Code 128 <FNC4> Parameter # 1254 SSI # F8h 04h E6h This feature applies to Code 128 bar codes with an embedded <FNC4> character. Select Ignore Code 128 <FNC4> to strip the <FNC4> character from the decode data. The remaining characters are sent to the host unchanged. When disabled, the <FNC4> character is processed normally as per Code 128 standard.
*Honor Code 128 <FNC4> (0)
Ignore Code 128 <FNC4> (1)
Code 128 Security Level Parameter # 751 SSI # F1h EFh Code 128 bar codes are vulnerable to misdecodes, particularly when Code 128 Lengths is set to Any Length. The scanner offers four levels of decode security for Code 128 bar codes. There is an inverse relationship between security and scanner aggressiveness. Increasing the level of security can reduce scanning aggressiveness, so select only the level of security necessary. • Code 128 Security Level 0 - The scanner operates in its most aggressive state, while providing sufficient security in decoding most in-spec bar codes. • Code 128 Security Level 1 - This option eliminates most misdecodes while maintaining reasonable aggressiveness. • Code 128 Security Level 2 - This option applies greater bar code security requirements if Security Level 1 fails to eliminate misdecodes. • Code 128 Security Level 3 - If you selected Security Level 2, and misdecodes still occur, select this security level to apply the highest safety requirements. NOTE Selecting this option is an extreme measure against mis-decoding severely out-of-spec bar codes, and significantly impairs the decoding ability of the scanner. If this level of security is required, try to improve the quality of the bar codes.
Page 204
12 - 32
DS2208 Digital Scanner Product Reference Guide
Code 128 Security Level (continued)
Code 128Security Level 0 (0)
*Code 128 Security Level 1 (1)
Code 128 Security Level 2 (2)
Code 128 Security Level 3 (3)
Code 128 Reduced Quiet Zone Parameter # 1208 SSI # F8h 04h B8h Scan one of the following bar codes to enable or disable decoding Code 128 bar codes with reduced quiet zones (the margins on either side of the bar code). If you select Enable, select a 1D Quiet Zone Level on page 12-77.
Enable Code 128 Reduced Quiet Zone (1)
*Disable Code 128 Reduced Quiet Zone (0)
Page 205
Symbologies
12 - 33
Code 39 Parameter # 0 SSI # 00h Scan one of the following bar codes to enable or disable Code 39.
*Enable Code 39 (1)
Disable Code 39 (0)
Trioptic Code 39 Parameter # 13 SSI # 0Dh Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges. Trioptic Code 39 symbols always contain six characters. Scan one of the following bar codes to enable or disable Trioptic Code 39.
Enable Trioptic Code 39 (1)
*Disable Trioptic Code 39 (0) NOTE You cannot enable Trioptic Code 39 and Code 39 Full ASCII simultaneously.
Page 206
12 - 34
DS2208 Digital Scanner Product Reference Guide
Convert Code 39 to Code 32 Parameter # 86 SSI # 56h Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan one of the following bar codes to enable or disable converting Code 39 to Code 32. NOTE Code 39 must be enabled for this parameter to function.
Enable Convert Code 39 to Code 32 (1)
*Disable Convert Code 39 to Code 32 (0)
Code 32 Prefix Parameter # 231 SSI # E7h Scan one of the following bar codes to enable or disable adding the prefix character “A” to all Code 32 bar codes. NOTE Convert Code 39 to Code 32 must be enabled for this parameter to function.
Enable Code 32 Prefix (1)
*Disable Code 32 Prefix (0)
Page 207
Symbologies
12 - 35
Set Lengths for Code 39 L1 = Parameter # 18 SSI # 12h L2 = Parameter # 19 SSI # 13h NOTE The maximum number of 1D bar code characters readable with scanner depends on the type of symbology, type of characters (i.e., digits or letters), printing density, and quality. For reference, the DS2208 reads 3.1 in wide, 10mil 1D bar codes printed with 1200dpi resolution and 80% contrast.
The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 39 to any length, one or two discrete lengths, or lengths within a specific range. If Code 39 Full ASCII is enabled, Length Within Range or Any Length are the preferred options. Minimum and maximum length range is from 0 - 80. The default minimum and maximum length range is from 1 - 55. NOTE When setting lengths, enter a leading zero for single digit numbers.
