The text of a manual · part 8 of 48
DS2208 Digital Scanner Product Reference Guide: Chapter 4 Maintenance & Technical Specifications
Pages 41 to 50 of 404, from DS2208 Digital Scanner Product Reference Guide
The original document is the PDF (12 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Zebra DS2208
Page 41
CHAPTER 4 MAINTENANCE & TECHNICAL SPECIFICATIONS Introduction This chapter provides suggested digital scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts).
Maintenance IMPORTANT Use pre-moistened wipes and do not allow liquid cleaner to pool.
Known Harmful Ingredients The following chemicals are known to damage the plastics on Zebra scanners and should not come in contact with the device: • Acetone • Ammonia solutions • Aqueous or alcoholic alkaline solutions • Aromatic and chlorinated hydrocarbons • Benzene • Carbolic acid • Compounds of amines or ammonia • Ethanolamine • Ethers • Isopropyl alcohol 70% (including wipes) • Ketones • TB-lysoform • Toluene • Trichloroethylene.
Page 42
4 - 2 DS2208 Digital Scanner Product Reference Guide
Approved Cleaners • Hydrogen peroxide • Mild dish soap.
Cleaning the Digital Scanner Routinely cleaning the exit window is required. A dirty window may affect scanning accuracy. Do not allow any abrasive material to touch the window. To clean the scanner: 1.
Dampen a soft cloth with one of the approved cleaning agents listed above or use pre-moistened wipes.
2.
Gently wipe all surfaces, including the front, back, sides, top and bottom. Never apply liquid directly to the scanner. Be careful not to let liquid pool around the scanner window, trigger, cable connector or any other area on the device.
3.
Be sure to clean the trigger and in between the trigger and the housing (use a cotton-tipped applicator to reach tight or inaccessible areas).
4.
Do not spray water or other cleaning liquids directly into the exit window.
5.
Wipe the scanner exit window with a lens tissue or other material suitable for cleaning optical material such as eyeglasses.
6.
Immediately dry the scanner window after cleaning with a soft non-abrasive cloth to prevent streaking.
7.
Allow the unit to air dry before use.
8.
Scanner connectors: a.
Dip the cotton portion of a cotton-tipped applicator in isopropyl alcohol.
b.
Rub the cotton portion of the cotton-tipped applicator back-and-forth across the connector on the Zebra scanner at least 3 times. Do not leave any cotton residue on the connector.
c.
Use the cotton-tipped applicator dipped in alcohol to remove any grease and dirt near the connector area.
d.
Use a dry cotton tipped applicator and rub the cotton portion of the cotton-tipped applicator back-and-forth across the connectors at least 3 times. Do not leave any cotton residue on the connectors.
Page 43
Maintenance & Technical Specifications
Troubleshooting Table 4-1
Troubleshooting Problem
Possible Causes
The aiming pattern does not appear when pressing the trigger.
No power to the digital scanner.
If the configuration requires a power supply, re-connect the power supply.
Incorrect host interface cable is used.
Connect the correct host interface cable.
Interface/power cables are loose.
Re-connect cables.
Digital scanner is disabled.
For IBM 468x and USB IBM Hand-held, IBM Table-Top, and OPOS modes, enable the digital scanner via the host interface. Otherwise, see the technical person in charge of scanning.
If using RS-232 Nixdorf B mode, CTS is not asserted.
Assert CTS line.
Aiming pattern is disabled.
Enable the aiming pattern. See Hand-Held Decode Aiming Pattern on page 5-17.
Digital scanner is not programmed for the correct bar code type.
Program the digital scanner to read that type of bar code. See Chapter 12, Symbologies.
Bar code symbol is unreadable.
Scan test symbols of the same bar code type to determine if the bar code is defaced.
The symbol is not completely inside aiming pattern.
Move the symbol completely within the aiming pattern.
Digital scanner emits aiming pattern, but does not decode the bar code.
Possible Solutions
Move the symbol completely within the field of view (AIM pattern does NOT define FOV) Distance between digital scanner and bar code is incorrect.
Move the scanner closer to or further from the bar code. See Decode Ranges on page 3-8.
4-3
Page 44
4 - 4 DS2208 Digital Scanner Product Reference Guide
Table 4-1
Troubleshooting (Continued) Problem
Digital scanner decodes bar code, but does not transmit the data to the host.
Possible Causes
Possible Solutions
Digital scanner is not programmed for the correct host type.
Scan the appropriate host type programming bar code. See the chapter corresponding to the host type.
Interface cable is loose.
