The text of a manual · part 1 of 4
UCLI72-4 Quad Charger, pages 1 to 8
Pages 1 to 8 of 32
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Zebra UCL172-4
Page 1
UCLI72-4 Quad Charger Chargeur quadruple UCLI72-4 Cargador cuádruple UCLI72-4
UCLI72-4 四座充电器
Зарядное устройство на четыре аккумулятора UCLI72-4
English ................................................................................... 2 Français ................................................................................. 7 Español ................................................................................ 12 汉语 ...................................................................................... 17 한국어 .................................................................................. 22 Русский ................................................................................. 27
Page 2
UCLI72-4 Quad Charger Important Charger and Battery Safety Information
Keep this guide available. It contains important safety and operating information.
Battery Safety
Caution • Short Circuits
Avoid accidental short circuiting of any battery. Allowing battery terminals to contact conductive material will create a short circuit which could cause burns and other injuries or could start a fire.
Caution • Don’t Use Damaged Batteries
Never attempt to charge a battery that is visibly damaged or is emitting odors.
Caution • Always Use Zebra Battery Packs
Use of any batteries not approved specifically for use with this charger could cause damage to the battery or the charger and will void the warranty.
Important • Observe Battery Safety Precautions
Always observe the safety precautions in the Lithium-ion Technical Bulletin included with each Battery Pack. Important • Battery Disposal Always dispose of used batteries in accordance with local regulations. Placing used batteries into the trash or the municipal waste stream may be illegal in your area. Insulate battery contacts with a piece of tape prior to disposal.
Charger Safety
Caution • Use the Correct Zebra Charger
Only charge the supported battery pack types designated for use with this charger. Use of any battery charger not approved specifically by Zebra for use with its batteries could cause damage to the battery pack or the printer and will void any equipment warranty.
Caution • Correct Voltage
Ensure that the Battery Charger is configured for the A.C. voltage used in your area and you are using the correct A.C. power cord and/or power supply for the intended country of use. Use the charger with the supplied power supply only, which must be plugged into an earth grounded outlet.
Important • Charger Location
• Use care in locating the Charger. Do not place it in locations where liquids or metallic objects may be dropped into the charger. Never locate the charger near any source of combustion. • Do not block the ventilating slots on the top and bottom covers. • Ensure that the Charger is plugged into a power source that won’t accidentally be turned off if you will be charging batteries overnight.
Important • Indoor Use Only
This charger is intended for indoor use only.
Important • Charger Maintenance
• Clean only with a dry or slightly damp, lint free cloth. • Never operate a charger that has been damaged in any way. • Do not disassemble the battery packs or the charger. There are no user serviceable components inside.
Charger Specifications
The power supply is compatible with all common AC supply voltages. AC voltage setting is automatic. Power Supply Specifications Charger Operating Temperature
Input
100-240 VAC @ 1.2 AMPS Max., 47-63 Hz
Output
1 12.0V +/- 50 mV @ 4 AMPS Max.
During Charge In Storage
0 o C to 40 o C -40 oC to 70 o C
UCLI-4 Charger Manual pg. 2
Page 3
Keep these instructions readily accessible. This manual contains important safety and operating instructions. To reduce the risk of battery explosion, follow these instructions and those included with the battery
The Zebra UCLI72-4 Lithium-Ion Quad Charger is designed to charge up to four Lithium-Ion (Li-Ion) QL or RW series Mobile Printer battery packs simultaneously. The unit is supplied with an external power supply compatible with all common A.C. supply voltages. A.C. voltage setting is automatic. Refer to the Setup and Specifications Sections on the following pages for more details.
Power Cord
QL or RW series Battery Pack
Power Supply
Fast
Charg
Fault Replace e
Batte
Full ry
Charg Read e y Fast
Charg
Fault Replace e
Batte
Full ry
Charg Read e y Fast
Charg
Fault Replace e
Batte
Full ry
Charg Read y e
Fast
Charg
Fault Replace
Charge Indicators e
Batte
Full ry
Powe
Charg Read e y r
Power Indicator
UCLI-4 Charger Manual pg. 3
Page 4
Setting up the Charger Place the Quad Charger on a surface near an A.C. outlet. There are four mounting holes in the bottom of the charger which allow it to be secured to a table or shelf to help ensure the charging process will not be interrupted by someone inadvertently moving or unplugging either the charger or the battery packs under charge. Plug the circular four pin plug from the power supply into the back of the charger. Plug one end of the power cord into the Power Supply and the other into an earth grounded A.C. power source. The power indicator on the front panel should come on, indicating the Quad Charger is ready for use.
