The text of a manual · part 30 of 48
DS2208 Digital Scanner Product Reference Guide: Chapter 12 Symbologies, pages 243 to 252
Pages 243 to 252 of 404, from DS2208 Digital Scanner Product Reference Guide
The original document is the PDF (12 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Zebra DS2208
Page 243
Symbologies
12 - 71
GS1 DataBar Expanded Parameter # 340 SSI # F0h 54h
*Enable GS1 DataBar Expanded (1)
Disable GS1 DataBar Expanded (0)
Convert GS1 DataBar to UPC/EAN/JAN Parameter # 397 SSI # F0h, 8Dh This parameter only applies to GS1 DataBar Omnidirectional and GS1 DataBar Limited symbols not decoded as part of a Composite symbol. Scan Enable Convert GS1 DataBar to UPC/EAN/JAN to strip the leading '010' from DataBar-14 and DataBar Limited symbols encoding a single zero as the first digit, and report the bar code as EAN-13. For bar codes beginning with between two and five zeros, this strips the leading '0100' and reports the bar code as UPC-A. The UPC-A Preamble option that transmits the system character and country code applies to converted bar codes. Note that neither the system character nor the check digit can be stripped.
Enable Convert GS1 DataBar to UPC/EAN/JAN (1)
*Disable Convert GS1 DataBar to UPC/EAN/JAN (0)
Page 244
12 - 72
DS2208 Digital Scanner Product Reference Guide
GS1 DataBar Limited Margin Check Parameter # 728 SSI # F1h D8h The decoder offers four levels of margin check for GS1 DataBar Limited bar codes. There is an inverse relationship between level of margin check and decoder aggressiveness. Increasing the level of margin check may result in reduced aggressiveness in scanning, so only choose the level of margin check necessary. • Level 1: No clear margin required. This complies with the original GS1 standard, yet might result in erroneous decoding of the DataBar Limited bar code when scanning some UPC symbols that start with the digits 9 and 7. • Level 2: Automatic risk detection. This level of security may result in erroneous decoding of DataBar Limited bar codes when scanning some UPC symbols. If a misdecode is detected, the decoder operates in Level 3 or Level 1. • Level 3: Margin check level reflects newly proposed GS1 standard that requires a 5x trailing clear margin. • Level 4: Margin check level extends beyond the standard required by GS1. This level of security requires a 5x leading and trailing clear margin.
GS1 DataBar Limited Margin Check Level 1 (1)
GS1 DataBar Limited Margin Check Level 2 (2)
*GS1 DataBar Limited Margin Check Level 3 (3)
GS1 DataBar Limited Margin Check Level 4 (4)
Page 245
Symbologies
12 - 73
GS1 DataBar Security Level Parameter # 1706 SSI # F8h 06h AAh The decoder offers four levels of decode security for GS1 DataBar (GS1 DataBar 14, GS1 DataBar Limited, GS1 DataBar Expanded) bar codes. • Security Level 0: This setting allows the digital scanner to operate in its most aggressive state, while providing sufficient security in decoding most in-spec bar codes. • Security Level 1: This setting eliminates most misdecodes while maintaining reasonable aggressiveness (default). • Security Level 2: This setting allows greater bar code security requirements if Security Level 1 fails to eliminate misdecodes. • Security Level 3: This setting applies the highest safety requirements. Select if Security Level 2 was applied and misdecodes still occur.
Security Level 0 (0)
* Security Level 1 (1)
Security Level 2 (2)
Security Level 3 (3)
Page 246
12 - 74
DS2208 Digital Scanner Product Reference Guide
Symbology-Specific Security Features Redundancy Level Parameter # 78 SSI # 4Eh The scanner offers four levels of decode redundancy. Select higher redundancy levels for decreasing levels of bar code quality. As redundancy levels increase, the scanner’s aggressiveness decreases. Scan one of the following bar codes to select the redundancy level appropriate for the bar code quality: • Redundancy Level 1 - The scanner must read the following code types twice before decoding: • Codabar (8 characters or less) • MSI (4 characters or less) • D 2 of 5 (8 characters or less) • I 2 of 5 (8 characters or less) • Redundancy Level 2 - The scanner must read all code types twice before decoding. • Redundancy Level 3 - The scanner must read code types other than the following twice before decoding, but must read the following codes three times: • Codabar (8 characters or less) • MSI (4 characters or less) • D 2 of 5 (8 characters or less) • I 2 of 5 (8 characters or less) • Redundancy Level 4 - The scanner must read all code types three times before decoding.
