The text of a manual · part 2 of 11
Model 10 Bar Code Scanner Operations and Maintenance Manual, pages 11 to 20
Pages 11 to 20 of 102
The original document is the PDF (6.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort Model 10
Page 11
Table of Figures MODEL 10 SERIAL TAG ................................................................................................................................... III MODEL 10 LABELS AND LOCATIONS .................................................................................................................VI PARTS TABLE............................................................................................................................................... 1-6 TYPICAL MODEL 10 INSTALLATION (MATERIAL HANDLING).............................................................................. 1-8 TYPICAL MODEL 10 INSTALLATION (EMBEDDED) ............................................................................................ 1-8 BOTTOM LABEL OF MODEL 10 WITH MODEL CONFIGURATION ......................................................................... 1-9 MODEL 10 DIMENSIONS ............................................................................................................................. 1-10 GENERAL PURPOSE READ CHART............................................................................................................... 1-12 HIGH DENSITY READ CHART ....................................................................................................................... 1-13 CABLE PIN CONFIGURATIONS ....................................................................................................................... 2-3 POWER CONNECTION EXAMPLE .................................................................................................................... 3-3 MOUNTING SCREW SELECTION ..................................................................................................................... 3-4 MOUNTING CONTACT POINTS ....................................................................................................................... 3-5 MOUNTING COLUMN WITH MULTIPURPOSE MOUNTING BRACKET .................................................................... 3-6 MULTIPURPOSE MOUNTING BRACKET ........................................................................................................... 3-7 UNIVERSAL MOUNTING SHIPKIT .................................................................................................................... 3-8 UNIVERSAL MOUNTING SHIPKIT MOUNTING HOLES ........................................................................................ 3-8 UNIVERSAL MOUNTING SHIPKIT .................................................................................................................... 3-9 UNIVERSAL MOUNTING BRACKET .................................................................................................................. 3-9 BALL AND SOCKET MOUNT ......................................................................................................................... 3-10 BALL & SOCKET MOUNT TERMS ................................................................................................................. 3-11 MODEL 10 LED DESCRIPTIONS .................................................................................................................... 4-3 FIVE SEGMENT LED BAR GRAPH DISPLAY .................................................................................................... 4-3 MODE 1 SEGMENT VALUES .......................................................................................................................... 4-4 MODE 2 SEGMENT VALUES .......................................................................................................................... 4-5 ACCU-SORT DIAGNOSTIC CODE.................................................................................................................... 4-6 LABEL PRINTING VERIFICATION APPLICATION ................................................................................................ 7-3 BAR CODE VERIFICATION APPLICATION ......................................................................................................... 7-3 PC BOARD TRACKING APPLICATION.............................................................................................................. 7-4 PRODUCT COUNTING APPLICATION ............................................................................................................... 7-4 PRODUCT IDENTIFICATION APPLICATION ........................................................................................................ 7-5 AUTOMATED BLOOD ANALYZER APPLICATION ................................................................................................ 7-5 RS485 COMMUNICATIONS EXAMPLE ............................................................................................................A-3 MASTER/SLAVE TIMING DIAGRAM .................................................................................................................A-5 ASCII CHART ..............................................................................................................................................A-9
Page 12
MODEL 10 OPERATIONS AND MAINTENANCE MANUAL
Accu-Sort Systems
Page 13
Chapter One Introduction
1Heading 2
Chapter One
Contents
CHECKING THE PACKING SLIP ................................................................... 1-3 GENERAL DESCRIPTION OF SYSTEM OPERATION ....................................... 1-7 BLOCK DIAGRAM OF MODEL 10 SYSTEM ................................................... 1-9 PRODUCT SPECIFICATIONS...................................................................... 1-10 FEATURES .......................................................................................... 1-11 READ CHARTS ........................................................................................ 1-12 GENERAL PURPOSE ............................................................................ 1-12 HIGH DENSITY ..................................................................................... 1-13
Page 14
1-2
Accu-Sort Systems
MODEL 10 OPERATIONS AND MAINTENANCE MANUAL
Page 15
INTRODUCTION
1-3
CHECKING THE PACKING SLIP Enclosed in plastic on the outside of your box is a packing slip. The packing slip lists the parts of your order. As soon as you open the box, check the equipment against the packing slip to ensure you received everything you ordered. If any equipment is missing or has been damaged during shipment, contact Accu-Sort immediately at 1-800-BARCODE (refer to Customer Service). The Model 10 packaging was specifically designed to protect the unit during shipment. Do not throw it away. Save all the packaging materials in case you have to transport your unit to a different building.
