The text of a manual · part 24 of 26
AXIOM / AXIOM-X Product Line Manual: Appendices, pages 205 to 213
Pages 205 to 213 of 230, from AXIOM / AXIOM-X Product Line Manual
The original document is the PDF (7.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort Axiom 400 and Accu-Sort Axiom-X
Page 205
AXIOM™ / AXIOM-X™ Product Line Manual
Appendices
D FAST Monitor Configuration FAST Monitor and AXIOM This version of AXCESS provides setup compatibility with Accu-Sort System’s FAST Monitor™. FAST Monitor is a browser-based application, running on a FAST Monitor Server, that gives facility managers and maintenance personnel the ability to monitor multiple Accu-Sort products within their facility or across multiple facilities from anywhere an internet connection is available. FAST Monitor provides real time and historical performance data in an easy to use browser interface as well as automatic status and error condition reporting of all Accu-Sort products and systems to which it is connected. Use the FAST Monitor Configuration screen in AXCESS to setup an AXIOM reader for FAST Monitor message format compatibility.
How to Configure an AXIOM for FAST Monitor compatibility: 1. Modify > Configuration Options a. Select Collect FAST Monitor Statistics (checkbox) b. Set Reader Name (See page 206.) 2. Modify > Network Settings a. Set the Controller/Client Configuration for each AXIOM for either Controller (or standalone) or Client (See page 207.) 3. Modify > FAST Monitor Configuration a. Set Tunnel Information Tunnel Name (Standalone or Controllers, ignored for Clients) Unit Position (for all readers) b. Set the Net Host Port 2 information (Standalone or Controller only) (See page 208.)
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Accu-Sort Systems, Inc.
205
Page 206
206
Appendices
AXIOM™ / AXIOM-X™ Product Line Manual
1. Modify > Configuration Options for using FAST Monitor To enable the FAST Monitor message format, go to the AXIOM Configuration and select the Collect FAST Monitor Statistics checkbox. Even though the Ethernet messaging portion for FAST Monitor setup is only applicable for an AXIOM controller or stand-alone unit, client units must still have this option selected in order to set unit position, which is only accessible from the FAST Monitor Configuration menu screen. The Reader Name (set in the AXIOM Configuration menu) is used in all FAST Monitor messaging. Enter a unique alphanumeric name of up to 15 characters in the Reader Name field for all AXIOMs in the tunnel (controller and all clients). FAST Monitor uses this name to identify the AXIOM in a tunnel. When the Collect FAST Monitor Statistics checkbox is selected, the FAST Monitor Configuration menu selection appears in the menu tree.
Accu-Sort Systems, Inc.
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Page 207
AXIOM™ / AXIOM-X™ Product Line Manual
Appendices
2. Modify > Network Settings for using FAST Monitor Go to Modify > Network Settings. Set up the AXIOM as a stand-alone unit, a controller, or a client.
Controller/Client Configuration Settings Number of Client Readers Group Number
Standalone
Controller
Client
=0 =0
>0 >0
=0 >0
Example:
Since the Collect FAST Monitor Statistics option was checked, the Net Host Port2 panel is masked out. Parameters for Net Host Port2 (used for FAST Monitor communications) are set on the FAST Monitor Configuration screen.
NOTE: Group number must be the same for all AXIOM units in the tunnel.
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Accu-Sort Systems, Inc.
207
Page 208
208
AXIOM™ / AXIOM-X™ Product Line Manual
Appendices
3.
Modify > Configuration Options for using FAST Monitor Enter the FAST Monitor Configuration menu selection.
For controller or standalone units, set the following parameters: Set a Tunnel Name of up to 15 alphanumeric characters. This name is used in all FAST Monitor messages (bracketed by <MsgSource> name </MsgSource>). Set Unit Position by clicking on the appropriate AXIOM unit in the tunnel picture and setting a number. The numeric display is for informational purposes only. Each unit in the tunnel must have a unique position, which is used in all FAST Monitor messaging. The following Net Host Port2 settings are programmable: ƒ ƒ ƒ
Port Number Reconnect Time Remote IP Address (of FAST Monitor server)
NOTE: AXCESS forces FAST Monitor to use Net Host Port2. If Ethernet host communications are required, you must use Net Host Port1. For client units, set the Unit Position as described above.
Accu-Sort Systems, Inc.
