Page 91

Getting Started with MAXserver Access Servers

To modify the access server configuration, complete the following steps: 1. Type 2 at the "Enter menu selection" prompt of the Access server Configuration Menu. The unit displays the Modify Unit Configuration Menu, as shown Figure 32. Modify Unit Configuration Menu 1. Initialization record #1 (Enabled) 2. Initialization record #2 (Disabled) 3. Initialization record #3 (Disabled) M. Miscellaneous unit configuration D. Set unit configuration to defaults X. Exit to main menu Enter menu selection [X]:

Figure 32 - The Modify Unit Configuration Menu 2. If you select either 1, 2, or 3 the unit prompts you for a response. The record number displayed depends on which initialization configuration (1,2,or 3) you choose to modify): SET INITIALIZATION RECORD #1 TO DEFAULTS (Y,N) [N]? SET INITIALIZATION RECORD #2 TO DEFAULTS (Y,N) [N]? SET INITIALIZATION RECORD #3 TO DEFAULTS (Y,N) [N]? If you type ‘Y’ - The unit returns all configuration options to their factory default values. See Table 1 for the factory default settings. If you type N - The unit displays one of the following prompts (depending on which initialization record you choose to modify): ENABLE INITIALIZATION RECORD #1 (Y,N) [Y]? ENABLE INITIALIZATION RECORD #2 (Y,N) [Y]? ENABLE INITIALIZATION RECORD #3 (Y,N) [Y]? 3. Valid answers to this prompt are Y (Yes) and N (No). ‘Y’ - Enables the specified initialization configuration. Press any key to return to the Modify Unit Configuration Menu.

0038

91

Page 92

Getting Started with MAXserver Access Servers

‘N’ - Disables the specified initialization configuration and lets you create your own configuration. See “Creating a Customized Configuration” to continue.

Creating a Customized Configuration This section explains how to create a custom configuration for the MAXserver access server. You can customize the following values for up to three initialization records:

·

Enable all image loading types or only specific methods (e.g., CARD, DTFTP, RARP)

·

Enable all parameter loading methods or only specific parameter loading methods (e.g., NVS, XMOP, MOP)

·

Enable all dumping methods or only specific dumping methods (e.g., XMOP, TFTP, BOOTP)

·

Define a load file name (if you selected Card, XMOP or MOP loading methods)

·

Define IP addresses for the unit, host and gateway (if you selected TFTP as the loading method)

Defining the Image Loading Method You can change the method the MAXserver uses to load its software. For example, you can configure the unit to load exclusively from a specific type of load server or from the flash card only. Use the Access server Configuration menu to change the software loading method. Alternatively, you can use DEFINE SERVER commands to change the software loading method. (See Command Line Interface section of this guide for a description of the commands you can use at the Xyplex> prompt to display, monitor and define the unit’s configuration. 92

0038

Page 93

Getting Started with MAXserver Access Servers

The following table lists the factory-default protocol settings: Table 6 - Default Protocols Software Load Image

Parameter File

Dump file

CARD XMOP MOP BOOTP RARP DTFTP*

NVS XMOP MOP BOOTP RARP

XMOP MOP BOOTP RARP

*Not enabled by default. Software Load Images The following load image protocols are enabled at the factory.

·

CARD indicates the flash card

·

XMOP indicates another Xyplex loader

·

MOP indicates a VAX/VMS host

·

RARP, BOOTP and DTFTP indicate UNIX hosts.

Each initialization record has several loading and dumping protocols enabled by default if the access server attempts to obtain software and parameters from the network. Enabling/Disabling Image Loading Protocols The unit displays the following prompt: Enable ALL methods for image loading (Y,N) [N]?

0038

93

Page 94

Getting Started with MAXserver Access Servers

The following table lists the six methods available for loading images. Table 7 - Image Loading Methods Loads softare from¼

Method C

Flash card.

D

TFTP.

X

Xyplex MAXserver Manager or from another unit that has a flash card and the proper load image.

M

DEC MOP loader protocol.

