On-Demand Tag Tag Name AXIOMTag.Data[0]
Value Bar Code Sequence Number
AXIOMTag.Data[1] AXIOMTag.Data[2]
Bar Code Status Bar Code Size (words)
AXIOMTag.Data[3-66]
Bar Code Data
Description This field is updated every time the bar code data is updated. However, the bar code data will only be updated when the “Last Bar Code Sequence Number” (see Output Data) is set equal to this value. Not currently used. Number of words which contain the bar code data
Remote Setup and Diagnostics Monitoring an AXIOM with AXCESS When multiple AXIOMs are placed on the same network, each one may be accessed over the network using the AXCESS software. This allows for remote monitoring and setup of the AXIOMs. Additionally, the AXCESS software can be run multiple times on a single PC, so multiple AXIOMs can be monitored simultaneously. The AXIOM only supports one diagnostic network connection at a time, so if you leave AXCESS connected to an AXIOM on one PC, you will not be able to connect from another. If a diagnostic network connection to an AXIOM is terminated “ungracefully” (PC crash, network cable, disconnect, etc..) the AXIOM does poll the status of the connection by periodically sending a single STX character and will time-out the connection.
Web Status Interface The AXIOM supports a simple web interface that provides an overview of the AXIOM health and status.
FTP Interface The AXIOM supports a very simple FTP interface that can be used to (1) update/extract the firmware image, (2) update/extract the parameter settings and (3) extract the current AXIOM message log. The username for FTP access is always “axiom” and the password is specified within AXCESS. When updating the firmware within an AXIOM using FTP, the new firmware file (named *.img) is transfer to the AXIOM using the PUT command. The file transfer takes approximately 15 or 20 seconds after which all of the LED’s on the AXIOM bargraph will be illuminated. These will remain illuminated for 10 or 15 seconds while the contents of the file are verified. Next a “chaser light” sequence will start on the bargraph LED’s while the contents of the AXIOM flash memory are updated. Once completed, the AXIOM will reboot. Extracting the AXIOM firmware is just done using an FTP GET command.
Accu-Sort Systems, Inc.
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Page 197
AXIOM™ / AXIOM-X™ Product Line Manual
Appendices
The parameter settings can also be extracted and sent using FTP. These parameters are in the same format as an AXIOM AXCESS .pam file. Additionally, this file can be retrieved from the AXIOM using the GET command and transferred back to the AXIOM with a PUT command. The files transferred back to the AXIOM can be a subset of the original file in that some parameters can be removed from the file. If a parameter is not contained in a file, that parameter will be untouched when a new file is transferred to the AXIOM. This allows the creation of files that just contain specific parameters (match code values for example) that can be transferred to a number of AXIOMs for quick reconfiguration.
Network Administrator Information All setup and diagnostic communications by the AXCESS application are sent using TCP/IP socket connections to port 2001 on the AXIOM. This parameter can be changed (it is an advanced network setting within AXCESS), but no provision is provided for changing this on AXCESS. The capability to change this port number was provided primarily in case some sort of proxy access is required.
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Accu-Sort Systems, Inc.
197
Page 198
198
AXIOM™ / AXIOM-X™ Product Line Manual
Appendices
EtherNet/IP Object Models Glossary This is a description of the different data types that are used in the documentation of the object model. These are standard definitions of the Open DeviceNet Vendor Association (ODVA). For additional information, visit their web site: http://www.odva.org/.
Summary of Objects The following standard objects are supported. More details than provided in this appendix can be found in the EtherNet/IP™ Specification available from the Open DeviceNet Vendors Association (ODVA). ƒ ƒ ƒ ƒ ƒ ƒ
Identity Object (01HEX ) Message Router Object (02HEX) Assembly Object (04HEX) Connection Manager Object (06 HEX) TCP Object (F5HEX) Ethernet Link Object (F6 HEX)
The following Vendor Specific Objects have been defined to support the AXIOM Bar Code Reader. ƒ ƒ ƒ
Bar code Data Object (70 HEX) Discrete Input Data Object (71 HEX) Discrete Output Data Object (72 HEX)
Definitions The following table has a description of all of the data types used. USINT UINT UDINT STRING BYTE WORD DWORD
Accu-Sort Systems, Inc.