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Page 209
AXIOM™ / AXIOM-X™ Product Line Manual
Appendices
E Installation Drawings Mechanical Drawings ƒ
AXIOM Line Scanner Mechanical Specification (104664)
ƒ
AXIOM Installation Drawing (105534)
ƒ
Dual AXIOM X-Pattern Mounting Bracket (XMB) Installation (106227)
ƒ
AXIOM-X Omnidirectional Scanner Mechanical Specification (108828)
ƒ
AXIOM-X Installation Drawing (109259)
ƒ
Photoeye Mounting (for Accu-Sort Structures) (41222)
ƒ
Photoeye Mounting (24130)
ƒ
Height Tracking Photoeye Mounting Adapter (112697)
ƒ
Universal Mounting Plate – AXIOM and IP65 Power Supplies (112465)
Interconnect Drawings The interconnect drawings provided in this appendix are useful when wiring your AXIOM / AXIOM-X for the following applications:
A1-AXIOM-AXIOM-X_Appendices_R10.doc
ƒ
Controller/Client with Tachometer (107480)
ƒ
Controller/Client/Client with Tachometer (107481)
ƒ
Start/End Trigger Photoeyes (107482)
ƒ
Stack Light with Internal Relays (107483)
ƒ
Height Tracking Photoeyes – AXIOM-X only (109364)
Accu-Sort Systems, Inc.
209
Page 210
210
Appendices
AXIOM™ / AXIOM-X™ Product Line Manual
Notes:
Accu-Sort Systems, Inc.
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Page 211
4
3
NOTES: 1) SCANNER WEIGHT: 10LBS [.66KG] 1) DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS
2
1 REVISIONS CHANGES REV 1 RELEASED ECO 03-263 2 ECO 03-894
10.87 276.22
BY TJB TJB
DATE 03.26.03 09.16.03
D
D
6.23 158.14
C
C
5.190 131.83 3.86 98.02 SCAN LINE
3X MOUNTING HOLES SEE TABLE 1
6.102 155
B
B
3.543 90
TABLE 1 SCANNER ASSY NO 0-105261-001 0-105261-002
A
WIRING BASE ASSY NO 0-104477-001 0-104477-002
MOUNTING HOLE 10-32 UNF-2B .5[13]DP M5 X .8-6H .5[13]DP
A
PART NO. - UNLESS OTHERWISE SPECIFIED: DRAWN JJB DATE ALL DIMENSIONS ARE IN INCHES ALL ANGLES ARE 90 ° CHKD TJB DATE ALL C-SINKS ARE 82 ° ALL BEND RELIEFS TO SUIT ENGR TJB DATE TOLERANCES: LINEAR- .X±.100 ANGULAR- X±1.0° DEPT. .X±.10° .XX±.020 .XX±.01° .XXX±.005 .XXXX±.0005
THIS IS NOT A CONTROLLED COPY UNLESS STAMPED "CONTROLLED COPY" IN RED
4
3
2
ACCU-SORT SYSTEMS, inc. TELFORD, PA 18969 USA
03.24.03
THIS DOCUMENT IS PROVIDED FOR A SPECIFIC PURPOSE AND THE DISCLOSED 10.18.02 INFORMATION REMAINS OUR PROPERTY. IT MAY NOT BE DISCLOSED, COPIED, MECH ENG OR REPRODUCED, EXCEPT FOR THE N/A ESPECIFIC PURPOSE, WITHOUT ACCU-SORT'S PRIOR APPROVAL. THIS NOTICE MUST CUSTOMER N/A APPEAR ON ANY COPY OR REPRODUCTION FT.,IN ±1" FRACTIONS ±1/4 OF THIS DOCUMENT. C REMOVE SHARP EDGES AND BURRS CONTRACT # N/A 2001, ACCU-SORT SYSTEMS, INC. ^
REFERENCE DRAWINGS 105307 UNIVERSAL MOUNTING BRACKET 105534 INSTALLATION DRAWING
R
10.18.02
MECHANICAL SPECIFICATION DRAWING AXIOM400 SIZE
CAGE CODE
SCALE
NONE CAD SYS.
C
DWG. NO.
53830
1
SOLIDWORKS
104664 SHEET
1
OF
1
Page 212
8
H
7
6
5
4
3
2
REVISIONS
1
REV CHANGES 02 ECO 09-214
NOTES: 1) WHEN UNOBSTRUCTED AND WITHOUT POWER SUPPLY. WITH POWER SUPPLY DOWNWARD TRAVEL IS LIMITED TO 105°. OTHER OBSTRUCTIONS MAY LIMIT TRAVEL. 2) WHEN MOUNTED ON ACCU-SORT STRUCTURAL EXTRUSION. RE-POSITIONING OF MOUNTING BOLTS MAY BE REQUIRED.