Page 247
Symbologies
Redundancy Level (continued)
*Redundancy Level 1 (1)
Redundancy Level 2 (2)
Redundancy Level 3 (3)
Redundancy Level 4 (4)
12 - 75
Page 248
12 - 76
DS2208 Digital Scanner Product Reference Guide
Security Level Parameter # 77 SSI # 4Dh The scanner offers four levels of decode security for delta bar codes, which include the Code 128 family, UPC/EAN/JAN, and Code 93. Select increasing levels of security for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so choose only that level of security necessary for the application. • Security Level 0 - The scanner operates in its most aggressive state, while providing sufficient security decoding most “in-spec” bar codes. • Security Level 1 - This default setting eliminates most misdecodes. • Security Level 2 - Select this option if Security Level 1 fails to eliminate misdecodes. • Security Level 3 - If you selected Security Level 2 and misdecodes still occur, select this security level. NOTE Selecting this option is an extreme measure against mis-decoding severely out-of-spec bar codes, and significantly impairs the decoding ability of the scanner. If this level of security is required, try to improve the quality of the bar codes.
Security Level 0 (0)
*Security Level 1 (1)
Security Level 2 (2)
Security Level 3 (3)
Page 249
Symbologies
12 - 77
1D Quiet Zone Level Parameter # 1288 SSI # F8h 05h 08h This feature sets the level of aggressiveness when decoding bar codes with a reduced quiet zone (the margin on either side of a bar code), and applies to symbologies enabled by a Reduced Quiet Zone parameter. Because higher levels increase the decoding time and risk of misdecodes, Zebra strongly recommends enabling only the symbologies which require higher quiet zone levels, and leaving Reduced Quiet Zone disabled for all other symbologies. Options are: • 1D Quiet Zone Level 0 - The scanner performs normally in terms of quiet zone. • 1D Quiet Zone Level 1 - The scanner performs more aggressively in terms of quiet zone. • 1D Quiet Zone Level 2 - The scanner only requires a quiet zone at the end of bar code for decoding. • 1D Quiet Zone Level 3 - The scanner decodes anything in terms of quiet zone or end of bar code.
1D Quiet Zone Level 0 (0)
*1D Quiet Zone Level 1 (1)
1D Quiet Zone Level 2 (2)
1D Quiet Zone Level 3 (3)
Page 250
12 - 78
DS2208 Digital Scanner Product Reference Guide
Intercharacter Gap Size Parameter # 381 SSI # F0h, 7Dh The Code 39 and Codabar symbologies have an intercharacter gap that is typically quite small. Due to various bar code printing technologies, this gap can grow larger than the maximum size allowed, preventing the scanner from decoding the symbol. If this problem occurs, scan the Large Intercharacter Gaps parameter to tolerate these out-of-specification bar codes.
*Normal Intercharacter Gaps (6)
Large Intercharacter Gaps (10)
Composite Composite CC-C Parameter # 341 SSI # F0h 55h Scan one of the following bar codes to enable or disable Composite bar codes of type CC-C.
Enable CC-C (1)
*Disable CC-C (0)
Page 251
Symbologies
Composite CC-A/B Parameter # 342 SSI # F0h 56h Scan one of the following bar codes to enable or disable Composite bar codes of type CC-A/B.
Enable CC-A/B (1)
*Disable CC-A/B (0)
Composite TLC-39 Parameter # 371 SSI # F0h 73h Scan one of the following bar codes to enable or disable Composite bar codes of type TLC-39.
Enable TLC39 (1)
*Disable TLC39 (0)
12 - 79
Page 252
12 - 80
DS2208 Digital Scanner Product Reference Guide
Composite Inverse Parameter # 1113 SSI # F8h 04h 59h This parameter sets Composite for either regular decode or inverse decode. This mode only supports Inverse Composite that has DataBar combined with CCAB. No other 1D/2D combinations. • Regular Only: The digital scanner decodes regular Composite bar codes only. (default). • Inverse Only: The digital scanner decodes inverse Composite bar codes only. For this parameter to work as expected, Composite CC-A/B on page 12-79 and corresponding 1D Inverse or 1D Inverse Autodetect (page 12-69) must be enabled. NOTE To decode regular Composite, Composite Inverse must be set to Regular Only and Inverse 1D must be set to Regular Only or Autodetect.
To decode inverse Composite, Composite Inverse must be set to Inverse Only and Inverse 1D must be set to Inverse Only or Autodetect.
* Regular Only (0)
Inverse Only (1)