The text of a manual · part 7 of 10
ZB-8150/ZB-8110/ZB-8210 CCD Barcode Scanner User's Manual, pages 61 to 70
Pages 61 to 70 of 95
The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the ZBA Inc ZB-8110 and ZBA Inc ZB-8150
Page 61
MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable)
(Optional)
(Optional)
Checksum Verification: The MSI/Plessey has one or two optional checksum digits.
The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10.
The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00*
Enable
01
Disable
00*(8110)
Mod 10
01*(8150/8210)
Checksum
Mod 10/10
02
Verification
Mod 11/10
03
Read
61
Page 62
Disable
00*
Enable
01
00-64
00-64
Checksum Transmission
00* Max. code length 00-64
00-64 00*
Min. code length 0-15
00-15 00*
Truncate leading 0-15
00-15 00*
Truncate ending 00-ffH ASCII
00-ffH code
< @ >*
00-44
00-44
Code ID setting
00* Insert group selection
Exit
62
Page 63
UK/plessey Read: Format Data Digits
Checksum1+2
(Variable)
(Optional)
Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00*
Enable
01
Disable
00
Enable
01*
Read
Checksum Verification
63
Page 64
Disable
00*
Enable
01
00-64
00-64
Checksum Transmission
00* Max. code length 00-64
00-64 00*
Min. code length 0-15
00-15 00*
Truncate leading 0-15
00-15 00*
Truncate ending 00-ffH ASCII
00-ffH code
< @ >*
00-44
00-44
Code ID setting
00* Insert group selection
Exit
64
Page 65
Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00*
Enable
01
Disable
00*
Enable
01
Disable
00*
Enable
01
Read
Checksum Verification
Checksum Transmission
65
Page 66
00-64
00-64 00*
Max. code length 00-64
00-64 00*
Min. code length 0-15
00-15 00*
Truncate leading 0-15
00-15 00*
Truncate ending 00-ffH ASCII
00-ffH code
< S >*
00-44
00-44
Code ID setting
00* Insert group selection Numeric only
00*
Full ASCII only
01
Format
Exit
66
Page 67
Standard 2 of 5 Read: Format Data Digits
Checksum1
(Variable)
(Optional)
Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00*
Enable
01
00-64
00-64
Read
00* Max. code length 00-64
00-64 00*
Min. code length
67
Page 68
0-15
00-15 00*
Truncate leading 0-15
00-15 00*
Truncate ending 00-ffH ASCII
00-ffH code
< i >*
00-44
00-44
Code ID setting
00* Insert group selection
Exit
68
Page 69
RSS-14 Read: Format Data Digits
Checksum1
(Variable)
(Optional)
Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. UCC/EAN 128 emulation: Refer to Transmission (P89), Code ID transmission must be set as AIM ID enable. Then ]C1 will be identified as prefix of barcode data transmission.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00*
Enable
01
00-64
00-64
Read
64* Max. code length 00-64
00-64 01*
Min. code length
69
Page 70
0-15
00-15 00*
Truncate leading 0-15
00-15 00*
Truncate ending 00-ffH ASCII
00-ffH code
< R4 >*
00-44
00-44
Code ID setting
00* Insert group selection Disable
00*
Enable
01
UCC/EAN128 emulation
Exit
70