The text of a manual · part 9 of 24
AccuLazr AL5010 Product Line Manual, pages 81 to 90
Pages 81 to 90 of 236
The original document is the PDF (13 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort AL5010
Page 81
To define Serial Port 1 message content: The message drop-down lists define the message options for each bar code. The message content can be defined for transmissions from the reader’s serial port #1 as well as any network connection (via Net#1). These messages are based on various conditions. For each condition, there are options for what message can be sent. These options include: Send Bar Code - Bar code (with padding and/or stripping) is sent. Repeat Character - Send a message consisting of the specified character repeated for the minimum number of characters for the bar code (example is “???????” no-read message). User Specified Message - Send a message defined string for this condition. User Specified Message - Send a message defined string for this condition. Category 1: Read, No Read, or Multiple Bar Code These three conditions are mutually exclusive, so only one of these three messages can be sent for any bar code. Read - If disabled, nothing is sent for a valid read; otherwise either the bar code or a user specified message is sent. No Read - If disabled, nothing is sent for a no-read; otherwise either the specified “repeated character” or the user specified message is sent. Multiple Bar Code - If disabled, a multiple bar code condition will be reported as a “Read” of the first bar code reported. Otherwise, the specified “repeated character” or the user-specified message is sent. Category 2: Match, No Match, No Match Read These conditions are IN ADDITION to the conditions specified in Category 1. If a condition in both categories is met, these messages will be appended. If you desire to only generate a message based on Category 2 conditions, all messages in Category 1 should be disabled. Match - If the bar code matches any of the match codes, this message is sent. Options include sending the bar code or a user specified message. No Match - If the bar code does not match any of the match codes (or was a no-read), this message is sent. Options include sending a “repeated character” or a user specified message. No Match Read - If a valid bar code was read, but it does not match any of the match code, this message is sent. Options include sending the bar code or a user specified message. Category 3: Append QQ, Heart Beat Message, and Heart Beat Timeout Append QQ (code quality) to message (checkbox) - When selected a two digit “code quality” indication (number from 00 to 99) is appended to the bar code message. The code quality value is separated from the message with the specified separator. Heart Beat Message - When enabled, if no other message is sent for the time period specified in Heart Beat Time Out, the specified heart beat message string is sent. A time-out of zero disables the heart beat message. Heart Beat Time Out (0-30,000 ms) - 0 = Disable Heart Beat Message, 130,000 = Delay before sending Heart Beat Message See also: Modify Settings > Network in Appendix C.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 82
Modify Settings > Trigger The trigger helps the reader identify when products with bar codes are entering the scanning area. Use Modify Settings > Trigger Settings to set the various trigger parameters. Trigger Source There are three options for trigger source: •
Hardware Trigger
•
Software Trigger
•
Continuous Trigger
Since the trigger parameters vary based on trigger type selected, the trigger parameter options have been defined within the context of the specific trigger source. See also: Modify Settings > Trigger in Appendix C.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 83
Modify Settings > Relay Use to define functionality of any I/O relay module options utilized by your reader. For additional information and field descriptions, see Modify Settings > Relay in Appendix C. To configure an I/O relay: 1. Select the intended use of the relay (output or input). 2. Select the intended purpose for the relay. 3. Set for either Active High or Active Low. 4. For relay outputs, set an output signal duration. 5. After configuring the relays, click Update.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 84
Modify Settings > Tracking Use tracking in application that require: •
Tight package spacing
•
Transmit point is greater than the "smallest box + minimum box spacing" distance.
Use Modify Settings > Tracking to define all of the parameters associated with monitoring package travel on the conveyance system. The tracking parameters are only available if tracking is enabled, otherwise they are not shown in this window. To enable tracking: 1. Click in the Tracking Enabled checkbox. When tracking is enabled, a checkmark appears in the checkbox and the tracking parameter settings are visible in the Modify Settings > Tracking screen. 2. Adjust the tracking settings for Tachometer (Encoder), Reader Mounting, Transmit, and Tracking Configuration. 3. Click Update. 0. See also: Modify Settings > Tracking in Appendix C.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 85
Modify Settings > FAST Monitor™ FAST Monitor is a browser-based application, running on a FAST Monitor Server, that gives facility managers and maintenance personnel the ability to monitor multiple Accu-Sort products within their facility or across multiple facilities from anywhere an internet connection is available. FAST Monitor provides real time and historical performance data in an easy to use browser interface as well as automatic status and error condition reporting of all Accu-Sort products and systems to which it is connected. Use the FAST Monitor screen to configure an AL5010 reader for FAST Monitor message format compatibility. For additional information and field descriptions, see Modify Settings > FAST Monitor in Appendix C.
NOTE: For more information on FAST Monitor functionality, see the FAST Monitor Product CD, online help or contact us at 1-800-BAR-CODE.
To Configure an AL5010 reader for FAST Monitor messaging: 1. On the Modify Settings > Configuration screen, confirm a unique Reader Name is set. 2. On the Modify Settings > Network screen, confirm the reader is properly set as either the Controller or a Client. 3. Go to the Modify Settings > FAST Monitor screen. 4. Under Tunnel Information, assign a Tunnel Name. 5. Select the Reader Position from the drop-down menu. Reference the illustration for relative positions. 6. If the reader is a standalone unit or controller in a scanning tunnel, be sure to set the FAST Monitor Port information. The Port No. is always 9899. 0. IMPORTANT: Be sure to use a unique position that relates to the reader’s location in the scanning tunnel. Avoid assigning the same Reader Position to two different readers.