Re-connect the cable.
If the digital scanner emits 4 long low beeps, a transmission error occurred.
Set the scanner's communication parameters to match the host's setting.
This occurs if a unit is not properly configured or connected to the wrong host type.
Host displays scanned data incorrectly.
If the digital scanner emits 5 low beeps, a conversion or format error occurred.
Configure the digital scanner's conversion parameters properly.
If the digital scanner emits low/high/low beeps, it detected an invalid ADF rule.
Program the correct ADF rules. Refer to the Advanced Data Formatting Programmer Guide.
Digital scanner is not programmed to work with the host.
Scan the appropriate host type programming bar code. For RS-232, set the digital scanner's communication parameters to match the host's settings. For a Keyboard Wedge configuration, program the system for the correct keyboard type, and turn off the CAPS LOCK key. Program the proper editing options (e.g., UPC-E to UPC-A Conversion).
Digital scanner emits short low/short medium/short high beep sequence (power-up beep sequence) more than once.
The USB bus may put the digital scanner in a state where power to the scanner is cycled on and off more than once.
Normal during host reset.
Digital scanner emits 4 short high beeps during decode attempt.
Digital scanner has not completed USB initialization.
Wait several seconds and scan again.
Digital scanner emits Low/low/low/extra low beeps when not in use.
RS-232 receive error.
Normal during host reset. Otherwise, set the digital scanner's RS-232 parity to match the host setting.
Digital scanner emits low/high beeps during programming.
Input error, incorrect bar code or Cancel bar code was scanned.
Scan the correct numeric bar codes within range for the parameter programmed.
Page 45
Maintenance & Technical Specifications
Table 4-1
Troubleshooting (Continued) Problem
Digital scanner emits low/high/low/high beeps during programming.
Possible Causes
Possible Solutions
Out of host parameter storage space.
Scan Default Parameters on page 5-5.
Out of memory for ADF rules.
Reduce the number of ADF rules or the number of steps in the ADF rules.
During programming, indicates out of ADF parameter storage space.
Erase all rules and re-program with shorter rules.
ADF transmit error.
Refer to the Advanced Data Formatting Guide for information.
Invalid ADF rule is detected.
Refer to the Advanced Data Formatting Guide for information.
Digital scanner emits a power-up beep after changing USB host type.
The USB bus re-established power to the digital scanner.
Normal when changing USB host type.
Digital scanner emits one high beep when not in use.
In RS-232 mode, a <BEL> character was received and Beep on <BEL> option is enabled.
Normal when Beep on <BEL> is enabled and the digital scanner is in RS-232 mode.
Digital scanner emits frequent beeps.
No power to the scanner.
Check the system power. If the configuration requires a power supply, re-connect the power supply.
Incorrect host interface cable is used.
Verify that the correct host interface cable is used. If not, connect the correct host interface cable.
Interface/power cables are loose.
Check for loose cable connections and re-connect cables.
Conversion or format error was detected.
Ensure the scanner’s conversion parameters are properly configured.
Digital scanner emits low/high/low beeps.
Digital scanner emits five long low beeps after a bar code is decoded.
The scanner’s conversion parameters are not properly configured. Conversion or format error was detected.
Change the ADF rule, or change to a host that can support the ADF rule.
An ADF rule was set up with characters that can't be sent for the host selected. Conversion or format error was detected. A bar code was scanned with characters that can't be sent for that host.
Change the bar code, or change to a host that can support the bar code.
4-5
Page 46
4 - 6 DS2208 Digital Scanner Product Reference Guide
NOTE If after performing these checks the digital scanner still experiences problems, contact the distributor or call support.
Report Software Version Bar Code When contacting support, a support representative may ask you to scan the bar code below to determine the version of software installed in the digital scanner.
