Page 1 of Zetron 1708 Spec Sheet

Spec sheet · Zetron

Zetron 1708 Spec Sheet

Spec sheet4 pagesPDF 1.2 MB

All 4 pages are below, each with its text.

Download the PDF1.2 MB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Four-page spec sheet (April 2011) for the Zetron radio SCADA and telemetry system: the Model 1700 controller and the Model 1708 and 1716 remote terminal units (RTUs). It describes how the system monitors and controls remote sites by radio, the connections, the I/O of each unit, the NEMA case and battery options, and the specifications.

Device
Remote terminal unit (RTU) for radio SCADA and telemetry, collecting contact, pulse and analog signals at remote sites p. 1
Digital inputs
1708: 8 dry contact closure inputs (M1716: 16) p. 4
Control outputs
1708: 8 open collector outputs, 100mA typical sink current (M1716: 16) p. 4
Analog inputs
1708: 4 inputs, 8 bit, 256 level AD converter (M1716: 8) p. 4
Analog outputs
Model 1716 only: 4 outputs, 0-5VDC p. 4
Power
13.8VDC nominal, 10.5-16VDC; 75mA typical, 150mA max @ 16VDC; usually from the radio's power source p. 2, 4
Radio signaling
1200 Baud FFSK on any voice radio; connects by PTT, transmit, receive, ground and carrier detect (COR) p. 2, 4
Radio types
Lease lines, conventional or trunking radios, licenseless spread spectrum data radios; simplex, half-duplex or full-duplex, through repeaters p. 1
MODBUS
Optional MODBUS firmware lets the M1708 talk to spread spectrum radios through its RS-232 ports without an M1700 p. 1
Size and weight
Standard case 7.55" W x 10.5" D x 2.25" H, 2 lbs p. 4
Operating temperature
0-60 degrees Celsius p. 4
NEMA cases
Model 1795 steel NEMA 4, 20" x 24" x 8"; Model 1796 fiberglass NEMA 4X, 20" x 24" x 8"; Model 1797 fiberglass NEMA 4X, 13" x 15" x 6" p. 3
Software
Lookout: Pentium class PC at 90MHz or faster, 32 MB RAM, Windows 95 or later, 45 MB free disk space p. 4

What this sheet walks you through

  • How the controller, RTUs and control program form a SCADA system p. 1
  • Connecting the RTU to a radio and sensors p. 2, 3
  • Relaying data through RTUs (store and forward) p. 1
  • Operating over trunked radio systems p. 2
  • Choosing a NEMA case and battery backup p. 3

Good to know

  • Store and forward relaying works on conventional or trunked radio only. p. 1
  • Higher voltages need an industrial relay; the sensors should give 0-5VDC or a Form C contact closure. p. 2
  • The battery backup option does not include the radio and antenna. p. 3
  • The control software needs a dedicated PC with hard disk. p. 2

Questions this sheet answers

How many inputs does the Zetron 1708 RTU have?

8 digital (dry contact) inputs and 4 analog inputs, plus 8 open collector control outputs; the 1716 doubles these. p. 4

What voltage does the Zetron 1708 need?

13.8VDC nominal, within 10.5-16VDC, drawing 75mA typical and 150mA max. p. 4

Does the Zetron 1708 support MODBUS?

With the optional MODBUS firmware it talks to spread spectrum radios through its RS-232 ports, without an M1700 interface. p. 1

Does the Zetron 1708 have analog outputs?

No; the 4 analog outputs are on the Model 1716 only. p. 4

The file

Size and text

Pages4
PDF1.2 MB
TextText from the PDF itself.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Zetron 1708 Spec Sheet

The text of page 1, from the PDF itself

Model 1700 Controller Model 1708/1716 RTUS

Spec Sheet

FEATURES

  • Economical SCADA and Telemetry
  • Up to 44 I/O Points per RTU
  • Report-by-Exception
  • Programmable Polling
  • Operates on Lease Lines, Conventional or Trunking Radios
  • Use with Licenseless Spread Spectrum Data Radios
  • Store and Forward

The Model 1700 system controller is located at the central site and is connected between the central radio and a PC. The controller sends and receives data between the central PC and the remote sites.

INTRODUCTION

FEATURE DESCRIPTION

Zetron SCADA (Supervisory Control and Data Acquisition) and telemetry system offers practical, economical monitoring and control remote sites via radio. The SCADA System is comprised of 3 parts: Remote Terminal Units (RTUs), System Controller, and Control Program.

