For the Accu-Sort Model 10

Page 21

INTRODUCTION

1-9

BLOCK DIAGRAM OF MODEL 10 SYSTEM

Bottom Label of Model 10 with Model Configuration

Solutions with Vision

Page 22

1-10

MODEL 10 OPERATIONS AND MAINTENANCE MANUAL

PRODUCT SPECIFICATIONS Physical Features Enclosure Size

Cabling Mounting Visual Diagnostics

User Input

Die-cast zinc O-ring seal meets NEMA 4, IP65 Environmental specifications Length 1.8 in (46 mm) Width 2.25 in (57 mm) Height 1.3 in (33 mm) Pigtail cable with zero clearance requirement. Does not contribute to length, width, or height Two M2.5 threaded thru holes (metric threads provide clearance for #2-56X1.5) Optional stainless steel bracket and conversion brackets for competitive products Power LED Indicates voltage is within specified limits Transmit/Receive LED Shows serial port activity and direction Status LED Blinks green, yellow, or red, indicating software activity, and whether errors have been logged Trigger/GO/NVC LED Shows status of read cycle 5 segment LED bar graph Displays real time performance information Scanning Efficiency (Good scans/100) Read Rate (Good reads/Trigger cycles) Single pushbutton to scroll through available diagnostics

Performance Features Ambient temperature range Laser diode light source Scan Rate Decoder Motor Mirror wheel Input power Serial interfaces, 115.2K baud (max) I/O

Precision beam exit properties Large scan angle Optical throw

32° – 120° F (0° – 50° C)

650 nM, 2 mW peak 200-300 scans per second Self contained (linear) Brushless DC motor Polygon scanning element, machined aluminum, 6 facets Single 5 volt or 10 to 30 Volt power supply (separate versions) Polarity and over-voltage protected RS232 with RTS/CTS support RS485 Multidrop RS422 Half-duplex (2 wire only) Trigger input: ±4.5 to 30 Volt, Opto-isolated 2 outputs: Solid state relays, Opto-isolated, short circuit protected, user selectable sink or source Beam exit angle parallel to mounting surface ±.050 in. (1.3 mm) throughout depth of field Unintentional raster less than ±.050 in. (1.3 mm) at far distance ±40° usable scan angle Scan coverage 4.5 in. (114 mm) minimum @ 2 in. (50 mm) distance 5 in. (127 mm) maximum for 10 mil bar code 8 in. (203 mm) maximum for 20 mil bar code

Model 10 Dimensions

Accu-Sort Systems

Page 23

INTRODUCTION

1-11 Do not turn on the system until all components are properly cabled and grounded with three-conductor AC power cords. Do not use a two-prong adapter. Do not use an extension cord to defeat the ground.

FEATURES • Installation simplified • Predictable beam exit (parallel to mounting surface) • Input voltage, pin-out labeled on unit • Unit ships reading and transmitting 4 symbologies • Bar graph ships in “Scanning Efficiency” mode • Mounting achieved without manuals or computer feedback • Installer leaves bar graph in “Scanning Efficiency” mode for future monitoring • Bar graph modes can be enabled without affecting the normal operation of the scanner

Solutions with Vision

Page 24

1-12

MODEL 10 OPERATIONS AND MAINTENANCE MANUAL

READ CHARTS The following charts depict the scanning capabilities of the Model 10 in relation to the optical setup. There are two optical setups available for the Model 10. • A - General Purpose • B - High Density

GENERAL PURPOSE Laser Diode Nominal outgoing laser power Scans Per Second Pitch Skew Depth of Field + Scan Window Minimum allowable print contrast signal (PCS) Scan Angle

Narrow Element Width 10.0 mil (.25mm) 15.0 mil (.38mm) 20.0 mil (.50mm) 25.0 mil (.88mm)

650 nm / 7 mW 2.5 mW 300 +/- 10° +/- 20° (do not mount at 0° skew) based on ≥96% scanning efficiency 75%. Read chart obtained using Code 39 ANSI grade "A" bar codes. Laser printed, black on white. Results may vary depending on symbology and code quality 80°

Reading Range 2.5”-5” (63.5-127mm) 1”-7” (25.4-178mm) 1”-8” (25.4-203mm) 1”-8.25” (25.4-210mm)

Depth of Field 2.5” (63.5mm) 6” (152mm) 7” (178mm) 7.25” (184mm)

read chart in 1 2 3 4 5 6 7 8 9 mm 0.127 0.191 0.254 0.381 0.508 0.635+

Maximum Scan Window 5.0” (127mm) @ 2.8” (71mm) 8.0” (203mm) @ 4.6” (116mm) 8.0” (203mm) @ 4.6” (116mm) 8.0” (203mm) @ 4.6” (116mm)

