The text of a manual · part 11 of 13
User's Guide for the Zebra S400 and S600 Printers: Appendix
Pages 67 to 70 of 78, from User's Guide for the Zebra S400 and S600 Printers
The original document is the PDF (796 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Zebra S400 and Zebra S600
Page 67
S400 & S600 User’s Guide
Appendix RS-232 Connector Technical Information RS-232 Connector Pinouts Pin. No.
Description
1
Not used
2
RXD (receive data) input to the printer
3
TXD (transmit data) output from the printer
4
DTR (data terminal ready) output from the printer -controls when the host may send data
5
Chassis ground
6
DSR (data set ready) input to the printer
7
RTS (request to send) output from the printer -- always in the ACTIVE condition when the printer is turned on
8
Not used
9
5 V fused
NOTE: When XON/XOFF handshaking is selected, data flow is controlled by the ASCII control codes DC1 (XON) and DC3 (XOFF). The DTR control lead will have no effect. Interconnecting to DTE Devices
The printer is configured as data terminal equipment (DTE). To connect the printer to other DTE devices (such as the serial port of a personal computer), use an RS-232 null modem (crossover) cable. Figure 31 shows the required cable connections. Interconnecting to DCE Devices
When the printer is connected via its RS-232 interface to data communication equipment (DCE) such as a modem, a STANDARD RS-232 (straight-through) interface cable must be used. Figure 32 shows the connections required for this cable.
67
59
Page 68
60
S400 & S600 User’s Guide
DTE 1 2 3 4 5 6 7 8 9
DTE (RD)
(RD)
(TD)
(TD)
(DTR)
(DTR)
(SG)
(SG)
(DSR)
(DSR)
(RTS)
(RTS)
1 2 3 4 5 6 7 8 9
Figure 31
DCE 1 2 3 4 5 6 7 8 9
DTE CARRIER DETECT (CD) RECEIVE DATA (RD) TRANSMIT DATA (TD) DATA TERMINAL READY (DTR) SIGNAL GROUND (SG) DATA SET READY (DSR) REQUEST TO SEND (RTS) CLEAR TO SEND (CTS)
Figure 32
68
1 2 3 4 5 6 7 8 9
Page 69
S400 & S600 User’s Guide
Parallel Interface Technical Information Parallel Connector Pinouts Pin. No.
Description
1 nStrobe/Host Clk
2-9
Data Bits 1-8
10 nACK/PtrClk
11
Busy/Per Busy
12
PError/ACK Data Req.
13
Select/Xflag
14 nauto Fd/Host Busy
15
Not Used
16-17
Ground
18 19-30
+5V @ 1A Fused Ground
31 nlnit
32 nFault/nData Avail.
33-34
Not Used
35
+5V through 2.2KΩ Resistor
36
NSelectIn/1284 active
69
61
Page 70
62
S400 & S600 User’s Guide
Storage and Reshipping If you are not placing the printer into operation immediately, repackage it using the original packing materials. The printer may be stored under the following conditions: n Temperature: -40° to 140° F (-40 to 60° C) n Relative humidity: 5% to 85% non-condensing
To ship the printer, carefully pack it in a suitable container to avoid damage during transit. Whenever possible, use the original container from the factory. A shipping container can be purchased from Zebra Technologies Corporation, if the original one has been lost or destroyed. If you use a different container, package the printer carefully to avoid damage. CAUTION: When packaging the printer in a rigid container, use shock mounts or shock-absorbing packing material. A rigid container will allow shock on the outside to be transmitted undamped to the printer which may cause damage. Also, before packing, remove all ribbon and media from the supply and take-up spindles to prevent damage to the printer.
70