Scan one of the following bar codes to select a length option: • One Discrete Length - Decode only Code 39 symbols containing a selected length. Select the length using the bar codes in Appendix G, Numeric Bar Codes. For example, to decode only Code 39 symbols with 14 characters, scan Code 39 - One Discrete Length, and then scan 1, 4. To correct an error or change the selection, scan Cancel on page G-3. • Two Discrete Lengths - Decode only Code 39 symbols containing either of two lengths. Select lengths using the bar codes in Appendix G, Numeric Bar Codes. For example, to decode only Code 39 symbols containing either 2 or 14 characters, scan Code 39 - Two Discrete Lengths, and then scan 0, 2, 1, 4. To correct an error or change the selection, scan Cancel on page G-3. • Length Within Range - Decode Code 39 symbols with a specific length range. Select lengths using the bar codes in Appendix G, Numeric Bar Codes. For example, to decode Code 39 symbols containing between 4 and 12 characters, scan Code 39 - Length Within Range, and then scan 0, 4, 1, 2. To correct an error or change the selection, scan Cancel on page G-3. • Any Length - Decode Code 39 symbols containing any number of characters within the scanner’s capability.
Page 208
12 - 36
DS2208 Digital Scanner Product Reference Guide
Set Lengths for Code 39 (continued)
Code 39 - One Discrete Length
Code 39 - Two Discrete Lengths
*Code 39 - Length Within Range (Default: 1 - 55)
Code 39 - Any Length
Code 39 Check Digit Verification Parameter # 48 SSI # 30h Scan Enable Code 39 Check Digit to check the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm. Only Code 39 symbols which include a modulo 43 check digit are decoded. Enable this feature if the Code 39 symbols contain a Modulo 43 check digit.
Enable Code 39 Check Digit (1)
*Disable Code 39 Check Digit (0)
Page 209
Symbologies
12 - 37
Transmit Code 39 Check Digit Parameter # 43 SSI # 2Bh Scan one of the following bar codes to transmit Code 39 data with or without the check digit.
Transmit Code 39 Check Digit (Enable) (1)
*Do Not Transmit Code 39 Check Digit (Disable) (0) NOTE Code 39 Check Digit Verification must be enabled for this parameter to function.
Code 39 Full ASCII Conversion Parameter # 17 SSI # 11h Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. Scan one of the following bar codes to enable or disable Code 39 Full ASCII.
Enable Code 39 Full ASCII (1)
*Disable Code 39 Full ASCII (0) NOTE You cannot enable Trioptic Code 39 and Code 39 Full ASCII simultaneously.
Code 39 Full ASCII to Full ASCII Correlation is host-dependent, and is therefore described in the ASCII character set table for the appropriate interface. See Table I-1 on page I-1.
Page 210
12 - 38
DS2208 Digital Scanner Product Reference Guide
Code 39 Security Level Parameter # 750 SSI # F1h EEh The scanner offers four levels of decode security for Code 39 bar codes. There is an inverse relationship between security and scanner aggressiveness. Increasing the level of security can reduce scanning aggressiveness, so select only the level of security necessary. • Code 39 Security Level 0: The scanner operates in its most aggressive state, while providing sufficient security in decoding most in-spec bar codes. • Code 39 Security Level 1: This default setting eliminates most misdecodes. • Code 39 Security Level 2: This option applies greater bar code security requirements if Security Level 1 fails to eliminate misdecodes. • Code 39 Level 3: If you selected Security Level 2, and misdecodes still occur, select this security level to apply the highest safety requirements. NOTE Selecting this option is an extreme measure against mis-decoding severely out-of-spec bar codes, and significantly impairs the decoding ability of the scanner. If this level of security is required, try to improve the quality of the bar codes.
Page 211
Symbologies
Code 39 Security Level (continued)
Code 39 Security Level 0 (0)
*Code 39 Security Level 1 (1)
Code 39 Security Level 2 (2)
Code 39 Security Level 3 (3)
12 - 39
Page 212
12 - 40
DS2208 Digital Scanner Product Reference Guide
Code 39 Reduced Quiet Zone Parameter # 1209 SSI # F8h 04h B9h Scan one of the following bar codes to enable or disable decoding Code 39 bar codes with reduced quiet zones (the margins on either side of the bar code). If you select Enable, select a 1D Quiet Zone Level on page 12-77.
Enable Code 39 Reduced Quiet Zone (1)
*Disable Code 39 Reduced Quiet Zone (0)
Code 93 Parameter # 9 SSI # 09h Scan one of the following bar codes to enable or disable Code 93.
*Enable Code 93 (1)