Page 31
START UP AND OPERATION
2-7
SETTING UP YOUR MODEL 22 SERIES II The steps below represent one recommended scenario to set up your Model 22 Series II Scanning System: 1. Remove all materials from the box. 2. Check the materials against the packing list and make sure everything is there. 3. Make sure none of the parts are broken. 4. Make all the appropriate connections to your Model 22 Series II as explained in Chapter Three. 5. If you need to make any programming changes to your Model 22 Series II, connect your Model 22 Series II to a PC or CRT as described in Chapter Three of this manual, and refer to your Accu-Setup Small Module Programming Manual. 6. Mount your Model 22 Series II as described in Chapter Two. 7. Startup the scanner. IMPORTANT: Wait at least 30 seconds before attempting to enter the Setup Mode. 8. Begin reading your bar codes. If you have any problems or questions concerning setting up your Model 22 Series II, contact Accu-Sort immediately. Refer to the Customer Service Section of this manual.
Solutions with Vision
Page 32
2-8
Accu-Sort Systems
MODEL 22 SERIES II OPERATIONS AND MAINTENANCE MANUAL
Page 33
Chapter Three Making Connections to Your Model 22 Series II
3Heading 2
Chapter Three
Contents
INTRODUCTION .......................................................................................... 3-2 MAKING CONNECTIONS TO YOUR MODEL 22 SERIES II ............................... 3-2 SUPPLYING POWER TO YOUR MODEL 22 SERIES II .................................... 3-4 USING ACCU-SORT'S LOCAL POWER SUPPLY FOR POWER ..................... 3-4 WIRING OTHER SOURCES OF POWER DIRECTLY ..................................... 3-5 MAKING COMMUNICATION CONNECTIONS TO OTHER EXTERNAL DEVICES ... 3-6 RS232 WITH NO HANDSHAKING ............................................................. 3-6 RS232 WITH RTS/CTS HANDSHAKING .................................................. 3-6 RS422 (POINT TO POINT) ....................................................................... 3-7 RS422 (FOUR WIRE MULTIDROP) .......................................................... 3-7 RS485 MULTIDROP (2 WIRE) ................................................................. 3-8 CONNECTING YOUR MODEL 22 SERIES II TO A PC .................................. 3-9 CONNECTING TO A PC WITHOUT THE PROGRAMMING KIT ...................... 3-10 CONNECTING YOUR MODEL 22 SERIES II TO A TERMINAL .................. 3-11 CONNECTING A TRIGGERING DEVICE TO YOUR MODEL 22 SERIES II ...... 3-12 CONNECTING YOUR MODEL 22 SERIES II TO THE INTERFACE BOX............. 3-15 IF THE INTERCONNECT CABLE IS NOT AVAILABLE ................................. 3-15 USING MODEL 22 SERIES II PARALLEL OUTPUTS ..................................... 3-17 HOW THE OUTPUTS WORK................................................................... 3-17 PARALLEL OUTPUT CONNECTIONS ....................................................... 3-18
Page 34
3-2
MODEL 22 SERIES II OPERATIONS AND MAINTENANCE MANUAL
INTRODUCTION This chapter explains how to supply power to your Model 22 Series II, and how to connect your Model 22 Series II to a PC and TERMINAL. This chapter also explains how to connect a photoeye, tachometer, and interface box to your Model 22 Series II. You must make these connections before you can begin setting up or using your Model 22 Series II.
MAKING CONNECTIONS TO YOUR MODEL 22 SERIES II There are four connectors on the rear of the Model 22 Series II. There are two serial communications ports, one power port, and one trigger port. The following are the port definitions on the Model 22 Series II connector panel: • J1 (COM1) - 15-pin male 'D' connector (serial port) • J2 (Trigger) - 9-pin female 'D' connector • J3 (COM2) - 15-pin male 'D' connector (serial port) • J4 (Power) - 5 pin EuroFast connector
Refer to the drawing to the right. It shows the Model 22 Series II connector panel and details the pins for each 'D' connector. Refer to the Wiring Other Sources of Power Section of this chapter for the pin definitions of the J4 power connector.
Accu-Sort Systems
Page 35
MAKING CONNECTIONS TO YOUR MODEL 22 SERIES II
3-3
Model 22 Series II Rear Connector Panel with Pin Definitions
Solutions with Vision
Page 36
3-4
MODEL 22 SERIES II OPERATIONS AND MAINTENANCE MANUAL
SUPPLYING POWER TO YOUR MODEL 22 SERIES II You must supply power to the Model 22 Series II through the 5-pin “DIN” female connector at the rear of the unit labeled J4, or you wire power directly into J1 or J3. You can supply power using one of the following two methods: using one of the Accu-Sort local power supplies, or wiring power directly into the Model 22 Series II using one of your own methods. The Model 22 Series II must meet the following three requirements regardless of the method that you use to supply power: • +5VDC ±0.25V @ 500 mA must be supplied • +12VDC ±0.6V @ 500 mA must be supplied • Ground must be supplied • Metal shell of all connectors must be grounded
USING ACCU-SORT'S LOCAL POWER SUPPLY FOR POWER You can use the Accu-Sort 110V AC or the 220V AC local power supplies to supply power to the Model 22 Series II five pin "EuroFast" connector. These power supplies are shown below:
Accu-Sort 110V AC power supply (left) and 220V AC power supply (right)
If you use one of these power supplies, you need to plug the five pin male connector in the J4 connector at the rear of the Model 22 Series II. Then plug in the other end of the AC power cord to the appropriate grounded wall outlet. This power supply must be grounded electrically. Ensure your AC power outlet has a properly grounded receptacle. Also, make sure you have the appropriate power cord for your country before powering the unit.
