables. The following pinout diagrams show typical RS232 communication cable pin connections from your PC to your Model 22 Series II with connector and cable specifications. Item
Accu-Sort Part Numbers
15-pin connector 9-pin connector Cable 15-pin & 9-pin strain relief
1000012239 (or equivalent) 1000015249 (or equivalent) 1000009323 (or equivalent) 1000016537 (or equivalent)
NOTE: All connectors are shown from the soldering side. Standard 9 Pin PC Connector
9 Pin Female "D"
15 Pin Female "D" 1
1
9
Model 22 (J1 or J3)
PC
25 Pin Female "D"
Standard 25 Pin PC Connector
15
15 Pin Female "D"
TXD
1
6
1
RXD
25
PC
Model 22 (J1 or J3)
Model 22 Series II to PC Connections
Accu-Sort Systems
6
15
Page 43
MAKING CONNECTIONS TO YOUR MODEL 22 SERIES II
3-11
CONNECTING YOUR MODEL 22 SERIES II TO A TERMINAL If you are using a TERMINAL to program your Model 22 Series II, you need to make your own cables. The pin-out diagrams below show typical RS232 communication cable pin connections from your TERMINAL to your Model 22 Series II and connector and cable specifications. These pin connections are correct for most Terminals. Your TERMINAL may be different. Before you begin making your cable, check your TERMINAL documentation to make sure these pin connections are accurate.
Item 15-pin connector, female 25 pin connector, male Cable 25-pin strain relief, metallic shell 15-pin strain relief, metallic shell
Accu-Sort Part Number 1000012239 (or equivalent) 1000015223 (or equivalent) 1000009323 or 1000017397 (or equivalent) 1000016539 (or equivalent) 1000016537 (or equivalent)
NOTE: All connectors are shown from the soldering side. 25 Pin Male "D"
Standard 25 Pin CRT Connector
15 PIn Female "D"
25 1
1
CRT
Model 22 (J1 or J3)
6
15
TERMINAL to Accu-Sort Device Connections
Solutions with Vision
Page 44
3-12
MODEL 22 SERIES II OPERATIONS AND MAINTENANCE MANUAL
CONNECTING A TRIGGERING DEVICE TO YOUR MODEL 22 SERIES II The trigger connector on the Model 22 Series II is a 9-pin "D" female, labeled TRIG (J2). Use this connector to connect hardware detection input; such as a photoeye to the Model 22 Series II. You can plug a standard photoeye directly in J2, or you can use the drawing below that shows the internal circuitry of the trigger input, to wire another triggering device: +5V
RESET
621-STR-073-009 J2
To/From Photoeye
2.2K
2.2K
74HC132
TRIGGER TRIGGER GND V+ II+ GND
56K V+
4N37 TRIGGER 2.2k
56K
860 OHM
74HC132
Internal Wiring for Model 22 Series II Trigger (J2) Connection
The following drawings represent some common triggering inputs the Model 22 Series II uses.
Normally Open
DEM-9P P2 J2 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9
Trigger Trigger GND V+ II+ GND TACH ANLG CODE
Dry Contacts: Minimum current rating = 1mA or less Contact bounce = 5mS or less
Wiring Your Model 22 Series II to a (Form A) Triggering Input
Accu-Sort Systems
Page 45
MAKING CONNECTIONS TO YOUR MODEL 22 SERIES II
NORMALLY CLOSED
3-13
DEM-9P P2 J2 1 1 TRIGGER 2 2 TRIGGER 3 3 GND
NORMALLY OPEN
4 4 V+ 5 5 I6 6 I+ GND 7 7 8 8 TACH 9 9 ANLG CODE
Wiring Your Model 22 Series II to a (Form C) Triggering Input
DEM-9P
-
Normally 0V or open +
P2 J2 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9
Trigger Trigger GND V+ II+ GND TACH ANLG CODE
Wiring Your Model 22 Series II to a (5-24 Volt Optically Isolated) Triggering Input
Normally High
74XX
DEM-9P P2 J2 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9
Trigger Trigger GND V+ II+ GND TACH ANLG CODE
22 scanner represents approximately 2 TTL loads
Wiring Your Model 22 Series II to a (TTL) Triggering Input
Solutions with Vision
Page 46
3-14
MODEL 22 SERIES II OPERATIONS AND MAINTENANCE MANUAL
DEM-9P P2 J2 1 1 2 2 3 3 4 4 5 5
Normally Off
6 6 7 7 8 8 9 9
Trigger Trigger GND V+ II+ GND TACH ANLG CODE
Wiring Your Model 22 Series II to a NPN Transistor Triggering Input
Normally Off
DEM-9P P2 J2 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9
Trigger Trigger GND V+ II+ GND TACH ANLG CODE
