Page 51

Chapter Four Maintenance And Troubleshooting

4Heading 2

Chapter Four

Contents

INTRODUCTION .......................................................................................... 4-2 CLEANING PROCEDURE ............................................................................. 4-2 TROUBLESHOOTING YOUR MODEL 22 SERIES II ......................................... 4-3 PROBLEM/SOLUTION LIST ......................................................................... 4-4

Page 52

4-2

MODEL 22 SERIES II OPERATIONS AND MAINTENANCE MANUAL

INTRODUCTION The Model 22 Series II hardware was specifically designed for the tough industrial environment. The unit does not need anything more than some basic cleaning and check-ups every month, depending on the harshness of your environment. This chapter provides you with a cleaning procedure and some troubleshooting techniques.

CLEANING PROCEDURE The Model 22 Series II enclosure is tightly sealed to prevent dust or dirt from entering the unit. Nothing inside of the Model 22 Series II needs to be cleaned on a regular basis. If the Model 22 Series II needs repair, do not open the unit. The Model 22 Series II is to be shipped back for repair. Refer to the Customer Service Section of this manual. To clean the Model 22 Series II: 1. Slightly dampen a lint-free cloth with a solution made of mild detergent and water. 2. Gently wipe the enclosure of the Model 22 Series II. Be careful to avoid the exit window. 3. Dry the enclosure of the Model 22 Series II with a dry lint-free cloth. To clean the Model 22 Series II exit window: 1. Dampen a lint-free tissue with distilled water and wipe off any dust particles. 2. Dry the exit window with a dry lint-free tissue.

Accu-Sort Systems

Page 53

MAINTENANCE AND TROUBLESHOOTING

4-3

TROUBLESHOOTING YOUR MODEL 22 SERIES II Use the following chart to help troubleshoot the Model 22 Series II. If your Model 22 Series II is damaged, please contact our Customer Service Department at 1-800-BAR-CODE. Please refer to the Customer Service Section in the front of this manual for more information about your equipment.

The Model 22 Series II status LED blinks for the first five seconds. If the unit is in continuous read mode, the LED turns solid amber, and the laser is activated.

Solutions with Vision

Page 54

4-4

MODEL 22 SERIES II OPERATIONS AND MAINTENANCE MANUAL

PROBLEM/SOLUTION LIST The following is a list of events that can occur with your scanning system. Below each event has a cause and solution.

Problem

Cause

The Status LED turns red for and extended period of time or it blinks There is no laser beam exiting from the scanner when power is supplied The Model 22 Series II is not reading bar codes

The Model 22 Series II detects a failure.

Call Accu-Sort Customer Service

No power is applied to the Model 22 Series II.

Check to ensure power is plugged in and power is applied to the interface connector. Enable code type or correct code length

Model 22 Series II has poor read rate

Model 22 Series II has poor read rate in hardware trigger Model 22 Series II has poor read rate in serial trigger No communication to host

Accu-Sort Systems

Code type is not enabled or wrong code length Model 22 Series II window is dirty, label is not within reading range, or label quality is poor. Photoeye not adjusted, or it is misaligned. Serial trigger is not timed properly with the arrival of the bar code. Host communication to scanner does not match

Solution

Clean Model 22 Series II window, check reading range or label, or check code quality.

Adjust the photoeye

Adjust the timing of your serial trigger so it turns on before the bar code and turns off after the bar code. Connect the Model 22 Series II to a PC and use ACCU-SETUP SMALL SCANNER MODULE PROGRAMMING MANUAL to confirm communications parameters. Make sure baud rate is set no higher than 38.4K.

Page 55

Appendices

AHeading 2

Appendix A

Contents

APPENDIX A – ASCII COMMUNICATIONS ...................................................A-2 STANDARD RS485 MULTIDROP COMMUNICATIONS ................................A-2 APPENDIX B: ASCII CHART ....................................................................A-13 APPENDIX C: READ CHARTS ..................................................................A-14 MODEL 22 SERIES II A – STANDARD OPTICS .......................................A-14 MODEL 22 SERIES II B – HIGH DENSITY OPTICS ..................................A-15 MODEL 22 SERIES II C – HIGH SPEED OPTICS .....................................A-16 MODEL 22 SERIES II D – LONG RANGE OPTICS ...................................A-17

Page 56

A-2

MODEL 22 APPENDICES

APPENDIX A – ASCII COMMUNICATIONS STANDARD RS485 MULTIDROP COMMUNICATIONS RS485 communications is an Engineering Industries Association standard for the transmitters and receivers of a digital equipment interface. RS485 communication uses differential signal lines and allows for multiple transmitters on one signal pair (although only one transmitter may be enabled at any given time). This is a way of allowing one device to communicate with one or more other devices using the Master/Slave method. The Host to polled device system works as follows: The host device (usually a decoder logic or computer) originates poll messages. The poll message is a message from the host to a polled device requesting the polled device to respond with data (if data is available). The polled device is usually a bar code scanner. The polled device responds to the polls from the host. It is not allowed to transmit unless it has been "asked" (polled) by the host. Shown below is a simplified drawing of one way that RS485 communications works: This representation shows one host and six polled devices. You can ultimately have up to 32 polled devices for each serial port on the host (depending on the line length and required response time).