Report Software Version
Technical Specifications Table 4-2
Technical Specifications Item
Description
Physical Characteristics Dimensions
6.5 in H x 2.6 in W x 3.9 in D 16.5 cm H x 6.6 cm W x 9.8 cm D
Weight
5.7 oz. / 161.6 g
Input Voltage Range
4.5 to 5.5 VDC Host Powered; 4.5 to 5.5 VDC External Power Supply
Operating Current at Nominal Voltage (5.0V)
250 mA (typical). Note: Auto-Aim and Illumination on Acquiring Image
Standby Current (idle) at Nominal Voltage (5.0V)
150 mA (typical). Note: Auto-Aim On
Color
Nova White, Twilight Black
Supported Host Interfaces
USB, RS232, Keyboard Wedge, TGCS (IBM) 46XX over RS-485
Keyboard Support
Supports over 90 international keyboards
User Indicators
Direct Decode Indicator, Good Decode LEDs, Rear View LEDs, Beeper (adjustable tone & volume)
Performance Characteristics Motion Tolerance (Hand-Held)
Up to 5 in/13 cm per second for 13 mil UPC
Swipe Speed (Hands-Free)
Up to 30.0 in/76.2 cm per second for 13 mil UPC
Page 47
Maintenance & Technical Specifications
Table 4-2
4-7
Technical Specifications (Continued) Item
Description
Light Source
Aiming Pattern: Linear 624nm Amber LED
Illumination
(2) 645nm Super-Red LEDs
Imager Field of View
32.8° H x 24.8° V Nominal
Image Sensor
640 x 480 pixels
Minimum Print Contrast
25% minimum reflective difference
Skew Tolerance
+/- 65°
Pitch Tolerance
+/- 65°
Roll Tolerance
0° - 360°
User Environment Operating Temperature
32.0° to 122.0° F / 0.0° to 50.0° C
Storage Temperature
-40.0° to 158.0° F / -40.0° to 70.0° C
Humidity
5% to 95% RH, non-condensing
Drop Specification
Designed to withstand multiple drops at 5.0 ft. /1.5 m to concrete
Tumble Specification
Designed to withstand 250 tumbles in 1.5 ft./.5 m tumbler Note: 1 tumble = 0.5 cycle.
Environmental Sealing
IP42
Electrostatic Discharge (ESD)
ESD per EN61000-4-2, +/-15 KV Air, +/-8 KV Direct, +/-8 KV Indirect
Ambient Light Immunity
0 to 10,000 Foot Candles / 0 to 107,600 Lux
Accessories Gooseneck Intellistand
Stand for Hands-Free use
Symbol Decode Capability 1D
Code 39, Code 128, Code 93, Codabar/NW7, Code 11, MSI Plessey, UPC/EAN, I 2 of 5, Korean 3 of 5, GS1 DataBar, Base 32 (Italian Pharma)
2D
PDF417, MicroPDF417, Composite Codes, TLC-39, Data Matrix, GS1 DataMatrix, Maxicode, QR Code, GS1 QR Code, MicroQR, Aztec, Han Xin (Chinese Sensible)
Postal Codes
US Postnet, US Planet, UK Postal, Japan Postal, Australia Post, Royal Mail 4 State Customer, KIX Code (Dutch), UPU 4 State Postal FICS (Post US4), USPS 4 State Postal (Post US3), Mailmark
Page 48
4 - 8 DS2208 Digital Scanner Product Reference Guide
Table 4-2
Technical Specifications (Continued) Item
Description
Minimum Element Resolution Code 39
4.0 mil
Code 128
4.0 mil
Data Matrix
6.0 mil
QR Code
6.7 mil
Utilities and Management 123Scan
Programs scanner parameters, upgrades firmware, provides scanned bar code data and prints reports (see Chapter 2, 123Scan and Software Tools).
Symbol Scanner SDK
Generates a fully-featured scanner application, including documentation, drivers, test utilities and sample source code (www.zebra.com/ScannerSDKforWindows)
Scanner Management Service (SMS)
Remotely manages your Zebra scanner and queries its asset information (www.zebra.com/sms).
Page 49
Maintenance & Technical Specifications
4-9
Digital Scanner Signal Descriptions
Bottom of scanner
Cable interface port PIN 10
PIN 1
Interface cable modular connector
Figure 4-1
Digital Scanner Cable Pinouts
The signal descriptions in Table 4-3 apply to the connectors on the DS2208 digital scanner and are for reference only. Table 4-3
DS2208 Digital Scanner Signal Pin-outs
Pin
USB
RS-232
Keyboard Wedge
IBM
1
Short to Pin 6
Reserved
1M Resistor to Pin 8
2M Resistor to Pin 8
2
Power
Power
Power
Power
3
Ground
Ground
Ground
Ground
4
Reserved
TXD
KBD_CLK
IBM_TXD
5
D+
RXD
TERM_DATA
IBM_RXD
6
Short to Pin 1
RTS
KBD_DATA
IBM_DIR
7
D-
CTS
TERM_CLK
Reserved
8
Reserved
Reserved
1M Resistor to Pin 1
2M Resistor to Pin 1
9
Reserved
Reserved
Reserved
Reserved
10
Reserved
Reserved
Reserved
Reserved
SHELL
Shield
Shield
Shield
Shield
Page 50