The text of a manual · part 5 of 10
ZB-8150/ZB-8110/ZB-8210 CCD Barcode Scanner User's Manual, pages 41 to 50
Pages 41 to 50 of 95
The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the ZBA Inc ZB-8110 and ZBA Inc ZB-8150
Page 41
Code 39 Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect. The length is defined as to the actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure that the Minimum length setting is no greater than the Maximum length setting, or otherwise all the labels of the symboblogy will not be readable. In particular, you can see the same value for both Minimum and Maximum reading length to force the fixed length barcode decoded. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z).
Program Option Bar Code
Option
Alphanumeric Entry
41
Page 42
00-64
00-64 00*
Max. code length 00-64
00-64 00*
Min. code length 0-15
00-15 00*
Truncate leading 0-15
00-15 00*
Truncate ending 00-ffH ASCII
00-ffH code
<*>
00-44
00-44
Code ID setting
00* Insert group selection Standard
00*
Full ASCII
01
Format
Exit
42
Page 43
Code 39 Append: This function allows several symbols to be concatenates and be treat as one single data entry. The scanner will not transmit the embedded appending code (space for Code-39). If Enable and other symbols were read again with the appended code, then codes will be transmitted without Code ID, Preamble and Prefix. When a symbol was decoded without the appended code, the data will be transmitted without Code ID and Prefix, but the Postamble Suffix codes are appended. This function is used when the first number of code 39 is a space. Example: □123456. Start/end transmission: The start and end characters of Code-39 are“★”. You can transmit all data digits including two “★”.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00*
Enable
01
Disable
00*
Enable
01
Append
Start/end transmission
Exit
43
Page 44
Interleaved 2 of 5 Read: Format Data Digits
Checksum
(Variable)
(Optional)
Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum and will be transmitted.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00
Enable
01*
Disable
00
Enable
01*
Disable
00*
Enable
01
Read
Check-sum verification
Check-sum transmission
Exit
44
Page 45
Interleaved 2 of 5 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
00-64
00-64 00*
Max. code leading 00-64
00-64 00*
Min. code leading 0-15
00-15 00*
Truncate leading 0-15
00-15 00*
Truncate ending
45
Page 46
00-ffH ASCII
00-ffH code
< i >*
00-44
00-44
Code ID setting
00* Insert group selection
Exit
46
Page 47
Industrial 2 of 5 Read: Format Data Digits
Checksum
(Variable)
(Optional)
Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00*
Enable
01
00-64
00-64
Read
00* Max. code length 00-64
00-64 00*
Min. code length
47
Page 48
0-15
00-15 00*
Truncate leading 0-15
00-15 00*
Truncate ending 00-ffH ASCII
00-ffH code
< i >*
00-44
00-44
Code ID setting
00* Insert group selection
Exit
48
Page 49
Matrix 2 of 5 Eur Read: Format Data Digits
Checksum
(Variable)
(Optional)
Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum and will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00*
Enable
01
Disable
00*
Enable
01
Read
Checksum Verification
49
Page 50
Disable
00*
Enable
01
00-64
00-64
Checksum Transmission
00* Max. code length 00-64
00-64 00*
Min. code length 0-15
00-15 00*
Truncate leading 0-15
00-15 00*
Truncate ending 00-ffH ASCII
00-ffH code
< B >*
00-44
00- 44
Code ID setting
00* Insert group selection
Exit
50