See also: Modify Settings > FAST Monitor in Appendix C.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 86
Modify Settings > Advanced The Advanced screen provides filters for enhancing the scanners ability to read a bar code. Adjusting these values may have a negative or positive effect on the reader’s ability to decode a bar code. The Data Filtering, DRX (Data Reconstruction) and Transmit QQ settings are considered advanced settings because they require comprehensive training to understand how they should be modified.
NOTE: Changing the Advanced settings can adversely affect reader performance. These settings are to be modified only under the guidance of Accu-Sort Technical Support.
Data Filtering The data filtering parameters specify the minimum and maximum pulse width (in counts) for the bar code data. This important data filter setting assures optimal reader performance. The Sampling Frequency default of 100 Mhz assures better decoder resolution for poorly printed bar codes. Scan Filtering (Skip Scan) – •
This option is used on applications that have slow conveyance and/or reading bar codes with a large bar height. Under these conditions the reader fills its memory with so much data that it does not have time to process all the data before the end of trigger, causing the reader to no-read. The Scan Filtering (Skip Scan) option limits the amount of data, allowing the reader to processing less data and give it a more of an opportunity to read the bar code.
Minimum Transitions – •
There have to be a certain number of bars and spaces detected on a scan line in order to consider the information valid. This option restricts data from being placed into memory.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 87
•
Should be at least as long as Start/Stop character. If short Start/Stop character, use the length of one data character plus the start/stop character (e.g.;I2 of 5)
•
In this subroutine, any group of elements less than the min trans setting is discarded or ignored.
Laser /Laser 2 DOF: Near Dist (in)/Far Dist (in) •
These options filter out any transitions beyond the entered values. Any transition (including bar codes) seen beyond these values are not placed into memory to be processed by the reader. This also includes valid bar codes.
•
As an example the above view shows the closest a bar code can be processed is six inches for Laser 1 and 27 inches for laser 2. Any bar code found closer then these values will be filtered out and the reader will report a No-Read.
Bar Code Size •
Min Narrow Element (mils)/Max Narrow Element (mils)/Maximum Tilt
•
These entries are used to identify valid Quite Zones.
DRX Settings The DRX settings typically will not need to be modified. Transmit QQ The Minimum QQ is the smallest allowable QQ value for a code to be transmitted. The Maximum QQ forces the transmission of a code after the maximum QQ value is reached. See also: Modify Settings > Advanced in Appendix C.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 88
Modify Settings > Raster Use Modify Settings > Raster to define the laser sweep area of an AL5010 with the optional adjustable raster feature. It also allows you to set the oscillating frequency (speed) of the vibrating mirror. The sweep of the laser is determined by the amount of coverage your application requires (possible label position) and the distance of the laser scanner from the object being scanned. The laser sweep is adjustable from 20-degrees above 0 (the center laser position) or -20-degrees below 0. Examples: •
If the Upper Sweep is set to 15-degrees and the Lower Sweep is set to 10-degrees, the total coverage will be 25-degree encompassing 0.
•
If the Upper Sweep is set to -5-degrees and the Lower Sweep is set to -15-degrees, the total coverage will be 10-degrees, but below the 0 position.
•
If the Upper Sweep and Lower Sweep are both set to -10 degrees, the laser will remain static at 10-degrees below the 0 position.
To Set the Sweep of the Laser: 1. Enter a value in the Upper Sweep text field between -20 and 20. 2. Enter a value in the Lower Sweep text field between -20 and 20. 3. Click Update. 0. To Set the Oscillating Frequency: 1. Enter a value in the Oscillating Frequency text field between 0 and 4. A value of 0 will stop oscillation, while values above 0 will increase the speed of the oscillation up to the fastest at a value of 4. 2. Click Update. 0. See also: Chapter 3: Mechanical Installation > Raster Setup.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 89
Save / Retrieve Use Save/Retrieve to save all the settings to the scan head and backup the settings to the mounting base and/or file. To use the save/retrieve functions: 1. Select an Action. Based on the action selected, either the From or To drop-down list becomes available. 2. Select the required location (either From or To). 3. Follow any additional prompts. For example: If Retrieve from File is selected, use the Browse function provided to locate the file. 4. Click OK. 0. Default Use to return the reader’s parameters to the hard-coded "default" values built into the reader software. USEFUL TIP: Selecting Default will return your reader to the default factory settings. Since your reader may already be configured for your application, it is recommended that you ALWAYS Save to Disk before using the default function.
Retrieve from Base Use to retrieve the parameters stored in the reader’s mounting base. This is especially useful when it becomes necessary to load the correct parameters to a replacement reader module. Retrieve from File Use to retrieve a parameters set from a specific file name and location on your computer. Save to Base Use to save the current set of parameters to the mounting base as a backup copy. Save to File Use to specify a file name and location to store the current parameter settings on your computer. Save to Reader Use to save the current set of parameters to the reader. Parameters saved in the reader are the parameters used during normal operations. Reboot AL5010 Click Reboot to reinitialize the scanner. See also: Save / Retrieve in Appendix C.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 90
Diagnostics The AL5010 includes comprehensive diagnostic that enable you to monitor: •
Status LEDs
•
Read Quality
•
Messages
•
Box Information
•
Message Monitor
•
Read Rate Log
•
Counters Log
•
Message Log
•
Upload Firmware
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net