Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 10

ZB-8150/ZB-8110/ZB-8210 CCD Barcode Scanner User's Manual, pages 61 to 70

Pages 61 to 70 of 95

The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the ZBA Inc ZB-8110 and ZBA Inc ZB-8150

Page 61

MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable)

(Optional)

(Optional)

Checksum Verification: The MSI/Plessey has one or two optional checksum digits.

The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10.

The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.

Program Option Bar Code

Option

Alphanumeric Entry

Disable

00*

Enable

01

Disable

00*(8110)

Mod 10

01*(8150/8210)

Checksum

Mod 10/10

02

Verification

Mod 11/10

03

Read

61

Page 62

Disable

00*

Enable

01

00-64

00-64

Checksum Transmission

00* Max. code length 00-64

00-64 00*

Min. code length 0-15

00-15 00*

Truncate leading 0-15

00-15 00*

Truncate ending 00-ffH ASCII

00-ffH code

< @ >*

00-44

00-44

Code ID setting

00* Insert group selection

Exit

62

Page 63

UK/plessey Read: Format Data Digits

Checksum1+2

(Variable)

(Optional)

Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.

Program Option Bar Code

Option

Alphanumeric Entry

Disable

00*

Enable

01

Disable

00

Enable

01*

Read

Checksum Verification

63

Page 64

Disable

00*

Enable

01

00-64

00-64

Checksum Transmission

00* Max. code length 00-64

00-64 00*

Min. code length 0-15

00-15 00*

Truncate leading 0-15

00-15 00*

Truncate ending 00-ffH ASCII

00-ffH code

< @ >*

00-44

00-44

Code ID setting

00* Insert group selection

Exit

64

Page 65

Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.

Program Option Bar Code

Option

Alphanumeric Entry

Disable

00*

Enable

01

Disable

00*

Enable

01

Disable

00*

Enable

01

Read

Checksum Verification

Checksum Transmission

65

Page 66

00-64

00-64 00*

Max. code length 00-64

00-64 00*

Min. code length 0-15

00-15 00*

Truncate leading 0-15

00-15 00*

Truncate ending 00-ffH ASCII

00-ffH code

< S >*

00-44

00-44

Code ID setting

00* Insert group selection Numeric only

00*

Full ASCII only

01

Format

Exit

66

Page 67

Standard 2 of 5 Read: Format Data Digits

Checksum1

(Variable)

(Optional)

Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.

Program Option Bar Code

Option

Alphanumeric Entry

Disable

00*

Enable

01

00-64

00-64

Read

00* Max. code length 00-64

00-64 00*

Min. code length

67

Page 68

0-15

00-15 00*

Truncate leading 0-15

00-15 00*

Truncate ending 00-ffH ASCII

00-ffH code

< i >*

00-44

00-44

Code ID setting

00* Insert group selection

Exit

68

Page 69

RSS-14 Read: Format Data Digits

Checksum1

(Variable)

(Optional)

Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. UCC/EAN 128 emulation: Refer to Transmission (P89), Code ID transmission must be set as AIM ID enable. Then ]C1 will be identified as prefix of barcode data transmission.

Program Option Bar Code

Option

Alphanumeric Entry

Disable

00*

Enable

01

00-64

00-64

Read

64* Max. code length 00-64

00-64 01*

Min. code length

69

Page 70

0-15

00-15 00*

Truncate leading 0-15

00-15 00*

Truncate ending 00-ffH ASCII

00-ffH code

< R4 >*

00-44

00-44

Code ID setting

00* Insert group selection Disable

00*

Enable

01

UCC/EAN128 emulation

Exit

70