B

BOOTP host

R

RARP.

‘Y’ - All software loading methods will be used. Proceed to the next section to continue the configuration ‘N ‘ - You are selecting specific method(s). The configuration menu prompts: Toggle (CARD,DTFTP,XMOP,MOP,BOOTP,RARP) image load methods [C,D,X,M,B,R]: NOTE:

Host setup activity is required for MOP, BOOTP, and RARP protocols.

1. Select specific protocol(s) by removing letters from or adding letters to the brackets. To remove a letter, type the letter and press RETURN. The prompt reappears; however, the letter you typed does not appear within the brackets. To add a letter to those within the brackets, type the letter and press RETURN. The prompt reappears and the letter you typed is included within the brackets. 2. Press RETURN again, the unit prompts you to enable parameter loading methods. Proceed to the next section to continue. 94

0038

Page 95

Getting Started with MAXserver Access Servers

Defining Parameter Loading Methods This section describes how to specify the unit’s parameter loading methods. All MAXserver units are configured at the factory to store configuration data (parameters) locally in Non-volatile storage (NVS). Alternatively, you can use DEFINE SERVER commands to change the parameter loading method. See the Commands Reference Guide for a complete listing of DEFINE SERVER commands. As an option, you can configure the unit to load parameters from a network host, called a parameter server, using the Access server Configuration Menu. Once you have selected the image loading methods and pressed Return, the unit displays the following prompt: Enable ALL methods for parameter loading (Y,N) [Y]? ‘Y’ - All methods are selected. ‘N’ - You can select specific method(s). The configuration menu prompts: Toggle (NVS,XMOP,MOP,BOOTP,RARP)parameter load methods [N,X,M,B,R]: The valid methods are listed in the following table. You can select up to four loading methods. Table 8 - Parameter Loading Methods

0038

Value

Stores and Loads Parameters

N

From Non-volatile storage (NVS) located within the unit.

X

At a MAXserver Manager or or from another unit that has a flash card and the proper load 95

Page 96

Getting Started with MAXserver Access Servers image. M B (Bootstrap Protocol) R (RARP

From the MOP -DEC Maintenance Operations Protocol (DEC MOP) loader protocol. At a BOOTP/TFTP host. From Reverse Address Resolution Protocol (RARP/TFTP).

1. Select specific protocol(s) by removing letters from or adding letters to the brackets. To remove a letter, type the letter and press RETURN. The prompt reappears, however, the letter you typed does not appear within the brackets. To add a letter to those within the brackets, type the letter and press RETURN. The prompt reappears and the letter you typed is included within the brackets. 2. When the letters within the brackets represent all the protocols you want to use, press RETURN. The unit then redisplays the prompt showing the protocols you specified. Press RETURN again. The unit prompts you to define dumping methods. Proceed to the next section to continue the configuration.

Defining Dumping Methods This section describes how to define the unit’s dumping methods.. Once you have selected the parameter loading methods and pressed RETURN, the unit displays the following prompt: Enable ALL methods for dumping (Y,N) [Y]? 1. Type Y to select all methods, or type N to select specific method(s). The valid methods are listed in Table 9. You can select up to four dumping methods.

96

0038

Page 97

Getting Started with MAXserver Access Servers

Table 9 - Dumping Methods Value

Description

X

Dumps its memory contents to a MAXserver Manager when a crash occurs (you cannot enable dumping to a flash card).

M

Dumps memory contents via the DEC MOP loader protocol.

B

Dumps memory contents at a BOOTP host.

R

Dumps memory contents via RARP.