Charging Batteries Ensure that the Charger is plugged into a power source which won’t accidently be turned off if you will be charging batteries overnight. Ensure that the power indicator on the front panel is on before charging batteries. Plug a battery pack into any one of the four charging bays as shown. Note the orientation of the battery pack. Slide the battery pack into the charging bay until it stops. Then rock the battery pack back until it snaps into place. The amber indicator directly under the battery being charged will turn on if the battery is properly inserted. The charger will perform an automatBattery Pack ic charging cycle on inserted battery packs. First it will perform a “Fast Charge” to bring the batteries up to a usable voltage as quickly as possible. Once 80% of the charge voltage has been reached, the charger switches over to a slower rate to finish charging the battery. The Amber indicator reports Charger Bay the status of the battery under charge. If on steadily, it indicates the battery is undergoing a “Fast Charge”; if off, it indicates that the battery is fully charged. If the Amber indicator is flashing, it indicates a problem with the battery. The battery may be too hot or cold to be charged reliably. Try to charge the battery again when it returns to the room’s ambient temperature. If the Amber indicator starts flashing on the Amber Indicator second attempt, the battery Full Charge Fast Charge should be discarded. The Green indicator reports Ready Faultthe charging status. If it is Replace Battery flashing, and the Amber indiGreen Indicator cator is lit steadily, it reports Fas t Ch arg
Fau Rep ltlace B e atte
Full ry
Cha
Rea rge dy
Fas t Ch arg
Fau Rep ltlace B e atte
Full ry
Cha
Rea rge dy
Fas t Ch arg
Fau Rep ltlace B
UCLI-4 Charger Manual pg. 4 e atte
Full ry
Cha
Rea rge dy
Fas t Ch arg
Fau Rep ltlace B e atte
Full ry
Pow er
R
Page 5
that the charger has completed the fast charge part of the charging cycle and is now “topping off” the battery at a slower charge rate. The battery pack is usable at this point although it would be more desirable to wait until the battery is full charged. If the green indicator is lit steadily, and the Amber indicator is off, the battery pack is fully charged. Refer to the chart below for a quick reference: Amber
Green
On
Off
Battery Status Charging
On
Flashing
O.K. (80% charged)
Off
On
Completely Charged
Flashing
Off
Fault-Replace Battery
Supported Batteries and Charging Times The Zebra UCLI72-4 Quad Charger supports the battery packs listed in the following table. The times in the following table are for completely discharged batteries. Partially discharged battery packs will take less time to reach a charged state. QL 220;QL 320 (AT16004-1) & RW 220 (CT17497-1)
QL 420 (AT16293-1) & RW 420 (CT17102-2)
80% charge
1.25 hrs
2.5 hrs.
Full Charge
2.5 hrs
5 hrs.
The Quad Charger has a safety feature which stops charging a battery after six hours regardless of its charge state.
Battery Recycling
The EPA certified RBRC® Battery Recycling Seal on the Lithium-Ion (LiIon) battery supplied with your printer indicates Zebra Technologies Corporation is voluntarily participating in an industry program to collect and recycle these batteries at the end of their useful life, when taken out of service in the United States or Canada. The RBRC® program provides a convenient alternative to placing used Li-Ion batteries into the trash or the municipal waste stream, which may be illegal in your area. Please call 1-800-8-BATTERY for information on Li-Ion battery recycling and disposal bans/restrictions in your area. Zebra Technologies Corporation’s involvement in this program is part of our commitment to preserving our environment and conserving our natural resources. Outside North America, please follow local battery recycling guidelines.
UCLI-4 Charger Manual pg. 5
Page 6
FCC Disclaimer
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Liability Disclaimer
Inasmuch as every effort has been made to supply accurate information in this manual, Zebra Technologies Corporation is not liable for any erroneous information or omissions. Zebra Technologies Corporation reserves the right to correct any such errors and disclaims liability resulting therefrom.
No Liability for Consequential Damage
In no event shall Zebra Technologies Corporation or anyone else involved in the creation, production, or delivery of the accompanying product (including hardware and software) be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or other pecuniary loss) arising out of the use of or the results of use of or inability to use such product, even if Zebra Technologies Corporation has been advised of the possibility of such damages. Because some states do not allow the exclusion of liability for consequential or incidental damages, the above limitation may not apply to you.
Product Support Contacts In the Americas contact Regional Headquarters
Technical Support
Customer Service Dept.
Zebra Technologies International,LLC 333 Corporate Woods Parkway Vernon Hills, Illinois 60061.3109 U.S.A T: +1 847 793 2600 Toll-free +1 800 423 0422
T: +1 847 913 2259 F: +1 847 913 2578 Hardware: hwtsamerica@zebra.com Software: swtsamerica@zebra.com
For printers, parts, media, and ribbon, please call your distributor, or contact us. T: +1 866 230 9494 F: +1 847 913 8766 E: VHCustServ@zebra.com
In Europe, Africa, the Middle East, and India contact Regional Headquarters
Technical Support
Internal Sales Dept.
