Page 71
To add a bar code manually: 1. To add a bar code, go to the Modify Settings > Bar Code screen. 2. Be sure you know the parameters for the symbology you are adding to your active list. 3. Select the symbology from the Code Type drop-down list. 4. Assign a unique Code Label, if necessary. 5. Define the minimum and maximum code length. 6. Define the minimum and maximum quantity. 7. Select the Modulo Check. 8. Enter a Filter, if required. 9. Click Add. The code added will appear in the Selected Symbologies list highlighted in yellow. 10. Click Update. 0. To edit a bar code: 1. To edit a bar code, go to the Modify > Bar Code screen. 2. Select an option button to highlight any Symbology listed under Selected Symbologies that you want to edit. 3. To change any of the settings (e.g. Code Label, Min/Max Length, Min/Max Quantity, Modulo Check, Extension), click in the field and make the required changes. 4. Click Update and then click the save icon (
).
To move a bar code: 5. To move a bar code, go to the Modify > Bar Code screen. 6. Select an option button to highlight any Symbology listed under Selected Symbologies that you want to move. 7. Click Move Up to move the selected bar code toward the top (beginning) of the list. 8. Click Move Down to move the selected bar code further back (toward the end) of the list. 9. Any changes are highlighted in the list. 10. Click Update and then click the save icon (
).0.
NOTE: Bar code data is transmitted in the order that they appear in the Selected Symbologies list.
To remove a bar code: 1. To remove a bar code, go to the Modify > Bar Code screen. 2. Select an option button to highlight any Symbology listed under Selected Symbologies that you want to remove. 3. Click Remove to delete the selected bar code from the list. 4. Click Update. 0.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 72
To create a bar code group: 1. Go to the Bar Code Groups tab. (This tab becomes available when two or more codes are available under Selected Symbologies.) 2. Create Group 1 by clicking the checkbox for the codes to be included in the group. 3. Create any additional groups required. 4. Click Update. 0. See also: Modify Settings > Bar Codes in Appendix C.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 73
Modify Settings > Modulo Checks Use the Modulo Checks screen to setup the user defined modulo checks for any bar code symbologies that you have specified need them. If you selected a User Defined Modulo Check while in the Modify Settings > Bar Codes setup screen, you will need to define it on the Modulo Checks screen. To set a user defined modulo check for a bar code: If a bar code requires a User Defined Modulo Check as defined on the Bar Codes page, go to the Modify Settings > Modulo Checks page. 1. Find the correct modulo check row (i.e., User Defined 1 through 5) for the code. 2. Set the Factor. 3. Set a Divisor. 4. Select Remain, if required. 5. Select Right, if required. 6. Select Wrap, if required. 7. Repeat as necessary for all codes with a user defined modulo check. 8. Click Update. 0. See also: Modify Settings > Modulo Checks in Appendix C.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 74
Modify Settings > Stripping/Padding For each symbology type (defined in Modify Settings > Bar Codes), stripping and/or padding of the bar code data can be specified. This stripping and padding is applied to the bar code before any message formatting. NOTE: Character stripping is applied before character padding.
To set the character stripping for a bar code: 1. Select the bar code from the Available Bar Codes drop-down list. 2. Click on the required character stripping option. 3. Proceed to character padding if required. 4. Click Update when finished. To set the character padding for a bar code: 5. Select the bar code from the Available Bar Codes drop-down list. 6. Click on the required character padding option. 7. Make the necessary entry based on the padding option selected. 8. Click Update. 0. See also: Modify Settings > Stripping/Padding in Appendix C.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 75
Modify Settings > Match Codes Use Modify Settings > Match Codes to define a specific code pattern within a symbology type that is to be considered a "match condition". In addition to identifying and reading a symbology you defined (using Modify Settings > Bar Codes), this feature enables you to configure a reader to match specific select characters within a bar code. All bar codes are compared to the complete list of Match Codes. If a bar code matches ANY of the codes defined in Match Code settings, it is considered a MATCH. When a match code is read, you can setup your reader to: • fire a relay output (Example: Activate a diverter)
• send a user-defined message (Example: Acknowledge match code found)
The following wildcards are available: •
"*" represents a string with arbitrary length
•
If you enter 9* and the AL5010 reads bar code data 91234567890, then the AL5010 will transmit a valid read to the host because the leading 9 matches the pre-defined match character. The rest of the characters in the bar code are not effected because the asterisk wildcard instructs the AL5010 that the 9 is the only character that need to be matched.