2. If you choose to use a specific method(s), the configuration menu prompts: TOGGLE (XMOP,MOP,BOOTP,RARP)DUMP LOAD METHODS [X,M,B,R]: 3. Select specific methods(s) by removing letters from or adding letters to the brackets. To remove a letter, type the letter and press RETURN. The prompt reappears, however, the letter you typed does not appear within the brackets. To add a letter to those within the brackets, type the letter and press RETURN. The prompt reappears and the letter you typed is included within the brackets. 4. When the letters within the brackets represent all the protocols you want to use, press RETURN. 5. If you selected the CARD, XMOP, or MOP loading method(s), proceed to “Defining the CARD/XMOP/MOP Image Filename” to continue the configuration. If you selected BOOTP, TFTP or RARP as your loading method, proceed to “Defining IP Addresses” to continue the configuration. Defining The CARD/XMOP/MOP Image Filename

0038

97

Page 98

Getting Started with MAXserver Access Servers

This section describes how to define the image filename if you selected CARD, XMOP or MOP as the loading method. Once you have selected the dumping methods and pressed RETURN, the unit displays the following prompt (if you selected CARD, XMOP or MOP as the unit’s loading method). CARD/XMOP/MOP IMAGE FILENAME (16 CHARACTERS MAX) [XPCSRV20]: 1. Enter a file name or a numerical value. The valid responses are as follows: Valid filenames Valid filenames consist of up to 16 characters, which can be letters and numbers, the underscore character (_), the hyphen character (-), and the period (.) character. The default load file name is XPCSRV20. (The actual name of the load file is XPCSRV20.SYS.) Numerical Values In place of a filename, you can specify a numerical value. A numerical value specifies to a Xyplex loader (another unit which has a flash card and the proper load image, or a MAXserver Manager card) that it should determine the appropriate load file based on:

·

The requesting unit's hardware type, or

·

A node entry in the client database of a Xyplex loader.

You can also use numerical values to specify that a MOP (Maintenance Operations Protocol) loader is to determine the appropriate load file based on information contained in the NCP (Network Control Program) database.

98

0038

Page 99

Getting Started with MAXserver Access Servers

Valid numerical values consist of the pound-sign character (#) and a number in the range of 0 through 128. Xyplex load servers respond to the numbers 1 through 5. The following table describes these values. Table 10 - Image File Naming Conventions Numerical Value 1

2 through 4 5

6 through 128

Description Allows you to specify a load file name via the NCP commands at a VAX/VMS load server, or via client entries on a Xyplex loader. This is the default. Reserved for use by NBase-Xyplex Requires a load server to ignore the load request -unless the load server's client database contains a node entry for the requesting access server. (The numerical value 5 is useful when you want to require that a specific load server be used to load the unit.) Undefined.

2. Enter a valid filename and press RETURN. The unit returns you to the Access server Configuration Menu. This completes the configuration of the access server. 3. If you enabled all image loading protocols or specified TFTP as the loading protocol, proceed to “Defining IP Addresses.”

Defining IP Addresses If you enabled all image loading protocols or specified DTFTP as the loading protocol, you must supply a non-zero Internet address for the unit, load host and gateway (if the load host is not on the same network as the unit. If Directed TFTP is enabled, the following prompt appears: ENTER UNIT IP ADDRESS [0.0.0.0]:

0038

99

Page 100

Getting Started with MAXserver Access Servers

1. Enter the access server’s IP address, or press RETURN to accept the default address, 0.0.0.0. You must supply a non-zero IP address if you have specified all image loading protocols or DTFTP as an image loading method. 2. Enter the load host’s IP address, or press RETURN to accept the default address, 0.0.0.0. You must supply a non-zero IP address if you have specified all image loading protocols or DTFTP as an image loading method. ENTER HOST IP ADDRESS [0.0.0.0]: 3. If the load host is not on the same network as the unit, enter the Internet address of a gateway. ENTER GATEWAY IP ADDRESS [0.0.0.0]: 4. Enter the name of the file to load (max. 64 characters). ENTER TFTP LOAD FILENAME []: 5. After you have specified a filename and pressed the RETURN key, the menu prompts: (TYPE ANY KEY TO CONTINUE) 6. Press any key to return to the Modify Unit Configuration Menu

Miscellaneous Unit Configuration The Modify Unit Configuration Menu, is where you can change the following unit settings:

100

·

Enable/Disable Status Message display.

·

Configure the amount of memory installed in the unit.

0038