Depending upon your needs, you may have one or more of the pieces of equipment shown in the following table:
Solutions with Vision
Page 16
1-4
MODEL 10 OPERATIONS AND MAINTENANCE MANUAL DRAWINGS ARE NOT TO SCALE
Model 10
Model 10 Options 1. Optical Setup 2. Customization 3. Mirror Wheel
Part Number Description 1000001001 Scanner with Internal Logic
1000022760 1000024871 1000022761 1000003008 1000003727 1000003728 1000004679 1000004680 1000008758 1000008759 1000008760
Straight (6-sided) Raster (6-sided) 1/2" @ 5.0" Raster (6-sided) !/4" @ 5.0" Logic Board 5 VDC Variable Custom Supply Voltage (10.0 - 30.0 VDC) 1 Meter, 20 Compatible 15pin 1 Meter, EM-50 Compatible 1 Meter, Flying Leads, 15 Conductors
1000025466 1000025467 1000025468 1000025469 1000025470 1000025471 1000025472 1000025473 1000025474 1000025475 1000025476 1000025477
General Purpose, 10 mil min, .5@5 Raster, EM (300 Scans/Second) 5VDC General Purpose, 10 mil min, .5@5 Raster, FF (300 Scans/Second) 5VDC General Purpose, 10 mil min, .5@5 Raster, FF (300 Scans/Second) 24VDC High Density, 5 mil min, .5@5 Raster, EM (200 Scans/Second) 5VDC High Density, 5 mil min, .5@5 Raster, FF (200 Scans/Second) 5VDC High Density, 5 mil min, .5@5 Raster, FF (200 Scans/Second) 24VDC General Purpose, 10 mil min, .25@5 Raster, EM (300 Scans/Second) 5VDC General Purpose, 10 mil min, .25@5 Raster, FF (300 Scans/Second) 5VDC General Purpose, 10 mil min, .25@5 Raster, FF (300 Scans/Second) 24VDC High Density, 5 mil min, .25@5 Raster, EM (200 Scans/Second) 5VDC High Density, 5 mil min, .25@5 Raster, FF (200 Scans/Second) 5VDC High Density, 5 mil min, .25@5 Raster, FF (200 Scans/Second) 24VDC
4. Supply Voltage
5. Cable Configuration
General Purpose 10 mil min. (300 scans/sec) High Density (200 scans/sec)
OTS Distributor Units
Model 10 Accessories Interface Boxes/Expansion Modules 1000017362 Small Scanner Interface without relays 1000017365 Small Scanner Interface with relays 1000017376 Small Scanner Interface with solid state relays
1000015791 Scanner Expansion Module
Power Supplies 1000022163 1000015618 1000017369 1000017371 1000017370 1000017372
Accu-Sort Systems
110V AC Power Supply (for Small Scanner Interface) 220V AC Power Supply (for Small Scanner Interface) 120V AC 5V DC Programming Kit 220V AC 5V DC Programming Kit 110V AC 12V DC Programming Kit (for Optional Input Voltage) 220V AC 12V DC Programming Kit (for Optional Input Voltage)
Page 17
INTRODUCTION
1-5 DRAWINGS ARE NOT TO SCALE Part Number Description
Photoeyes 1000020527 Standard 9 Pin D Connector Photoeye Kit
Mounting Equipment 1000003614 Bracket Mounting, Universal
1000003627 Universal Mounting Shipkit (includes 1000003614)
1000003656 Ball and Socket Mount Kit
1000018197 Mounting Structure Assembly
1000018208 Mounting Kit
Displays 1000016277 External Display 1000016281 External Display w/ 10 Ft. Cable
1000016280 110V External Power Supply for Display 1000016283 220V External Power Supply for Display
Solutions with Vision
Page 18
1-6
MODEL 10 OPERATIONS AND MAINTENANCE MANUAL DRAWINGS ARE NOT TO SCALE Part Number Description
Lamp Enclosures 1000017045 Single Green Lamp Enclosure 1000017046 Single Red Lamp Enclosure 1000017047 Dual Lamp Enclosure
Communication Interfaces 1000015450 15 pin port DeviceNet 1000015843 External Serial to Ethernet Converter Kit (Plugs into 15 pin connector on scanner) Model 10 Documentation 1000025606 Small Scanners Installation Software and User Documentation CD-ROM
Parts Table
Accu-Sort Systems
Page 19
INTRODUCTION
1-7
GENERAL DESCRIPTION OF SYSTEM OPERATION The Model 10 combines impressive optical performance with useful electrical features in a rugged IP-65 / NEMA 4 rated enclosure. Its compact size, zero clearance cable exit, and flexible software parameters ease integration into existing as well as new designs. Fault tolerant inputs and outputs provide protection against field miswiring. Solid state relay outputs interface directly with PLCs requiring either current sourcing or sinking. Versatile mounting features including M3 metric threaded holes allow mounting on two sides and require no additional brackets. Installation is simplified with visual diagnostics designed to verify scanning efficiency. The Model 10 features: • Lowest cost Accu-Sort solution • Widest scan angle for its size • Easy integration • Easy installation • 2 Optical setups • Material Handling and Embedded applications
The system contains: • NEMA 4 / IP-65 enclosure • Integrated pigtail cable • Bar graph LEDs • Individual LEDs • Diagnostic Pushbutton • 2M on board FLASH memory • Diagnostic bar code support • Windows Setup Program
Typical applications include: • Automatic Teller Machines • Library access control systems • Medical specimen tracking systems • Document handling machines • Label printer verification • Semiconductor wire bonding machines
Solutions with Vision
Page 20
1-8
MODEL 10 OPERATIONS AND MAINTENANCE MANUAL
Typical Model 10 Installation (Material Handling)
Typical Model 10 Installation (Embedded) The installation of the Model 10 as an embedded laser normally requires that the end product be certified to the regulations of the Center for Devices and Radiological Health (CDRH).
Accu-Sort Systems