Zebra Technologies Europe Limited Zebra House The Valley Centre, Gordon Road High Wycombe Buckinghamshire HP13 6EQ, UK T: +44 (0)1494 472872 F: +44 (0) 1494 450103
T: +44 (0) 1494 768298 F: +44 (0) 1494 768210 Germany: Tsgermany@zebra.com F: +44 (0) 1494 768244 E: mseurope@zebra.com France:: Tsfrance@zebra.com Spain/Portugal: Tsspain@zebra.com All other areas: Tseurope@zebra.com
For printers, parts, media, and ribbon, please call your distributor, or contact us. T: +44 (0) 1494 768316 F: +44 (0) 1494 768244 E: mseurope@zebra.com
Regional Headquarters
Technical Support
Customer Service
Zebra Technologies Asia Pacific, LLC 16 New Industrial Road #05-03 Hudson TechnoCentre Singapore 536204 T: +65 6858 0722 F: +65 6885 0838
T: +65 6858 0722 F: +65 6885 0838 E: tsasiapacific@zebra.com
For printers, parts, media, and ribbon, please call your distributor, or contact us. T: +65 6858 0722 F: +65 6885 0837
In the Asia Pacific region contact
UCLI-4 Charger Manual pg. 6
Page 7
Chargeur quadruple UCLI72-4
Important - Informations de sécurité concernant le chargeur et les batteries Conservez ce guide a portée de main. II contient d'importantes informations de sécurité et de fonctionnement.
Sécurité de la batterie
/\ Attention * Courts-circuits Evitez de court-circuiter accidentellement une batterie. Si les contacts de /a batterie touchent un matériau conducteur, il se produira un court-circuit pouvant causer des briilures, des blessures ou un incendie. Attention N'utilisez pas les batteries détériorées Ne tentez jamais de recharger une batterie visiblement endommagée ou dégageant une odeur. Attention ¢ Utilisez toujours des batteries Zebra Le fait de recharger des batteries non spécifiquement approuvées dans ce chargeur peut endommager la batterie ou le chargeur et annulera la garantie.
( Important * Respectez les précautions de sécurité de la batterie Respectez les précautions de sécurité figurant dans le bulletin technique sur les batteries Lithium-ion qui accompagne chaque batterie. Important * Mise au rebut de la batterie Mettez toujours les batteries usagées au rebut en vous conformant aux réglementations locales. I! est possible que dans votre région il soit interdit de jeter des batteries usagées dans les ordures ménagéres. Avant de jeter une batterie, isolez ses contacts avec du ruban adhésit.
Sécurité du chargeur Attention ¢ Veillez a utiliser le chargeur Zebra approprié Rechargez seulement les types de batteries prévus pour ce chargeur. L'utilisation d'un chargeur non spécifiquement approuvé par Zebra peut endommager Ia batterie ou I'imprimante et annulera la garantie de l'appareil. Attention * Tension correcte Assurez-vous que le chargeur est correctement configuré pour la tension du secteur alternatif local et que vous avez le bon cordon et la bonne alimentation pour le pays d'utilisation. N'utilisez le chargeur qu’avec le bloc d‘alimentation fourni raccordé au secteur par une prise reliée a la terre. ( Important * Emplacement du chargeur © Soyez prudent dans le choix de I‘emplacement du chargeur. Ne le placez pas a un endroit ou des liquides ou des objets métalliques pourraient tomber a I'intérieur. Ne placez jamais le chargeur prés d'une source de combustion. ¢ Nobstruez pas les fentes de ventilation des couvercles supérieur et inférieur. ¢ Assurez-vous que le chargeur est raccordé a une alimentation ne risquant pas d’étre accidentellement coupée si vous rechargez des batteries pendant la nuit. Important * Usage intérieur uniquement Ce chargeur ne doit étre utilisé qua I’ intérieur. Important * Entretien du chargeur ¢ Nettoyez uniquement avec un chiffon non pelucheux, sec ou légérement humide. ¢ N'utilisez jamais un chargeur qui présente des dommages quelconques. ¢ Ne cherchez pas a démonter les batteries ou le chargeur. Ils ne contiennent aucune piéce réparable par l'utilisateur.
Spécifications du chargeur Le bloc d’alimentation est compatible avec toutes les tensions répandues de courant alternatif. Le réglage de la tension en c.a. est automatique.
Spécifications du bloc Entrée | 100-240 V.c.a. a 1,2 A max., 47-63 Hz d’alimentation Sortie | 112,0V +/-50 mV a4 A max.
Température de En cours de charge | De 0°C a 40°C fonctionnement du chargeur En stockage | De -40°C a 70°C
Manuel du chargeur UCLI-4 7
Page 8
() Conservez ces consignes a portée de main. Ce manuel contient d’importantes consignes de sécurité et instructions d'utilisation. Pour réduire le risque d‘explosion de la batterie, respectez ces consignes et celles qui accompagnent la batterie.
Le chargeur quadruple de batteries au Lithium-lon Zebra UCLI72-4 permet de recharger jusqu’a quatre batteries au Lithium-lon (Li-lon) d’imprimantes portables QL ou RW simul-tanément. L'appareil est fourni avec une alimentation extérieure compatible avec toutes les tensions répandues de courant alternatif. Le réglage de la tension en c.a. est automatique. Pour des informations détaillées, reportez-vous aux sections Configuration et Spécifications des pages suivantes.
Cordon d‘alimentation
Batterie d’imprimante QL ou RW
Bloc d‘alimentation
Témoins de charge
Témoin d‘alimentation
Manuel du chargeur UCLI-4 8