Unsigned Short Integer (8-bit) Unsigned Integer (16-bit) Unsigned Double Integer (32-bit) Character String (1 byte per character) Bit String (8-bits) Bit String (16-bits) Bit String (32-bits)
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Page 199
AXIOM™ / AXIOM-X™ Product Line Manual
Appendices
Standard Objects Identity Object (01HEX - 1 Instance) Class Attributes Attribute ID Name 1 Revision Instance Attributes Attribute ID Name 1 2 3 4 5 6 7
Data Type UINT
Vendor Number Device Type 0x00 – Generic Product Code Number Product Major Revision Product Minor Revision Status Word (see below for definition) Product Serial Number Product Name Structure of: Product Name Size Product Name String
Data Value 1
Access Rule Get
Data Type
Data Value
Access Rule Get Get
UINT UINT
25DEC 00HEX
UINT USINT USINT WORD
01 03 01 See Below
Get Get
UDINT
Unique 32 Bit Value
Get
Get
Get UINT USINT[0-32]
15 “Bar Code Reader”
Status Word Bit Bit = 0 Bit = 1 0 No I/O Connection I/O Connection Allocated 1 – 15 Unused Unused Common Services Service Code Implemented for Service Name Class Level Instance Level 0EHEX Yes Yes Get_Attribute_Single 05HEX No Yes Reset Reset Service Code Service Code Class Instance Attribute Description 05HEX 1 1 0 Force software reset 05HEX 1 1 1 Reload factory settings and reset
Message Router Object (02HEX) This object has no supported attributes.
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Accu-Sort Systems, Inc.
199
Page 200
200
AXIOM™ / AXIOM-X™ Product Line Manual
Appendices
Assembly Object (04HEX – 4 Instances) Class Attributes Attribute ID
Name
1 Revision 2 Max Instance Instance 0x64 Attributes (Input Instance 1) Attribute ID Name 3
Data Type
Data Value
UINT UINT
1 81
Data Type
Input Data Structure of: Discrete Input Word (see below) Bar code Sequence Number Bar code Status (reserved) Bar code Size Word Bar code Data [UINT]
UINT UINT UINT UINT UINT [ ] varies (up to 64) Discrete Input Word
Bit 0 AXIOM Programmable Output #1 1 AXIOM Programmable Output #2 2 AXIOM Programmable Output #3 3 AXIOM Programmable Output #4 4 AXIOM Programmable Output #5 5 AXIOM Programmable Output #6 6 AXIOM Programmable Output #7 7 AXIOM Programmable Output #8 8-15 Unused Instance 0x70 Attributes (Output Instance 1) Attribute ID Name 3
Data Type
Default Data Value
Access Rule Get Get Access Rule Get
0 0 0 0 0
Default Data Value
Access Rule Get / Set
Output Data Structure of: Discrete Output Word (see below) UINT 0 Last Bar code Seq. Num Received UINT 0 Discrete Output Word Bit Bit = 0 Bit = 1 0* Trigger Off Trigger On 1–7 Unused Unused 8* AXIOM Relay #1 Off AXIOM Relay #1 On 9* AXIOM Relay #2 Off AXIOM Relay #2 On 10* AXIOM Relay #3 Off AXIOM Relay #3 On 11* AXIOM Relay #4 Off AXIOM Relay #4 On 12-15 Unused Unused * If enabled on AXIOM Instance 0x80 Attributes (Configuration Instance) Most I/O clients include a Configuration path when opening an I/O connection to a server. There is no Configuration data needed. Instance 0x81 Attributes (Heartbeat Instance – Input Only) This instance allows clients to monitor input data without providing output data. Common Services Service Code Implemented for Service Name Class Level Instance Level 0EHEX Yes Yes Get_Attribute_Single 10HEX No Yes Set_Attribute_Single
Accu-Sort Systems, Inc.
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Page 201
AXIOM™ / AXIOM-X™ Product Line Manual
Appendices
Connection Manager Object (06 HEX) This object has no attributes.