•
If the AL5010 reads bar code data 01234567890 then the AL5010 will transmit a no read because the leading 0 in the bar code did not match the pre-define 9.
•
"?" represents a single character
•
With this condition, the AL5010 will ignore the character located in the designated location in the data string and only match the identified data.
See also: Modify Settings > Match Codes in Appendix C. NOTE: If ANY match code pattern is set to “*” ALL codes will match it.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 76
Modify Settings > Serial Communications Use the Serial Communications menu tree selections to set the serial port connection parameters including: •
Baud Rate
•
Data Bits
•
Stop Bits
•
Parity
•
Flow Control
•
Message Format
Individual settings can be made for Serial Port 1 and Serial Port 2. If the User Defined Message format is selected, an addition tab screen is supplied for creating unique message definitions. Serial Port 1 and 2 Use Modify Settings > Serial Communications > Serial Port 1 (or 2) to define the format of message the reader sends to your host computer (or other device) connected to Serial Port 1 (or 2). To set or modify the communications parameters for Serial Port #1: 1. Go to the Serial Communications Port#1 screen. 2. Click a Baud Rate option group button. 3. Click a Data Bits option group button. 4. Click a Stop Bits option group button. 5. Click a Parity option group button. 6. Click a Flow Control option group button. 7. Select a Message Format from the drop-down list. 8. Click Update. 0. Message Definitions When any option, other then the Standard Message selection, under the Message Format item is selected a Message Definition tab is made available. Creating User-defined Messages NOTE: Use the same procedure to create user-defined messages for both the serial (Modify > Serial Communications Port #1 or Port #2) and network communications (Modify > Network Settings).
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 77
To create user-defined messages: Under Message Format, select User Defined Message. A Message Definitions tab becomes available. For the serial port, select Message Definitions – Port #1(or 2) (example shown below). For network communications, select Message Definitions – Net#1(or 2). To define message framing: Header - Character string specified for the header. Sent at beginning of every message. Trailer - Character string specified for the trailer. Use to terminate every message. Seq # - When enabled, a sequence number consisting of the specified number of digits is inserted just after the header. Check Digit - When enabled, a two-character hexadecimal check character is inserted just prior to the trailer. Include Multi-Bar code in single message (checkbox) - Affects how the reader handles multiple bar code transmissions. If enabled, the bar codes are sent in one message (between one header and trailer) and each bar code is separated by the specified “separator.” If disabled, all bar codes are always sent as a complete message (with a header and trailer). Bar Code Separator - String used to separate multiple bar codes (see above. Power Up/Connect Message - String that is always sent on reader initialization. Note that for a Network connection, this string is always sent when the socket connection is made. To define Serial Port 1 message content: The message drop-down lists define the message options for each bar code. The message content can be defined for transmissions from the reader’s serial port #1 as well as any network connection (via Net#1). These messages are based on various conditions. For each condition, there are options for what message can be sent. These options include: Send Bar Code - Bar code (with padding and/or stripping) is sent. Repeat Character - Send a message consisting of the specified character repeated for the minimum number of characters for the bar code (example is “???????” no-read message). User Specified Message - Send a message defined string for this condition. Category 1: Read, No Read, or Multiple Bar Code These three conditions are mutually exclusive, so only one of these three messages can be sent for any bar code. Read - If disabled, nothing is sent for a valid read; otherwise either the bar code or a user specified message is sent. No Read - If disabled, nothing is sent for a no-read; otherwise either the specified “repeated character” or the user specified message is sent.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 78
Multiple Bar Code - If disabled, a multiple bar code condition will be reported as a “Read” of the first bar code reported. Otherwise, the specified “repeated character” or the user-specified message is sent. Category 2: Match, No Match, No Match Read These conditions are IN ADDITION to the conditions specified in Category 1. If a condition in both categories is met, these messages will be appended. If you desire to only generate a message based on Category 2 conditions, all messages in Category 1 should be disabled. Match - If the bar code matches any of the match codes, this message is sent. Options include sending the bar code or a user specified message. No Match - If the bar code does not match any of the match codes (or was a no-read), this message is sent. Options include sending a “repeated character” or a user specified message. No Match Read - If a valid bar code was read, but it does not match any of the match code, this message is sent. Options include sending the bar code or a user specified message. Category 3: Append QQ, Heart Beat Message, and Heart Beat Timeout Append QQ (code quality) to message (checkbox) - When selected a two digit “code quality” indication (number from 00 to 99) is appended to the bar code message. The code quality value is separated from the message with the specified separator. Heart Beat Message - When enabled, if no other message is sent for the time period specified in Heart Beat Time Out, the specified heart beat message string is sent. A time-out of zero disables the heart beat message. Heart Beat Time Out (0-30,000 ms) - 0 = Disable Heart Beat Message, 130,000 = Delay before sending Heart Beat Message Append Distance to Message - allows the AL5010’s measured approximate distance from the scanner to the bar code read to be in the transmitted message. See also: Modify Settings > Serial Communications in Appendix C.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 79
Modify Settings > Network Use Modify Settings > Network to specify network settings (including the IP address) for the reader. Currently, the reader can only be configured to use a Static IP address. Net Host Port1 and Net Host Port2 define two network connections for sending bar code messages. The Connection Type and Message Format for each port can be set independently. Message formatting is the same as for the serial port. •
IP Address - An IP address specifies a unique host ID for the reader on a particular TCP/IP network. Consult your network administrator for a valid IP address for the reader.