Polled Device HOST Polled Device

Polled Device

Polled Device

Polled Device

Polled Device

Accu-Sort Systems

Page 57

A-3

The remainder of this section defines the message formats and timing requirements for the protocol used on RS485 multidrop (2-wire) communications lines. The protocol is defined for both the "master" device and the "slave" devices. This protocol is defined for a one-master system only. The following definitions may help you understand this protocol a little better. ASCII digit: This means the ASCII code for a single decimal digit. For example,

30h is the ASCII digit that encodes a zero. HEX digit: This means the ASCII code for a single hexadecimal digit. Some examples are, 35h is the code for a five, 42h is the code for a "B" (which equals 11 base 10), the hexadecimal number "5A" would be encoded by the two HEX digits 35h and 41h. Message Formats

The standard communications parameters are as follows: Standard asynchronous data frame (least significant bit first) 7 data bits 1 even parity bit 2 stop bits If the master can only support 8 bit data plus a parity bit, then the format is as follows: 8 data bits 1 odd parity bit 1 stop bit (Odd parity is required to make sure that the guard character will be all ones with one for parity.) You can use any baud rate that is supported by both the master and the slaves. System performance is usually best when using the highest baud rate possible.

IMPORTANT: Although Accu-Setup for Small Scanners allows for a maximum baud rate setting of 57.6K, the Model 22 Series II communications baud rate is limited to 38.4K. Setting the Model 22 Series II communications baud rate higher than 38.4K will result in communications failure.

Solutions with Vision

Page 58

A-4

MODEL 22 APPENDICES

The following is framing for all messages sent by any device on the multidrop line: 0FFH

STX

ID(2)

TYPE(2)

SEQ

DATA LRC(2)

CR

(FFhex) = Guard Character

This character is "sacrificed" to the line noise that occurs when the unit transmitter is first turned on. The unit software may (optionally) wait one character time between transmitter enable and transmission of the STX (the next character). This eliminates transmitting the guard character. The receiver ignores this character. STX (02hex) = Start of text character

This character indicates the start of a message. The receiver should clear any characters in its receive buffer whenever it receives this character. ID (2 ASCII digits) = The unit ID

This field indicates the unit identification number of the unit to which the message is directed, if the message is coming from the master. This field indicates the unit identification number of the unit transmitting the message, if the message is from a slave. A message with an ID of "00" from the master is a broadcast message. All slave units should act on the message (display data, reset, etc.), but no slave should respond to the message. TYPE (2 ASCII digits) = The message type

This field describes the purpose of the message that is sent. There are five message types as shown below: Message Types

Accu-Sort Systems

01

Poll

02

Data

03

ACK

04

Wake up

05

No data

This message type is sent by the master unit to request data from a slave. This message type is sent by either a master to transfer data to a slave or by a slave to transfer data to the master after receiving a poll. The TYPE field will then be followed by a SEQ field and a data field. This message type is sent by the unit that has just received a valid data message. This message type is sent by the master. The slave that receives it should acknowledge the message. This message type may be sent by a slave indicating that the slave has no data to send in response to a poll. This message is optional. If the slave has no data, it may ignore the poll.

Page 59

A-5 SEQ (1 ASCII digit) = The sequence number

This field starts at zero at power up, and is incremented by one for each data message sent. When the sequence number reaches nine, it wraps around to one. This field is only present in a data message. DATA = The content of the data field

This field contains data, if the message type indicates that data is included. This field may contain no characters (length of zero; poll, acknowledge and wake up messages do not have data fields.) LRC (2 HEX digits) = The Linear Redundancy Check Sequence

The LRC is computed by exclusive-oring all the characters in the ID, TYPE, SEQ, and data fields, then converting the hex number into two HEX digits. This mathematical process allows the message to be checked for validity by the receiver. CR (0Dh) = Carriage return

This character indicates the end of the message. When this character is received, the unit should check to see that the message started with a STX, and check that the LRC is correct before accepting it as a valid message. Message Sequencing

The master unit initiates all data transfers by either sending data to a slave or requesting data from a slave. This protocol is strictly half duplex; only one device may be transmitting at any time. A slave device should not transmit unless it receives a valid message that requires a response--when it does receive such a message, it must respond quickly (See Timing). The master unit should respond in a timely manner, but is not under the same constraints as a slave. The following is the example of processing a Master/Slave interaction: Master 1. Wake up 2. Poll 3. Poll 4. Poll 5. Data

Slave’s response

Master’s response

ACK Data No data -noneACK

-noneACK -none-none-none-

Solutions with Vision

Page 60

A-6

MODEL 22 APPENDICES Timing

If a slave unit is going to respond to a poll from the master, it must start its response within two character times of the end of the carriage return at the end of the poll. This makes the response time dependent upon the baud rate.

The slave must turn on its transmitter within two character times after receiving the CR of the master’s poll. The slave must place the STX at the beginning of its response, into its serial port no later than three character times after receipt of the master’s carriage return. Once the slave begins transmitting, it must not allow a gap of more than one half a character time between characters. Most transmissions will take place under interrupt, so this should not be a problem; however, it means that serial port interrupts may not be disabled for an extended period of time during data transmission. Master: RTS TXD

Time:

S0123456Ps (CR) B C

A

Slave: RTS TXD

S0123456PsS0123456Ps_________S01 (FFh) (STX)

"S" is the start bit, "0123456" are the character bits, "P" is the parity bit and "s" is the stop bit. Typically, the "RTS" line is used to control the transmitter. In this diagram, "RTS" is high when the transmitter is enabled and low when the transmitter is disabled ("tri-stated"). The slave’s “FF” may be replaced with a 1 character time (10/ baud rate) delay between transmitter turn-on and transmission of the STX.

Time Limits:

A B

C

Accu-Sort Systems

Maximum: 2 character times (20/baud rate) Minimum: 0 Maximum: 4 character times (40/baud rate) Minimum: 2 character times (due to guard Character + STX transmission time) Maximum: 1/2 character time (5/baud rate) Minimum: 0