TCP Object (F5HEX - 1 Instance) Class Attributes Attribute ID 1 Revision Instance Attributes Attribute ID 1 2 3 4
Name
Data Type UINT
Name
Status Configuration Capability Configuration Control Physical Link Object Structure of: Path Size Path
Data Type DWORD DWORD DWORD UINT Array Of WORD
Interface Configuration Structure of: IP Address UDINT Network Mask UDINT Gateway Address UDINT Name Server UDINT Name Server 2 UDINT Domain Name Size UINT Domain Name STRING 6 Host Name Structure of: Host Name Size UINT Host Name STRING Common Services Service Code Implemented for Class Level Instance Level 0EHEX Yes Yes
Data Value 1 Default Data Value 1 0 0
Access Rule Get Access Rule Get Get Get Get
2 0x20F6 0x2401
5
Get 0 0 0 0 0 0 0 Get 0 0 Service Name Get_Attribute_Single
Ethernet Link Object (F6 HEX - 1 Instance) Class Attributes Attribute ID 1 Revision Instance Attributes Attribute ID
Name
Data Type UINT
Name
Data Type
Data Value 1
Access Rule Get
Default Data Value 100 3 0
Access Rule Get Get Get
1 Interface Speed UDINT 2 Interface Flags DWORD 3 Physical Address USINT Array[6] Common Services Service Code Implemented for Service Name Class Level Instance Level 0EHEX Yes Yes Get_Attribute_Single
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Accu-Sort Systems, Inc.
201
Page 202
202
AXIOM™ / AXIOM-X™ Product Line Manual
Appendices
Vendor Specific Objects Bar Code Data Object (70 HEX - 1 Instance) Class Attributes Attribute ID Name
Data Type
1 Revision Instance Attributes Attribute ID Name 1 2 3 4
UINT
Default Data Value 1
Access Rule Get
Default Data Value 0 0 0 0
Access Rule Get Get Get Get
0
Get / Set
Data Type
Bar Code Sequence Number Bar Code Status (reserved) Bar Code Data Size Bar Code Data
UINT UINT UINT UINT[ ] varies (up to 64) UINT
5 Last Bar Code Seq. Num Received Common Services Service Code Implemented for Class Level Instance Level 0EHEX Yes Yes 10HEX No Yes
Service Name Get Attribute Single Set Attribute Single
Discrete Input Data Object (71 HEX - 1 Instance) Class Attributes Attribute ID
Name
1 Revision Instance Attributes Attribute ID Name 3
Discrete Input Word
Data Type UINT
Bit 0 AXIOM Programmable Output #1 1 AXIOM Programmable Output #2 2 AXIOM Programmable Output #3 3 AXIOM Programmable Output #4 4 AXIOM Programmable Output #5 5 AXIOM Programmable Output #6 6 AXIOM Programmable Output #7 7 AXIOM Programmable Output #8 8-15 Unused Common Services Service Code Implemented for Class Level Instance Level 0EHEX Yes Yes
Accu-Sort Systems, Inc.
Access Rule Get
Default Data Value
Access Rule Get
1
Data Type UINT Discrete Input Word
Default Data Value
0
Service Name Get Attribute Single
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Page 203
AXIOM™ / AXIOM-X™ Product Line Manual
Appendices
Discrete Output Data Object (72 HEX – 1 Instance) Class Attributes Attribute ID Name 1 Revision Instance Attributes Attribute ID Name 3
Discrete Output Data
Data Type UINT
Access Rule Get
Default Data Value
Access Rule Get / Set
1
Data Type UINT 0 Discrete Output Word Bit = 1 Trigger On Unused AXIOM Relay #1 On AXIOM Relay #2 On AXIOM Relay #3 On AXIOM Relay #4 On Unused
Bit Bit = 0 0* Trigger Off 1–7 Unused 8* AXIOM Relay #1 Off 9* AXIOM Relay #2 Off 10* AXIOM Relay #3 Off 11* AXIOM Relay #4 Off 12-15 Unused * If enabled on AXIOM Common Services Service Code Implemented for Class Level Instance Level 0EHEX Yes Yes 10HEX No Yes
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Data Value
Service Name Get_Attribute_Single Set_Attribute_Single
Accu-Sort Systems, Inc.
203
Page 204
204
Appendices
AXIOM™ / AXIOM-X™ Product Line Manual
Notes:
Accu-Sort Systems, Inc.