General Purpose Read Chart

Accu-Sort Systems

“x” element mil 5 7.5 10 15 20 25+ mm 25.4 50.8 76.2 101.6 127.0 152.4 177.8 203.2 228.6

Page 25

INTRODUCTION

1-13

HIGH DENSITY Laser Diode Nominal outgoing laser power Scans Per Second Pitch Skew Depth of Field + Scan Window Minimum allowable print contrast signal (PCS) Scan Angle

Narrow Element Width 5.0 mil (.13mm) 7.5 mil (.19mm) 10.0 mil (.25mm) 15.0 mil (.38mm)

650 nm / 7 mW 2.0 mW 200 +/- 10° +/- 20° (do not mount at 0° skew) based on ≥96% scanning efficiency 75%. Read chart obtained using Code 39 ANSI grade "A" bar codes. Laser printed, black on white. Results may vary depending on symbology and code quality 80°

Reading Range 1.5”-3” (38.1-76.2mm) 1”-3.5” (25.4-88.9mm) 1”-4” (25.4-101.6mm) 1”-4.5” (25.4-114.3mm)

Depth of Field 1.5” (38.1mm) 2.5” (63.5mm) 3” (76.2mm) 3.5” (88.9mm)

“x” element read chart mil 5 7.5 10 15 20 25+ in 1 2 3 4 5 6 7 8 9 mm 0.127 0.191 0.254 0.381 0.508 0.635+ mm 25.4 50.8 76.2 101.6 127.0 152.4 177.8 203.2 228.6

Maximum Scan Window 3.9” (99mm) @ 2.1” (53mm) 4.25” (107mm) @ 2.37” (60mm) 4.8” (122mm) @ 2.6” (66mm) 5.6” (142mm) @ 3.3” (84mm)

High Density Read Chart

Solutions with Vision

Page 26

1-14

Accu-Sort Systems

MODEL 10 OPERATIONS AND MAINTENANCE MANUAL

Page 27

Chapter Two Configuring the System

2Heading 2

Chapter Two

Contents

WIRING AND TERMINATING CONNECTIONS ................................................. 2-3 OBJECT-SENSING SIGNAL DEVICE ......................................................... 2-4

Page 28

2-2

Accu-Sort Systems

MODEL 10 OPERATIONS AND MAINTENANCE MANUAL

Page 29

CONFIGURING THE SYSTEM

2-3

WIRING AND TERMINATING CONNECTIONS Do not turn on the system until all components are properly cabled and grounded with three-pronged conductor AC power cords. Do not use a two-prong adapter. Do not use an extension cord to defeat the ground. You must use shielded interface cables with this product. To maintain FCC compliance, the cable shield must make a 360° connection to the shielded mating connector.

You must connect all peripheral equipment before you begin operating the system. Below is a table of the different cable pin configurations for the Model 10: CABLE PIN CONFIGURATION 1000008760 1000008758 1000008759 15 Flying Leads, 15-pin high-density EM-50-connector Function stripped and tinned ‘D’ sub- connector DC+ WHT/RED 14 J1 - 6 DC+ VIO 15 J1 - 7 GND WHT/BRN 1 J2 - 1 GND BLU 11 J1 - 8 TRIG+ YEL 10 J1 - 3 TRIGWHT 13 J1 - 5 TXD GRN 2 J2 - 2 RXD BRN 3 J2 - 3 RTS RED 12 no connect CTS BLK 9 J1 - 2 SD+ WHT/YEL 6 J2 - 6 SDWHT/BLK 8 J2 - 8 OUT0 WHT/ORG 4 J2 - 4 OUT1 GRY 5 J2 - 5 OUTC ORG 1* J1 - 1* Shield Braid Shell Braid *Tied to ground at connector termination to maintain compatibility with the respective product

Cable Pin Configurations

Solutions with Vision

Page 30

2-4

MODEL 10 OPERATIONS AND MAINTENANCE MANUAL

OBJECT-SENSING SIGNAL DEVICE The Model 10 must be informed when an object on the conveyor is about to enter its reading zone. An object-sensing signal device is typically used to do this. The device is mounted on the conveyor upstream from the Model 10 in relation to conveyor travel. It informs the Model 10 when the leading edge and trailing edge of objects traveling on the conveyor have passed. The typical object-sensing option for use with the Model 10 is: • Retroreflective Pair: An emitter bounces a light beam off a reflector, and detects when the beam is broken. The object sensing signal device will be connected to the 9-pin female connector TRIGGER (J2) on the Small Scanner Interface, or the terminal block connector on the EM-50. You must use shielded interface cables with the Model 10. To maintain FCC compliance, the cable shield must make a 360° connection to the shielded mating connector.

For mounting instructions on your object-sensing signal device, refer to shipkit 1000020527. For setup instructions, refer to the Accu-Setup Suite: Small Scanner Module Software Manual.

Accu-Sort Systems