Page 101

Getting Started with MAXserver Access Servers

Enabling/Disabling Status Message Display To enable or disable loading status messages, complete the following steps: 1. Type M at the Enter Menu Selection prompt on the Access server Configuration menu and press RETURN. The unit prompts: DISPLAY LOAD STATUS MESSAGES (Y,N) [Y]: 2. To disable load status messages, enter ‘N’. Otherwise, leave the default (Y) intact. NOTE: You might want to prevent the unit from generating status messages during the software loading process, if a device such as a bar code reader, which cannot interpret status messages, is connected to a serial port. Memory Configuration To configure the amount of memory in the MAXserver, complete the following steps after enabling/disabling load status messages. The configuration menu prompts: TOTAL INSTALLED MEMORY IN MEGABYTES (4,6,8) [4]: The prompt indicates the amount of installed memory for which the unit has been configured. If you remove memory, you must change this value. (Preferably, you should change this value before you remove the memory.) Also, if you have enabled more software features than the unit can support with the reduced memory, you will not be able to re-initialize the unit after you remove the SIMMs. If this happens, you must re-install the SIMMs and configure the TCP/IP-LAT software image for fewer features. SIMMs should only be installed or removed by qualified personnel. See the 0038

101

Page 102

Getting Started with MAXserver Access Servers instructions later in this guide to install and remove SIMM modules. The unit automatically detects added memory. Therefore, you do not need to increase the "installed memory" value when you install additional memory. If you want to increase the value, install the additional memory first. If you do, the unit will generate the following warning message: WARNING: AFTER SAVING THE NEW CONFIGURATION, YOU MUST TURN THE UNIT OFF AND INSTALL THE ADDITIONAL MEMORY SPECIFIED (X MB). (TYPE ANY KEY TO CONTINUE) NOTE:

This message displays only while you are using the Configuration menu.

Also, the MAXserver front panel lights will flash an error code the next time the unit is initialized, if you have not yet installed the memory. 2. Press any key. The unit returns you to the Modify Unit Configuration Menu.

Resetting the Unit’s Load and Dump Protocols to Factory Defaults The “Set Unit Configuration to Defaults” menu option lets you reinitialize all of the unit’s initialization records to the factory default settings. See Table 5 for the factory default settings. NOTE:

102

This option will not reset the server and port parameters to default values. (See “Initializing Server and Port Parameters” for information on resetting the the server and port parameters to default values.)

0038

Page 103

Getting Started with MAXserver Access Servers

To choose this option, complete the following steps: 1. Enter ROM configuration mode. At the # prompt, enter the word access. The Terminal Server Configuration Menu is displayed. 2. Choose Option 2 (“Modify Unit Configuration”) from the Terminal Server Configuration Menu. 3. Type D at the Enter menu selection prompt on the Modify Unit Configuration Menu and press RETURN. The unit displays the following prompt: INITIALIZE ALL CONFIGURATION DATA FOR THIS UNIT TO DEFAULTS (Y,N) [N]? ‘Y’ -- All initialization records and miscellaneous settings (including status messages enabled and installed memory of 4MB) will be returned to their factory default settings. If the factory default settings have not been changed, the following message displays: CONFIGURATION IS ALREADY SET TO DEFAULTS ‘ N’ -- The settings will not be returned to their factory default settings. 4. After you have answered Y or N, the unit prompts: (Type any key to continue) 5. Press any key to return to the Modify Unit Configuration Menu.

0038

103

Page 104

Getting Started with MAXserver Access Servers

Initializing Server and Port Parameters The Initialize Server and Port Parameters option instructs the operating software, once loaded, to use factory default values for all server and port parameters. All current server and port parameters will be lost when you exit from the menu (using Option S "Exit saving configuration changes"). 1. To select this option, type 3 at the "Enter menu selection" prompt of the Access Server Configuration Menu (Figure C-1). The server prompts: WHEN THE SOFTWARE HAS BEEN LOADED, SHOULD DEFAULT SERVER AND PORT PARAMETERS BE USED (Y,N) [N]? 2. Type Y to use the defaults or N to keep the configuration you created, then press RETURN. The unit returns you to the Configuration menu. The parameter initialization takes effect after you exit from the Configuration menu and the unit loads its image. Changes you have made through the Access Server Configuration menu take place only after you exit from the menu, having chosen Option S (“exit saving configuration changes”).

Revert to Stored Configuration The Revert to Stored Configuration option lets you cancel any changes you have made without exiting from the menu. The unit reverts to the configuration values that were last saved. Typically, you would select this option if you had changed some settings, and then decided to undo the changes and begin again. 1. To select this option, type 4 at the "Enter menu selection" prompt of the Access server Configuration Menu (Figure 28). The configuration menu prompts: REVERT TO THE STORED CONFIGURATION (Y,N) [N]? Y

104

0038

Page 105

Getting Started with MAXserver Access Servers

2. Type N and press RETURN to return to the Configuration menu, or type Y and press RETURN. The unit displays the following message: CONFIGURATION RESET TO STORED VALUES. (TYPE ANY KEY TO CONTINUE) 3. Press any key. The unit returns you to the Access server Configuration menu (Figure 28). You can then exit from the Configuration menu using Option S or X.