•
Net Mask - A netmask modifies a standard IP address into subnets. A default net mask should be valid in most cases (255.255.255.0). Consult your network administrator for the net mask value.
•
Gateway IP Address - A gateway allows the reader to reach other systems not on the local network and remote systems to reach the reader. If the reader requires external connectivity, consult your network administrator for a valid gateway address.
Net Host Port 1 or 2 Connection Type The following connection types are available for each network port: •
TCP/IP Server: As a TCP/IP server, a Port # must be specified. In this case it is the TCP/IP client’s responsibility to initiate a reader connection.
•
TCP/IP Client: As a TCP/IP client, aside from the Port #, the Remote IP Address of the TCP/IP server which is to receive the barcode messages must be specified. The Reconnect Time specifies the interval (in seconds) at which the reader attempts to establish a connection.
•
UDP Messaging: In some instances, it may be desirable to use a connectionless UDP message to send bar code data. In this case, only the Port # and Remote IP Address of the receiver need to be specified.
•
EtherNet/IP (Net Host Port 1 only): This enables use of the EtherNet/IP protocol on the reader.
•
Message Format - There are four message format options: Custom Message, Standard Message, User Defined Message, and MUX (ADP) Message.
Controller/Client Configuration Number of Client Readers - The number of client readers in a multi-reader network must be defined on the reader acting as the Controller. Drop-down list selectable for up to 14 readers functioning as “Clients”. Client readers must be set at zero (0). Group Number - All readers in a Controller/Client group (both the Controller and ALL Clients) must be set to the same controller group number. The default of zero (0) disables a reader from listening for messages to become a client.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 80
Ethernet Link Drop-down list with 5 selections: AutoDetect, 100 Mbps/Full Duplex, 100 Mbps/Half Duplex, 10 Mbps/Full Duplex, 10 Mbps/Half Duplex •
Controller Multicast IP Address: This is the IP address used by this controller to communicate to its Group (Identified by the Group No.) to broadcast such messages as tach and trigger.
NOTE: This IP address should not be changed. •
Telnet Port: The port number used to Telnet into the AL5010.
Message Definitions Whenever you specify a user-defined message format for either serial port #1 or network settings, Message Definitions become available Creating User-defined Messages
NOTE: Use the same procedure to create user-defined messages for both the serial (Modify > Serial Communications Port #1) and network communications (Modify > Network Settings).
To create user-defined messages: Under Message Format, select User Defined Message. A Message Definitions tab becomes available. For the serial port, select Message Definitions – Port #1 (example shown below). For network communications, select Message Definitions – Net#1. To define message framing: Header - Character string specified for the header. Sent at beginning of every message. Trailer - Character string specified for the trailer. Use to terminate every message. Seq # - When enabled, a sequence number consisting of the specified number of digits is inserted just after the header. Check Digit - When enabled, a two-character hexadecimal check character is inserted just prior to the trailer. Include Multi-Bar code in single message (checkbox) - Affects how the reader handles multiple bar code transmissions. If enabled, the bar codes are sent in one message (between one header and trailer) and each bar code is separated by the specified “separator.” If disabled, all bar codes are always sent as a complete message (with a header and trailer). Bar Code Separator - String used to separate multiple bar codes (see above. Power Up/Connect Message - String that is always sent on reader initialization. Note that for a Network connection, this string is always sent when the socket connection is made.