Page 21
S400 & S600 User’s Guide
Ribbon Loading Instructions NOTES: n Zebra recommends the use of ribbon that is wider than the media. The smooth backing of the ribbon protects the printhead from wear and premature failure due to excessive abrasion. (For the direct thermal print method, ribbon is not used and should not be loaded in the printer.)
n Zebra recommends the use of ribbon that is outside wound (the ink side is on the outside of the roll).
To load ribbon, see Figure 12 and follow the procedure below. 1. Adjust the ribbon supply spindle position for normal or low tension. 2. Align the blades (b) on the two sections of the spindle as shown in Figure 11. (You do not need to do this if your ribbon width is 2.4" [60 mm] or less.) 3. Place the ribbon roll on the ribbon supply spindle (a). Make sure the roll is pushed in to the stop at the end of the spindle. 4. Open the printhead by moving the head open lever (b) counterclockwise to the open position. 5. Thread the ribbon as shown. Wind the ribbon onto the ribbon takeup spindle (c) for several turns in a clockwise direction until wrinkles and creases disappear. 6. Close the printhead by moving the lever clockwise to the closed position.
21
13
Page 22
14
S400 & S600 User’s Guide
Ribbon Removal Refer to Figure 12. When it’s time to change the ribbon, cut the ribbon where it is stretched between the upper ribbon guide arm and the takeup spindle. To remove ribbon from the takeup spindle, press the release button (d) and slide the ribbon off the spindle.
c b a d
Figure 12
22
Page 23
S400 & S600 User’s Guide
Adjusting the Media Sensor This adjustment aligns the position of the light sensor with the notch or edge of the label, so the printer can determine the correct label size. See Figure 13. With the printhead open, look through the side of the print mechanism and locate the media sensor adjustment lever (a). Reposition the sensor until the top of the adjustment lever is in line with the notch or web in the media or the edge of the label. Close the printhead by moving the head open lever to the closed position. When continuous media (no notch or opening to sense) is used, position the media sensor anywhere over the media so that an “out-of-media” condition will still be sensed. Non-Continuous Media
This type of media has some type of physical characteristic (web, notch, perforation, etc.) that indicates the start/end of each label. The media sensor must be properly positioned to sense these indicators. See “Adjusting the Media Sensor” (above). Then, turn on the printer. If the printer will not auto calibrate, press the MODE button three times, and then the FEED button once, to manually calibrate (a label will print that shows the sensor profile). Continuous Media
Since continuous media does not contain label start/end indicators, you must tell the printer via software how long each label is. If you are using ZPL or ZPL II, include a Label Length (^LL) instruction in each label format you send to the printer (refer to your ZPL II Programming Guide). If you are using other software to operate your printer, refer to the instructions provided with that software.
a
Figure 13
23
15
Page 24
16
S400 & S600 User’s Guide
Auto Calibration This procedure occurs whenever the printer is turned on or the printhead is opened and closed. During this procedure, the printer automatically determines the media type, label length, media and ribbon sensor settings, and printing method (direct thermal or thermal transfer). This procedure is set at the factory but may be changed via ZPL II command. NOTE: If the printer fails to auto calibrate when you are using pre-printed labels or pre-printed label backing, or if the printer will not auto calibrate, see “Manual Calibration” in Troubleshooting. 1. Load the media and ribbon (if used). 2. Turn on the printer power. 3. Two or three blank labels will feed, completing auto calibration.
Operator Controls Front Panel Buttons Refer to Figure 14. PAUSE Button n Starts and stops the printing process. n The first time the button is pressed, any partially printed label is completed; then, the printing process is stopped. n If the printer is idle when the button is pressed, no new print requests are printed until PAUSE is pressed again. FEED Button (also referred to as the UP button) n Forces the printer to feed one blank label. n If the button is pressed when the printer is idle or paused, a blank label immediately feeds. n When the button is pressed while the printer is printing, one blank label feeds after the completion of the current batch of labels.
n Once the blank label has been fed, pressing the button again will feed a second label. n When in the configuration mode, functions as the UP button.
CANCEL Button (also referred to as the DOWN button) n This button only functions when the printer is paused.
24
Page 25
S400 & S600 User’s Guide n If the button is pressed, the label format that is currently printing is canceled.
POWER n If pressed when no label format
PRINTHEAD is printing, then the next format to be printed is canceled.
PAPER/RIBBON n Press for at least three seconds to cancel all label formats the printer has received and return the printer to an idle state.
PAUSE n When in the configuration mode, functions as the DOWN button.
FEED
MODE Button n Puts the printer into the configuration mode. n Used to change print darkness and media position, and to calibrate the printer. Front Panel LEDs DATA
Refer to Figure 14. The front panel LEDs give you a quick indication of the printer’s current status. During normal operation, the POWER LED is on and all other LEDs are off. For all other conditions, please refer to Troubleshooting. Now, you’re ready to turn on the printer!