Exit Saving Configuration Changes The Exit Saving Configuration Changes option lets you exit from the Configuration menu and store the changes that you have made. To select this option, complete the following steps: 1. Type S at the "Enter menu selection" prompt of the Access server Configuration Menu (Figure 28). If you have made any changes, the configuration menu prompts: SAVE CHANGES AND EXIT (Y,N) [Y]? If the unit is configured to store parameters locally, you see this message: UPDATING CONFIGURATION DATA;

PLEASE WAIT...

If you have not made any changes, the following message displays: NO CHANGES MADE.

EXIT CONFIGURATION MENU (Y,N) [Y]?

2. To exit from the Configuration menu, press RETURN. If you do not want to exit from the menu, type 'N' and press RETURN. The Configuration menu appears.

Exit Without Saving Configuration Changes 0038

105

Page 106

Getting Started with MAXserver Access Servers

The Exit Without Saving Configuration Changes option on the Configuration menu lets you exit without saving the configuration changes that you have made (i.e., use the configuration that was last saved). 1. To select this option, type X at the "Enter menu selection" prompt. If you have made changes, the configuration menu prompts: Exit without saving changes (Y/N) [N]? 2. To exit the Configuration menu, type Y and press RETURN. If youdo not want to exit from the menu, type N and press RETURN to redisplay the Configuration menu. If you have not made any changes, the configuration menu displays: NO CHANGES MADE. EXIT CONFIGURATION MENU (Y,N) [Y]?

106

0038

Page 107

Getting Started with MAXserver Access Servers

Command Line Interface This section describes the commands you can use to configure the MAXserver from the command line:

·

Viewing Initialization Parameters

·

Changing the name of the software image file

·

Assigning IP addresses to the network host, access server, gateway, and the network host where the image file resides

·

Changing the Status of an Initialization Record

·

Enabling and Disabling Protocols

·

Resetting Parameters in Initialization Records to Default Values

See the Commands Reference Guide for a complete listing of all commands.

Displaying an Initialization Record Use the following command to display an initialization record: LIST SERVER LOADDUMP [primary] CHARACTERISTICS [secondary] [tertiary]

0038

107

Page 108

Getting Started with MAXserver Access Servers

Figure 33 shows a sample display. Primary Record: Enabled Internet Load Address 0.0.0.0 Internet Load Host 0.0.0.0 Internet Load Gateway 0.0.0.0 Internet Load File None Software: XPCSRV20 Image Load Protocols Enabled: Card, XMOP, MOP, BOOTP, RARP Dump Protocols Enabled: XMOP, MOP, BOOTP, RARP Parameter Protocols Enabled: NVS, XMOP, MOP, BOOTP, RARP

Figure 33 - Sample Primary Initialization Record Display

108

Field

Means

Primary Record

The status of the initialization record. This example shows the primary record enabled, but an initialization record can be enabled or disabled.

Internet Load Address

The IP address of the host where the access server receives its software load image through DTFTP.

Internet Load Gateway

The IP address of a gateway, if the access server requires a gateway to reach the Internet load host through DTFTP.

Internet Load File

The name and path of the software load image on the Internet host, that the access server loads through DTFTP.

Software

The CARD/XMOP/MOP software load image file name.

Image Load Protocols Enabled

The protocols that the initialization record can use to obtain the software load image.

Dump Protocols Enabled

The protocols that the initialization record can use to transmit a memory dump file.

Parameter Protocols Enabled

The protocols that the initialization record can use to obtain the parameter file.

0038

Page 109

Getting Started with MAXserver Access Servers

Enabling/Disabling Image and Parameter Protocols Use the following command to enable or disable software load image protocols and operational parameter protocols: Use this command to specify one or all load protocols to use when the access server searches for a software load image file or a parameter file. You specify whether the protocol applies to the software load image or the parameter file in the command line. By default, a MAXserver attempts to obtain the software load image using the CARD protocol and the parameter file using the NVS protocol. If a card is not present, or the NVS protocol is disabled, the access server attempts to obtain these files using other protocols in this order: DTFTP, XMOP, MOP, BOOTP, RARP. All of these protocols except DTFTP are enabled by default. If you use the keyword ALL to enable all protocols, you also enable DTFTP. You cannot use DTFTP to load the parameter file except on the Network 9000 Access Server 720 which doesn’t have NVS. If you do enable DTFTP, specify the following IP addresses:

·

The load host

·

The access server

·

The gateway router to the load host, if necessary

Use the DEFINE SERVER LOAD IP commands to specify this information.

0038

109

Page 110

Getting Started with MAXserver Access Servers

Syntax DEFINE SERVER LOAD[record][usage]PROTOCOL[protocol-name][ENABLED] [DISABLED]

Where

Means record

Use one or more of the following initialization records: PRIMARY SECONDARY TERTIARY ALL The PRIMARY initialization record is the default.

usage

Use one of the following keywords, which indicate whether you are specifying a protocol for a software load image or a parameter file: IMAGE PARAMETERS

110