Store and Forward

Zetron RTUs such as the Model 1708 and Model 1716, are units typically installed at remote sites to collect data from contact closures, pulse counters, and analog voltage or current signals. RTUs also offer digital and analog outputs for remote control of process variables. The inputs/outputs can monitor and control level, pressure, temperature, security, power etc. from switches or transducers. Zetron RTUs detect changes in input signals and transmit exception reports immediately, when polled by the Controller, or both. Once the Control Program sees a data change, it can initiate corrective action by sending output commands to the same or different RTU.

The MODBUS system software is the brain of the SCADA system and allows the user to monitor, control, display, log, print, poll, etc. system data from the PC.

Model 1708 and 1716 RTUs can rebroadcast data sent from other RTUs and the Model 1700 controller. (Conventional or Trunked Radio only) This augments installations that do not have 100% radio coverage from the central office, any RTU can relay information between the Model 1700 controller and an out of range RTU.

User Configurable Features such as key delay, channel busy indication, I/O parameters are all definable by the user. Zetron SCADA can operate on simplex, half-duplex, fullduplex, trunking or conventional radios, and through repeaters.

Optional MODBUS Firmware The M1708 and M1716 RTUs can communicate with spread spectrum radios via the RS-232 ports. The system can use licensee free radios that result in a faster exchange of data between the PC or PLC and the RTUs. It also eliminates the need for a M1700 interface.

Page 2 of Zetron 1708 Spec Sheet

The text of page 2, from the PDF itself

All Call

turn communicates with the remote terminal units, M1708 and M1716s. Existing SCADA systems or PLCs utilizing MODBUS can also control the M1700.

A second ID number can be assigned to a group or groups of RTUs.

There are a number of highly productive automation software packages that can be used to control, monitor, analyze, or report on your industrial automation applications. These include an extensive library of graphics, Internet connection with the web client feature, trending data display, dial out alarms to a commercial paging service and much more.

This allows for the rapid control of a large number of RTU’s outputs. This is ideal for siren control.

Trunked Operation A software switch enables the SCADA system to operate over trunked radio systems. Since each Remote has its own unit number, a single trunking ID code is all the Zetron SCADA needs. Trunked system operators can now offer their customers security and control functions.

CONNECTIONS/INSTALLATIONS The 1700 controller connects to the RS-232 serial port of the PC or terminal using transmit, receive, and ground. Both the M1708 and M1716 RTUs and the M1700 Controller connect to the radio using PTT, transmit, receive, ground and carrier detect (COR). The units operate from 12VDC, usually supplied by the radio’s power source. The sensors being monitored by the M1708/1716 RTUs at the remote site should provide 0-5VDC, 0-20mA, or Form C contact closure to ground or open to 100Kohms impedance. Higher voltages can be controlled via the appropriate industrial relay. The control software requires a dedicated PC with hard disk. A printer is not required since all information is logged on disk.

Fast, Accurate Reporting All communications are two-way using fast frequency shift keying, FFSK. Each data burst lasts less than a second, yet contains all the data, plus an advanced error detection scheme. The FFSK protocol operates on any voice radio (true digital or NRZS modulation capability is not required). This eliminates the falsing common to DTMF and minimizes usage of valuable airtime.

SCADA SOFTWARE The Zetron SCADA System can communicate with and be controlled by process control applications or programmable logic controllers (PLC) via the MODBUS communications protocol. MODBUS is an industrial industry standard communications protocol allowing devices from different manufacturers to communicate. The MODBUS protocol can control and monitor the M1700 control hardware, which in

FLEXIBLE COMMUNICATIONS OPTIONS

Page 3 of Zetron 1708 Spec Sheet

The text of page 3, from the PDF itself

STANDARD CONNECTIONS Radio Transmit Data Receive Data Push-to-Talk Channel Busy Power Ground +12 Volts DC Serial Port RS-232 Data In RS-232 Data Out

BATTERY BACKUP Users can order the RTUs integrated with NEMA cases and battery backup. This option features:

  • 7 AH 12 volt lead acid cell battery for power loss backup operation
  • Battery charger
  • 2-amp power supply
  • Wiring cables connecting battery, supply, RTU, radio (radio and antenna are not included)

INDUSTRIAL NEMA CASES Order one of the three models of NEMA cases:

