Page 61

DeviceNet

Profibus

Connecting the AL5010 Once all wiring is completed and checked for accuracy, connect the AL5010 Reader’s cable connections to the Interface Module. (See Wiring the Interface Modules in this chapter.) You can install the scan head with or without the power disconnected from the interface module. (See Installing the Scan Head in Chapter 3.)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 62

Wiring to the AL5010 without an Interface Module

AL5010 Pin-Out Table See also: Drawing 113493 in Appendix F.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 63

Check Installation After completing the installation of your AL5010: Confirm that the reader has been properly installed mechanically and electrically. Use the Installation Sequence at the beginning of this chapter and your application specifications to check your installation. Configure the reader’s parameters to meet the needs of your application. (See Chapter 5 and online help for details.) See Chapter 5 and 6 for details regarding first-time startup and an operations checklist.

Check installations using Basic Interface Module: 1. Apply power to the interface module. 2. Check the following: Power ‘on’ (POWER LED)

Trigger photoeye operation (TRIGGER LED)

3. Finger-tighten all water-tights. 4. Install cover. 5. Tighten four Phillips screws. Do not over tighten.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 64

56

AccuLazr™ AL5010 Product Line Manual

Electrical Installation

Check installations using Enhanced Interface Module: 1. Plug in the power supply. 2. Check the following: 3. Power ‘on’ (POWER LED)

Trigger photoeye operation (TRIGGER LED)

Tachometer operation (TACH LED)

Serial communications, receive data (RX1, RX2 LEDs)

Input Relay (if applicable, I/O 1 LED).

4. Finger-tighten all water-tights. 5. Install cover. 6. Tighten four Phillips screws. Do not over tighten.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 65

5 Setup Getting Started The AL5010 line of laser bar code readers is designed for ease-of-setup, allowing you to program a reader to fit your application seamlessly. AccuLazr™ User Interface for AL5010 is a browser-based application. It is the tool you will use to define operating parameters, determine bar code read quality, and construct output messages, including filtering, stripping and padding capabilities. AccuLazr User Interface enables you to easily configure, fine-tune, and monitor your AL5010’s operations. AccuLazr User Interface provides ease-of-use for any operator level. A beginner operator follows basic setup procedures for a standard configuration. More experienced operators may use the advanced setup features that allow access to more complex options.

Prerequisites Before setting up your AL5010 will need the following: •

Computer: Laptop or desktop

•

Browser: Internet Explorer 7 or Firefox 3.6 (or later)

•

Java: Version 6.0.210 (or later)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 66

Starting the AccuLazr User Interface To start the AccuLazr™ User Interface software in the Windows environment: 1. Open your web browser and enter the IP address for your AL5010 unit. If the correct IP address is entered, the AL5010 Login screen will appear (If you don’t know the IP address, see Discovering the IP Address in Chapter 8.) The default IP address is: 192.168.3.100 2. Enter the User ID and Password for your system in the fields provided. 3. Click Log On. The Home screen appears. 0.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 67

AccuLazr User Interface Basics AccuLazr™ User Interface Menu Tree The functions that you can select are displayed in a navigation list on the left–hand side of the AccuLazr™ User Interface. The function list is organized much like the hierarchy of a file system, where you can expand items that begin with a plus sign (+) to further sub–levels until you find a function of interest. Sub–levels appear indented below the items from which they are expanded. Items that are expanded are preceded by a minus sign (–). You can expand no further when an item displays neither a plus or minus sign. The AccuLazr™ User Interface menu tree appears with no items expanded. Click the folders to display the active window for the setup function and/or expand the folders to view any additional setup features.

Getting Help AccuLazr™ User Interface provides complete online help. To display help for a current window: Choose Help Index from the Help drop-down menu or press the icon at the top of the screen. A help window appears, providing you with information and an index of topics associated with the current application window. Click on a topic of interest to display more detailed information. You can use the menus or buttons in the help window to navigate to other topics of interest, or from the File menu in the help window, you can choose Exit to quit from Help.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 68

Modify Settings Use the Modify Settings menu tree selections during initial setup to configure your AL5010 Laser Bar Code Reader. If necessary, you can later make modifications to the reader’s configuration using the same menu selections, including: •

Configuration

•

Bar Codes / Bar Code Groups

•

Modulo Checks

•

Stripping and Padding

•

Match Codes

•

Serial Communications

•

Network Communications

•

Message Definitions

•

Trigger

•

Relay

•

Tracking

•

FAST Monitor Setup

•

Advanced Settings

•

Raster

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 69

Modify Settings > Configuration Use Configuration to identify and configure an AL5010 bar code reader. This includes access to reader information as well as configuration options (scan rate, control panel and network access). To set the reader Configuration: 1. Click in the Reader Name entry field and enter a unique reader name up to 15-characters in length. Use of unique reader names is especially useful in multiple scanner applications. 2. Adjust the scan rate, if necessary. 3. Enable Trigger/Track Controlled Laser, if required by your application. 4. Set the Units of measure for either ENGLISH or METRIC. 5. Assign a unique Username and Password. 6. Click Update. 0. CAUTION: Changing the scan rate can adversely affect reader performance. Do not change the scan rate unless instructed to do so by Accu-Sort Technical Support.

See also: Modify Settings > Configuration in Appendix C.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 70

Modify Settings > Bar Codes Use Bar Codes to define the symbologies the AL5010 should read for your application. Modulo check verification within a bar code can also be specified. Create bar code groups, if needed. Bar Code Groups When more than one bar code type is in the Selected Symbologies list, the Bar Code Groups tab is available. This enables you to define the valid “groups” of bar codes that are to be transmitted together. For example, in the Modify Settings > Bar Codes, Bar Code Group tab shown here, the reader is configured to transmit EITHER: •

Group 1: a code 128 bar code, or

•

Group 2: both an Interleaved 2 of 5 code and a Code 39 code.

To add a bar code using Learn Bar Code: 1. Click Learn. The Bar Code Learn screen is displayed. 2. Hold the bar code (as illustrated in the user interface) within the reader’s depth of field. The reader will attempt to read the bar code for three minutes to 'learn' all codes in the scan line. After three minutes, the reader will stop the learn operation. If necessary, click Cancel Learn to stop Learn Bar Code. NOTE: When one code is in the scan line, it must be saved after Learn before another code can be “Learned.”

3. Once the reader has finished ‘learning’ it displays a list of all codes including the code data. 4. If no codes are found within three minutes, the Learn Bar Code function will end. 5. Use the checkboxes to select any of the codes learned to the Selected Symbologies list. 0. Click ‘Add’. The codes will be added to the Selected Symbologies list. NOTE: The reader can learn multiple bar codes appearing in the scan line at the same time. REMEMBER: These 'learned' codes that are added to Selected Symbologies will only be added to the reader's functional parameters after clicking Update. Use the Save to Reader function (found on the Save/Retrieve screen) to save the parameters for continuous use.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net