Wiring Your Model 22 Series II to a PNP Transistor Triggering Input
Accu-Sort Systems
Page 47
MAKING CONNECTIONS TO YOUR MODEL 22 SERIES II
3-15
CONNECTING YOUR MODEL 22 SERIES II TO THE INTERFACE BOX Then you connect your Model 22 Series II to the Accu-Sort Small Scanner Interface Box, it is recommended that you use the interconnect cable provided with your interface box as shown below:
Model 22 Programming Kit Interconnect Cable
This cable has two 15-pin "D" connectors. Connect the female end of the cable to the 15-pin "D" male connector on the rear of the Model 22 Series II, and tighten the screws with a small flat head screwdriver. Connect the other end of the cable to the 15-pin "D" female connector labeled SCANNER J1 on the interface box, and tighten the screws with a small flat head screwdriver. Every time a Small Scanner Interface Box is used with a Model 22, transformer W48D-J1000-5/1 is not to be used. Both the Model 22 and the interface box will be powered by the Model 22 power supply, using cable assemblies MDL22-17A or MDL22-17B.
IF THE INTERCONNECT CABLE IS NOT AVAILABLE If you do not have the interconnect cable, you need to create one. The following drawing shows the pin connections for the 15-pin "D" male connector on the Model 22 Series II and the 15-pin "D" female connector on the interface box. The maximum length of this cable is 30 feet.
Solutions with Vision
Page 48
3-16
MODEL 22 SERIES II OPERATIONS AND MAINTENANCE MANUAL Note: Connectors are shown from the soldering side The shield is electrically connected to both cable shells.
Interface Box End of Cable (15 pin "D" male)
Model 22 End of Cable J1 or J3 (15 pin female "D")
Pin Connections for Connections Between The Interface Box and the Model 22 Series II
Accu-Sort Systems
Page 49
MAKING CONNECTIONS TO YOUR MODEL 22 SERIES II
3-17
USING MODEL 22 SERIES II PARALLEL OUTPUTS The Model 22 Series II has two parallel outputs; NVC/NO MATCH and GO/MATCH. These outputs are activated or deactivated from pin 4 and pin 5 respectively on the Model 22 Series II 15-pin connector. Both of these are controlled by software. (Refer to your Accu-Setup Small Scanner Module Programming Manual.) You can use these outputs to have a beeper sound when you receive a no read or no match (when used as a verifier), or you could have a light turn on every time there is a go (good read) or match (when used as a verifier). There are many other uses for these outputs. When you connect these pins to the small scanner interface box, they control the relays in the box.
HOW THE OUTPUTS WORK The names of the two outputs directly reflect their purpose. The NVC/NO MATCH output changes its electrical state dependent on receiving a no read or a no match (while in verifier mode). The GO/MATCH output changes its electrical state dependent on receiving a good bar code or a match (while in verifier mode). For example, if you set the NVC/NO MATCH timer for 150 milliseconds, every time the scanner sees a non-valid bar code the NVC/NO MATCH timer signals until that 150-millisecond time period is complete.
Solutions with Vision
Page 50
3-18
MODEL 22 SERIES II OPERATIONS AND MAINTENANCE MANUAL
PARALLEL OUTPUT CONNECTIONS The following diagrams show the proper connections that you need to ensure that the output function properly. If you use the interface cable to connect the Model 22 Series II to the Small Scanner Interface Box, you do not need to make any other connections. Model 22 (J1 Only) NVC/NOMATCH 1
4
1
GND
4
OUT 0 Load +
+
Model 22 (J1 Only) GO/MATCH 5
1
1
GND
5
OUT 1 Load +
+
Output Connections
The table below defines some basic terminology. The drawing below shows the schematic of the output timer’s circuitry:
Software NVC/No Match Go/Match
Model 22 J1 Only 4
Model 20
Interface Box
OUT 0 = OUT 1 =
Relay 1 Relay 2
+5V
OUT 0
5
10K
820 OHM
10K
Pins
2 TTL Outputs (Optional CTS)
0 4 OUT OUT 1/CTS 5 3
3 to 7 KOHM RS232 IC
2
1
OUT 1 820 OHM
The Model 22 Series II Output Circuitry
Accu-Sort Systems