For the Zebex ZB-800

Page 1

ZBX98070101 P/N : MUL-53215-01

Page 2

IMPORTANT NOTICE

USER'S MANUAL

ZB- 800 SERIES

ZEBEX INDUSTRIES INC. MAKES NO WARRANTY WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. ZEBEX INDUSTRIES INC. SHALL NOT BE LIABLE FOR ERRORS CONTAINED HEREIN OR FOR INCIDENTAL CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIALS. Copyright 1995 by ZEBEX INDUSTRIES INC. IBM is a registered trade mark of International Business Machines Corp. IBM PC/XT is a product of International Business Machines Corp. IBM PC/AT is a product of International Business Machines Corp. IBM PS/2 is a product of International Business Machines Corp. NEC is a registered trade mark of NEC Corporation. All other registered trade marks are registered companys' property. ZEBEX is a registered trade mark of ZEBEX INDUSTRIES INC.

All rights reserved, reproduction of this document or any portion of its contents is not allowed without the specific written consent of ZEBEX INDUSTRIES INC.

The manual can be used as keyboard emulation, RS- 232C serial interface, and CMOS serial interface.

Every effort is made to ensure the accuracy of our product information; however, we accept no responsibility for errors or omission. Specification or version may be subject to change without notice. The actual specification and version are based on the product delivered.

PRINTED IN DECEMBER 1995

Page 3

IMPORTANT NOTICE

USER'S MANUAL Every effort is made to ensure the accuracy of our product information; however, we accept no responsibility for errors or omission. Specification or version may be subject to change without notice. The actual specification and version are based on the product delivered.

The manual can be used as keyboard emulation, RS- 232C serial interface, and CMOS serial interface.

PRINTED IN DECEMBER 1995

Page 4

TABLE OF CONTENTS Introduction ....................................................1 Default Parameters.........................................2 Program Procedure ........................................5 System Setting ...............................................6 Header And Trailer .........................................7 Inter- Message Delay......................................7 Inter- Character Delay ....................................7 Message/ Block Mode Selection .....................8 Beeper Tone Selection ...................................8 Bar Code ID Selection ....................................9 RS- 232C Serial Communication Parameters Setting .......................................................10 Handshaking Protocol...........................10 ACK/ NAK Response Time Setting........10 Baud Rate............................................11 Data Bit................................................11 Stop Bit ................................................12 Parity Setting........................................12 Message Terminator.............................12 Keyboard Emulation Parameters Setting .......13 Keyboard Type Selection......................13 Language Selection..............................14 Message Terminator.............................15 Reading Code Selection ...............................15 Code 39 Parametrs Setting...........................17 Interleaved 2 Of 5 Parameters Setting...........18 SLZ 2 Of 5 Parameters Setting .....................18 UPC/ EAN/ JAN Parameters Setting .............19 Codabar/ Monarch Parameters Setting..........22 Code 128 Parameters Setting .......................23 ISBN/ ISSN Conversion ................................23 Appendix A Code 39 Full ASCII Code Table ....................24 Appendix B Code 39 Full ASCII Bar Code TAble..............26

Page 5

1. INTRODUCTION The series Bar Code Wand scanners can be configured by scanning a series of programming bar code labels. This allows decoding options and interface protocols to be tailored to a specific application. The configuration is stored in nonvolatile memory and will not be lost by removing power from the scanner. The scanner must be properly powered before programming. For RS-232C type scanners, an external power adaptor must be used to supply DC power to the scanner. If a keyboard emulation type scanner is used with a IBM PC/XT/AT, PS/2 or any fully compatible computers, power will be drawn from the keyboard port. No external power adaptor is required. If keyboard emulation type scanner is used with any other non IBM PC compatible computers, an external power adaptor may be needed. During the programming mode, the scanner will acknowledge a good and valid reading with a short beep. It will give long beeps for either an invalid or bad reading. 2. PROGRAMMING OPTIONS Programmable options are divided into four groups. The first group includes the options that show the general behavior of the scanner. The second group of options governs the operation of RS-232C type serial ports. The third group selects the keyboard type that the keyboard emulation type will be emulated. The last group sets the decoding parameters for each bar code symbology.