CANCEL DARKEN POSITION CALIBRATE
MODE
Figure 14
25
17
Page 26
18
S400 & S600 User’s Guide
AC Power ON/OFF Switch This switch is located on the left side of the printer near the AC power cord and fuse (see Figure 6). The AC power switch should be turned off before connecting or disconnecting any cables. Turning the switch on activates the printer and causes it to perform a Power ON Self Test, which can take up to 30 seconds, as it begins operation. Turning the printer power on while holding down certain front panel keys will activate additional printer self tests following the Power ON Self Test. See Troubleshooting. External influences, such as lightning storms or unwanted noise on the power or data cables, may cause erratic printer behavior. Turning the AC power off and back on may re-establish proper printer operation. Otherwise, see Troubleshooting.
Printing a Test Label Before you connect the printer to your computer, make sure that the printer is in proper working order. You can do this by printing a configuration label (refer to the “CANCEL Key Self Test” in Troubleshooting.) If you can’t get this label to print, refer to Troubleshooting. To make print quality adjustments, refer to “Print Quality Adjustments” in Routine Care and Adjustments.
Connecting the Printer and Computer This printer comes with both a nine-pin Electronics Industries Association (EIA) RS-232 serial data interface and an IEEE 1284 bi-directional parallel data interface. In either case, you must supply the required interface cable for your application. CAUTION: This printer complies with FCC “Rules and Regulations,” Part 15, for Class B Equipment, using fully shielded six-foot data cables. Use of longer cables or unshielded cables may increase radiated emissions above the Class B limits. RS-232 Interface Requirements Refer to Figure 6. The required cable must have a 9-pin “D” type (DB-9P) connector (male) on one end, which is plugged into the mating (DB-9S) connector (female) located inside the access opening on the left side of the printer. The other end of the signal interface cable connects to a serial port at the host computer. This cable will be one of two types -- standard or null modem -- depending on the specific interface requirements.
26
Page 27
S400 & S600 User’s Guide
For pinout information, as well as information on how to interconnect to either a DTE or DCE device, refer to the Appendix. Parallel Interface Requirements Refer to Figure 6. An IEEE 1284 compatible bi-directional parallel data cable is required when this communication method is selected. The required cable must have a standard 36-pin parallel connector on one end, which is plugged into the mating connector located inside the access opening on the left side of the printer. The parallel interface cable is connected using bail clips instead of screws. The other end of the parallel interface cable connects to the printer connector at the host computer. For pinout information, refer to the Appendix. Serial and Parallel Cabling Requirements Data cables must be fully shielded and fitted with metal or metallized connector shells. Shielded cables and connectors are required to prevent radiation and reception of electrical noise. To minimize electrical noise pickup in the cable: 1. Keep data cables as short as possible. 2. Do not bundle the data cables tightly with power cords. 3. Do not tie the data cables to power wire conduits.
Communicating with the Printer Via the Parallel Port n Set the parallel connection on the host computer. For instructions, refer to your computer’s user’s guide. Via the Serial Port n Set the host computer to the factory defaults of the printer: 9600 baud, 8 bit word length, no parity, 1 stop bit, and XON/XOFF. For instructions, refer to your computer’s user’s guide. NOTE: If you can’t reset the host computer communications settings, then you must establish a temporary parallel connection to send down the Set Communications (^SC) command that changes the printer’s settings to match the host settings. DEFAULTING THE PRINTER: To reset only the communications parameters on the printer to the factory defaults (9600 baud, 8 bit word
27
19
Page 28
20
S400 & S600 User’s Guide length, no parity, 1 stop bit, and XON/XOFF), press and hold the PAUSE, FEED, and MODE buttons while turning on the printer, then release the buttons when the CALIBRATE LED goes out. All of the LEDs will go on, while the DARKEN, POSITION, and CALIBRATE LEDs will flash. Press and hold the MODE button until all of the lights go out, then release the MODE button. The factory defaults have now been reset. Next, set the communications parameters on your computer to match this. NOTE: To save the default settings, press the MODE button four times. Otherwise, the previous settings will be restored the next time the printer is turned on. AUTOBAUD: To automatically detect the communications parameters, press and hold the PAUSE, FEED, and MODE buttons while turning on the printer, then release the buttons when the CALIBRATE LED goes out. All of the LEDs will go on, while DARKEN, POSITION, and CALIBRATE LEDs will flash. Send a label format using the host computer settings. If the printer accepts the host parameters, all of the LEDs will go off (except for the POWER LED) and the printer will restart with the host communication settings. If the printer does not accept the host communications parameters, the printer will not restart and the LEDs will flash on and off. If this should happen, turn the printer off and then on, and try again. NOTES: Label formats sent to the printer at this time only help the printer determine the host settings. No label will print until settings are recognized. In order for autobaud to work, your label must start with either a ^XA or ~XA ZPL II command. If all the LEDs are on, send another label format. Save the new communication settings by pressing MODE four times. Autobaud only works for 9600 baud and higher. ^SC: Use the Set Communications (^SC) command to change the communications settings on the printer. 1) With the host computer set at the same communications settings as the printer, send the ^SC command to change the printer to the desired settings. 2) Then, change the host computer settings to match the printer settings.
Setting Up the Software In order to create labels, you must decide whether you will use ZPL II or commercial label preparation software. To use ZPL II, refer to the ZPL II Programming Guide. If you choose to use a label preparation software, follow the installation instructions included in the package.
28