Accu-Sort Systems
Page 37
MAKING CONNECTIONS TO YOUR MODEL 22 SERIES II
3-5
WIRING OTHER SOURCES OF POWER DIRECTLY To supply power to the Model 22 Series II five-pin connector, you can use many other sources than those previously mentioned. You must comply with the Model 22 Series II power requirements, mentioned in the beginning of this section, to ensure proper operation. The drawings below show alternate ways of wiring power into the Model 22 Series II: Model 22 (Power) 1
2
4 5
J4 POWER +12V 1 +5V 2 GND 3 GND 4 Chassis GND 5
3
Alternative Wiring Methods for Supplying Power to the Model 22 Series II Solutions with Vision
Page 38
3-6
MODEL 22 SERIES II OPERATIONS AND MAINTENANCE MANUAL
MAKING COMMUNICATION CONNECTIONS TO OTHER EXTERNAL DEVICES The Model 22 Series II is versatile when you need to connect to other devices. The drawings below show all the pin connections for the Model 22 Series II when using serial communications on port J1 or J3. If you need to create your own cables to wire your Model 22 Series II to another device, use these drawings as a guide. It is very important that you make the proper pin connections. Use Accu-Sort mating connector (PN 1000012239) or equivalent 15-pin female connector. Below is a list of terms used in these drawings: GND TXD CTS RD SD
Ground Transmit Data(RS232) Clear To Send (RS232) – J3 only Received Data (RS422) Inverting Line (RS485) Send Data (RS422)
RXD RTS RD+ SD+
Receive Data (RS232) Request To Send (RS232) – J3 only Receive Data (RS422) Non-inverting Line (RS485) Send Data (RS422)
RS232 WITH NO HANDSHAKING Use the following drawing as a guide when you want to connect your Model 22 Series II to a device that is using RS232 communication with no handshaking: NOTE: All connectors are shown from the soldering side. Model 22 (J1 or J3)
HOST
Recommended Cable Type: ALPHA # 5473C or equivalent Maximum Cable Length: 50 feet
RS232 WITH RTS/CTS HANDSHAKING (J3 ONLY) RS232 with RTS/CTS handshaking is available on the J3 port only. Use the following drawing as a guide when you want to connect your Model 22 Series II to a device that is using RS232 communication with RTS/CTS handshaking: NOTE: All connectors are shown from the soldering side. Model 22 (J3 only)
Recommended Cable Type: ALPHA # 5473C or equivalent Maximum Cable Length: 50 feet
Accu-Sort Systems
HOST
Page 39
MAKING CONNECTIONS TO YOUR MODEL 22 SERIES II
3-7
RS422 (POINT TO POINT) Use the following drawing as a guide when you want to connect your Model 22 Series II to a device that is using RS422 serial communication: NOTE: All connectors are shown from the soldering side. 220 Termination
Model 22 (J1 or J3) 1
1 6 8 7 9
15
6
220 Termination
GND SD+ SDRD+ RD-
HOST S. GND RD+ RDSD+ SD-
NOTE: Termination resistors may be placed inside the connector strain relief. The termination resistor value is 220 OHM 1/4 watt. With RS-422, the receive lines on both sides must be terminated. CABLE TYPE: ALPHA #5473C (OR EQUIVALENT).
RS422 (FOUR WIRE MULTIDROP) Use the following drawing as a guide when you want to connect your Model 22 Series II to a device that is using Four Wire Multidrop communications:
NOTE: All connectors are shown from the soldering side. 220 Termination
Model 22 (J1 or J3) 1
6
15
End of the line
1 6 8 7 9
GND SD+ SDRD+ RD-
1 6 8 7 9
GND SD+ SDRD+ RD-
HOST S. GND RD+ RDEnd of the line SD+ SD-
220 Termination
NOTE: Termination resistors may be placed inside the connector strain relief. The termination resistor value is 220 OHM 1/4 watt. With RS-422, the receive lines on both sides must be terminated. CABLE TYPE: ALPHA #5473C (OR EQUIVALENT).
Solutions with Vision
Page 40
3-8
MODEL 22 SERIES II OPERATIONS AND MAINTENANCE MANUAL
RS485 MULTIDROP (2 WIRE) Use the following drawing as a guide when you want to connect your Model 22 Series II to a device that is using RS485 Multidrop serial Communication: NOTE: All connectors are shown from the soldering side. 220 Termination
Model 22 (J1 or J3)
(Polling Required)
6
HOST End Of The Line
1
15
End Of The Line
1 6 8
GND SD+/RD+ SD-/RD-
1 6 8
GND SD+/RD+ SD-/RD-
1 6 8
GND
S. GND SD+/RD+ SD-/RD-
SD+/RD+ SD-/RD-
220 Termination
NOTE: RS485 allows for communication across the same lines Termination resistors can be placed inside the connector strain relief. The termination resistor value is 220 OHM 1/4 watt. The transmit-receive lines on both sides must be terminated.
Cable type: Alpha #5473C (or equivalent)
Accu-Sort Systems