1

Page 6

3. DEFAULT PARAMETERS

DEFAULT VALUES OF KEYBOARD EMULATION PARAMETERS SETTING

This table gives the default settings of all the programmable parameters. The default settings will be restored whenever the "Reset" programming label is scanned and the scanner is in programming mode. DEFAULT VALUES OF OPERATING PARAMETERS Function Header and trailer Inter-Message delay Inter-Character delay Message/Block mode selection Send command in block mode communication Good read beeper tone selection Code identifier transmmiting Code 39 bar code identifier code ITF 2 of 5 bar code identifier code SLZ 2 of 5 bar code identifier code UPC-E bar code identifier code UPC-A bar code identifier code EAN-13 bar code identifier code EAN-8 bar code identifier code Codabar bar code identifier code Code 128 bar code identifier code Code 93 bar code identifier code MSI bar code identifier code

2

Default Values None Normal Normal Message Disable 2KHz/120 mSec Disable M I H E E F FF N K L P

Function Keyboard type selection Message terminator

Default Values IBM PC/AT USA Enter/ Carriage Return

DEFAULT VALUES OF RS-232C SERIAL COMMUNICATION PARAMETERS

Function Handshaking protocol ACK/NAK response time setting Baud rate Data bit Stop bit Parity Message terminator selection

3

Default Values None 300 msec 9600 8 1 Mark (None) CR/LF

Page 7

DEFAULT VALUES OF DECODING PARAMETERS Function Code 39 ITF 2 of 5 SLZ 2 of 5 UPC/EAN/JAN Codabar Reading Codes ¡ ° MSI Selection Code 128 Code 93 ¡° ITAT

¡ °Italian Pharmac

4. PROGRAM PROCEDURE USING BAR CODE MENUS

Default Value Enable Enable Disable Enable Enable Disable

START

Enable Enable Disable

Read Start of Configuration Label

Disable

ISSN/ ISBN Disable Codes Standard Code 39 Start/stop characters Not transmitting Check digit Disable Interleaved Length 10 digits Fixed 2 of 5 Check Digit Disable SLZ 2 of 5 Length Variable Check Digit Disable Format All Addendum Disable UPC-E=UPC-A Disable UPC-A= EAN-13 Disable UPC/EAN/JAN UPC-A Leading Digit Transmit UPC-A Check Digit Transmit UPC-E Leading Digit Transmit UPC-E Check Digit Transmit EAN-13 Check Digit Transmit EAN-8 Check Digit Transmit Type Standard Codabar Start/ Stop A,B,C,D Characters Code 128 FNC 2 Append Disable Check Digit Calculate but not Transmit MSI Length Variable Check digit Transmit Italian Pharmac Transmit "A" Not transmitting Character

Note: The configuration of the items with asterisk (¡ ° ) is optional.

Set All Defaults

Set Operating Parameters

Set Serial Port Parameters

No

Set Set Keyboard Decoding Type Parameters

No Finish

Discard

Yes

Yes

Read End of configuration label

Read Abort Label

END

5

Page 8

HEADER AND TRAILER Start of Configuration • The reading of the "RESET " label turns all the parameters back to default values. • When you intend to turn your scanner back to default parameter, please scan the "Start of configuration" label first, then scan "RESET" label and finally scan the "End of configuration" label.

•

RESET The reading of the "ABORT" label discards all the parameters read prior to the "End of configuration".

Header Trailer Set INTER-MESSAGE DELAY

None

100 mSec 500 mSec

•

ABORT The lable below must be read to enter into serial interface for ZB- 800R or ZB- 800C when the wand is configured the first time.

1 Second INTER-CHARACTER DELAY

None

•

RS-232C The lable below must be read to enter into serial interface for ZB- 800K when the wand is configured the first time.

10 mSec 20 mSec 50 mSec

PC/ AT 6

End of Configuration 7