  • Model 1795 is a steel NEMA 4 case, size 20” x 24” x 8”, wiring cables, backplane size 17” x 21”, 7AH battery, 2 amp charger/ supply.
  • Model 1796 is a fiberglass NEMA 4X case, size 20” x 24” x 8”, wiring cables, backplane size 17” x 21”, 7AH battery, 2 amp charger/supply.
  • Model 1797 is a fiberglass NEMA 4X case, size 13” x 15” x 6”, wiring cables, backplane size 11” x 13”, 7AH battery, 2 amp charger/supply. The RTUs are attached to a custom metal backplane with a mounting area for mobile or handheld radios, heaters, industrial relays, signal conditioners, or other industrial electronics required for the application. The customer only needs to drill and mount an external antenna, drill and connect external power, and install radio to the metal backplane via mounting holes. M1700

M1708

M1716

DIGITAL INPUTS Pulse Counter

­ - 816CONTROL OUTPUTS4816

ANALOG INPUTS Accumulator, 4

8

ANALOG OUTPUTS, - 4

Page 4 of Zetron 1708 Spec Sheet

The text of page 4, from the PDF itself

SPECIFICATIONS Model 1708/1716 RTU 8 Digital inputs: 16 for M1716 Dry contact closure 8 Control outputs: 16 for M1716 Open collector type VCC minus 1 volt @ 100mA 100mA typical sink current 4 Analog inputs: 8 for M1716 0-5VDC or 4-20mA 8 bit, 256 level AD converter 4 Analog outputs: Model 1716 only 0-5VDC Model 1700: 4 Control outputs Open collector type Communication Specifications Radio Interface: PTT, COR Input levels from 20mV to 3Vpp Input impedance > 30Kohm @ 1KHz Output level 3Vpp maximum with 10Kohm load Output impedance < 1Kohm @ 1KHz Flat audio in and flat audio out Transmit audio adjustable from 20mv to 2V p-p COR adjustable from 0.1 to 4.5VDC PTT output relay to ground < 300mA max, NO or NC position Signaling at 1200 Baud FFSK RS-232 Interface:

Power: Optional Power Supply
TX, RX & ground 4800 baud 8 bit with one stop bit and no parity VT100 or similar monitor compatible No hardware or software flow control 13.8VDC nominal, 10.5-16VDC 75mA typical, 150mA max @ 16VDC

Physical Specifications 1700/1708/1716 Standard Case Size: 7.55” W x 10.5” D x 2.25” H Weight: 2 lbs Temperature Specifications Operating: 0-60 degrees Celsius Approvals FCC Part 15 Lookout Software Requirements Pentium class PC running at 90MHZ or faster 32 MB RAM Windows 95 or later, includes NT and XP 45 MB free disk space Power – 13.8VDC nominal, 10.5-16VDC – 75mA typical, 150mA max @ 16VDC Optional Battery/Charger/Power Supply – Battery 12V, 12amp-hr, lead-acid cell – Charger 500mA float charge, 2-amp max fast charge – Short circuit protected – AC power: 115VAC, 0.7 Amp max Physical Specifications 1700/1708/1716 Standard Case Size 7.55” W x 10.5” D x 2.25” H Weight 2 lbs Temperature Specifications Operating 0-60 degrees Celsius Approvals FCC Part 15

Battery 12V, 12amp-hr, lead-acid cell Charger 500mA float charge, 2-amp max fast charge Short circuit protected AC power: 115VAC, 0.7 Amp max

ZETRON AMERICAS PO Box 97004, Redmond, WA USA 98073-9704 (P) 1 425 820 6363 (F) 1 425 820 7031 (E) zetron@zetron.com ZETRON EMEA 27-29 Campbell Court, Bramley, Hampshire RG26 5EG, United Kingdom (P) +44 1256 880663 (F) +44 1256 880491 (E) uk@zetron.com ZETRON AUSTRALASIA PO Box 3045, Stafford Mail Centre, Stafford QLD 4053, Australia (P) +61 7 3856 4888 (F) +61 7 3356 6877 (E) au@zetron.com

©Zetron, Inc. All rights reserved. Zetron® and Zetron and Design® are registered trademarks of Zetron, Inc. All other trademarks are properties of their respective owners. See Zetron price list for option pricing. Specifications subject to change without notice.

005-1318D April 2011