BY
DATE 05/19/09
AS
H 10.87
YAW ±22.5°
8.75
G
G 4.99
7.77
F
F
YAW AXIS
E
E
PITCH 50° UP MAX 130° DOWN MAX SEE NOTE 1
ROLL 360° SEE NOTE 2
D
SCAN PLANE
D
3.86 5.83
8.71
C
C 1.97 2.94
3.49
PITCH AXIS
B .328 X 1.83 SLOT 5X
1.50
1.50
1.50
B
1.50 6.36
POWER SUPPLY NOT SHOWN FOR CLARITY
7.86 THIS IS NOT A CONTROLLED COPY UNLESS STAMPED “CONTROLLED COPY” IN RED THIS DOCUMENT IS PROVIDED FOR A SPECIFIC PURPOSE AND THE DISCLOSED INFORMATION REMAINS OUR PROPERTY. IT MAY NOT BE DISCLOSED, COPIED, OR REPRODUCED, EXCEPT FOR THE SPECIFIC PURPOSE, WITHOUT ACCU-SORT’S PRIOR APPROVAL. THIS NOTICE MUST APPEAR ON ANY COPY OR REPRODUCTION OF THIS DOCUMENT. C 2001 ACCU-SORT SYSTEMS, INC.
A REFERENCE DRAWINGS: 104664 MECHANICAL SPECIFICATION DRAWING - AXIOM400 SCANNER
8
7
6
5
4
3
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES [MILLIMETERS] ALL ANGLES ARE 90° ALL C-CINKS ARE 82° INCLUDED ANGLE ALL BEND RELIEFS TO SUIT TOLERANCES: [METRIC] INCH [X±2.500] .X±.1000 [.X±0.500] .XX±.0200 [.XX±0.130] .XXX±.0050 .XXXX±.0005 [.XXX±0.013]
ANGLULAR X±1.00° .X±0.10° .XX±0.01°
FRACTIONS ±1/4 FT.,IN ±1"
REMOVE SHARP EDGES AND BURRS
DRAWN
TJB
DATE
CHKD
TWJ
DATE
ENGR
TJB
DATE
DEPT.
MECH ENG
E-
N/A
CUSTOMER
N/A
CONTRACT #
N/A
R
05.06.03
ACCU-SORT SYSTEMS, inc. TELFORD, PA 18969 USA
05.12.03 05.06.03
INSTALLATION DRAWING - AXIOM 400
SIZE
D
SCALE
2
CAGE CODE
53830 NONE
DWG NO.
CAD SYS.
A
105534 SOLIDWORKS
1
SHEET
1
OF
3
Page 213
8
7
6
5
4
3
2
1
REVISION 02
H
H
SCANNER HEAD ASSEMBLY - AXIOM400 0104638001
G
G
WIRING BASE ASSEMBLY - AXIOM400 0104636001/002
F
F
E
E MOUNTING HARDWARE INCLUDED WITH UNIVERSAL MOUNTING BRACKET
UNIVERSAL MOUNTING BRACKET (UMB) 0105307001/002
D
D
BRACKET, POWER SUPPLY MOUNTING (INCLUDED WITH UMB 0105307002) MOUNTING HARDWARE INCLUDED WITH WIRING BASE ASSEMBLY
C
C
POWER SUPPLY 0105365001/002
B
B
PART NO. 0105534001
IP 65 POWER SUPPLY OPTION A
8
7
6
5
4
THIS IS NOT A CONTROLLED COPY UNLESS STAMPED “CONTROLLED COPY” IN RED THIS DOCUMENT IS PROVIDED FOR A SPECIFIC PURPOSE AND THE DISCLOSED INFORMATION REMAINS OUR PROPERTY. IT MAY NOT BE DISCLOSED, COPIED, OR REPRODUCED, EXCEPT FOR THE SPECIFIC PURPOSE, WITHOUT ACCU-SORT’S PRIOR APPROVAL. THIS NOTICE MUST APPEAR ON ANY COPY OR REPRODUCTION OF THIS DOCUMENT. C 2004 ACCU-SORT SYSTEMS, INC.
3
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES [MILLIMETERS] ALL ANGLES ARE 90° ALL C-CINKS ARE 82° INCLUDED ANGLE ALL BEND RELIEFS TO SUIT TOLERANCES: [METRIC] INCH [X±2.500] .X±.1000 [.X±0.500] .XX±.0200 [.XX±0.130] .XXX±.0050 .XXXX±.0005 [.XXX±0.013] FRACTIONS ±1/4 FT.,IN ±1"
REMOVE SHARP EDGES AND BURRS
ANGULAR X±1.00° .X±0.10° .XX±0.01°
DRAWN CHKD
XXX XXX
DATE
XX.XX.XX
DATE
XX.XX.XX
DATE
XX.XX.XX
ENGR
XXX
DEPT.
MECH ENG
E-
N/A
CUSTOMER
N/A
CONTRACT #
N/A
R
ACCU-SORT SYSTEMS, inc. TELFORD, PA 18969 USA
INSTALLATION DRAWING - AXIOM 400 SIZE
D
SCALE
2
CAGE CODE
53830 NONE
DWG NO.
CAD SYS.
105534 SOLIDWORKS
1
SHEET
2
OF
3
A