Page 71

Status Screens PollCat NetLink-VIP Version 1.06 DATA FILTERS & ALARMS:

11/08/2005 Tue 11:36

FILTERS & ALARMS Alarm Filter 1: Alarm Filter 2: Data Filter 1: Data Filter 2: PBX Inact Alarm 1: PBX Inact Alarm 2:

DEFAULT ALARM FILTER ACTION Action: None Phone #: (undefined) (Cont.): Pager ID 1: (undefined) Pager ID 2: (undefined) Pager ID 3: (undefined) SNMP Mgmt: Manager #1 Output Contacts 1/2/3/4: -/-/-/Message: (undefined) (Cont.): (Cont.): Auto Execute: Off Execute Cmds: (undefined) (Cont.): (Cont.): (Cont.): Send Alarm Records: Off,2048,On,Off Email To: Email #1

PORT None None None None None None

OTHER ALARMS 80% Full Alarm: Off Input Contact Alrm: Off OUTPUT CONTACTS (IDLE/NO ALARM) Contacts 1/2/3/4: C/C/C/C CONTACTS CURRENT STATE (1/2/3/4) Input Contact: H/L/H/L Output Contacts: C/C/C/C Press <Enter> to return to menu ...

1% Full

Figure 7.7: Data Filters & Alarms Status Screen

7.6. Data Filters & Alarms Status Screen As shown in Figure 7.7, this screen displays parameters for the Data Filters, Alarm Filters, PBX Inactivity Alarms, 80% Full Alarm, and Input Contact Alarm. The screen also lists Default Alarm Filter Actions, and shows the status of the optional Input and Output Contacts. • Filters & Alarms: Shows which port(s) are currently assigned to the Alarm Filters, Data Filters, and PBX Inactivity Alarms. If a Filter or Alarm is not currently assigned, the Port column will read "NONE". • Other Alarms: The On/Off status of the 80% Full Alarm and Input Contact Alarm. • Output Contacts: The Idle/Non-Alarm state for the output contacts (Optional; not available on NLJ-VIP Models.) • Contacts Current State: The High/Low status of the optional Input Contacts, and Open/Closed status of the optional Output Contacts. (Optional; not available on NLJ-VIP Models.) • Default Alarm Filter Action: The VIP will use these defaults for all new alarm clues. Action: The default action performed when an alarm is generated; None, Callout, Alphanumeric Page, Numeric Page, SNMP Trap, Output Contact, Console action or Email/Text Message. Phone Number: The default number that is dialed when the Alarm Filter generates a callout or page.

7-7

Page 72

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

Pager ID Numbers: The default ID numbers used when the Alarm Filter generates an alphanumeric page. SNMP Management: The default SNMP manager(s), which will receive SNMP Traps generated by Alarm Clues. Output Contacts: (Optional - not available on NLJ-VIP units) The default Output Contact action. A "C" indicates the contact will be closed when an alarm is generated, "O" indicates the contact will be opened, and a dash (-) indicates the status of the contact will not be changed. Message: The default message sent when the Alarm Filter generates a callout, alphanumeric page, SNMP Trap, or console port action. Auto Execute: The default On/Off state. When enabled, the VIP will execute a user-defined command string when a callout or console action is performed. Execute Commands: The default Auto-Execute command string. This command string will be performed when the Auto Execute feature is enabled, and a callout or console action is generated. Send Alarm Records: The On/Off status of the "Send Alarm Records" feature, which allows you to include the exact record that triggered the alarm when an Alphanumeric Page action is generated by the Alarm Filter. Email To: The default address(es) (defined via the Network Port configuration menu) that will receive email and text messages generated by this alarm.

7-8

Page 73

Status Screens PollCat NetLink-VIP ALARM CONDITION:

Version 1.06

11/08/2005 Tue 11:39

1% Full

ALARM PENDING Alarm Filter 1 (PBX-A): No Alarm Filter 2 (PBX-A): No Alarm Filter 1 (PBX-B): No Alarm Filter 2 (PBX-B): No Alarm Filter 1 (AUX): No Alarm Filter 2 (AUX): No PBX Inact Alarm 1: No PBX Inact Alarm 2: No 80% Full Alarm: No Input Contact Alrm: No Alarm Filter 1 (PBX IP): No Alarm Filter 2 (PBX IP): No

Press <Enter> to return to menu ...

Figure 7.8: Alarm Condition Status Screen

7.7. Alarm Condition Status Screen As shown in Figure 7.8, this screen lists alarm actions that have not been completed. For example, if the modem port is busy, and an alarm is generated which requires transmission via modem, the VIP will place the alarm in a queue to await processing. During this time, the Alarm Condition Status Screen will list the alarm action as "pending".

7-9

Page 74

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide PollCat NetLink-VIP Version 1.06 PBX INACTIVITY ALARM 1:

11/08/2005 Tue 11:39

SCHEDULE Weekday Alarm: Off Weekday Schedule 1: 00:00-00:00 Weekday Timer 1: 00:00 Weekday Schedule 2: 00:00-00:00 Weekday Timer 2: 00:00 Weekend Alarm: Off Weekend Schedule 1: 00:00-00:00 Weekend Timer 1: 00:00 Weekend Schedule 2: 00:00-00:00 Weekend Timer 2: 00:00

ALARM ACTION PARAMETERS Action: None Phone #: (undefined) (Cont.): Pager ID 1: (undefined) Pager ID 2: (undefined) Pager ID 3: (undefined) SNMP Mgmt: Manager #1 Output Contacts 1/2/3/4: -/-/-/Message: (undefined) (Cont.): (Cont.): Auto Execute: Off Execute Cmds: (undefined) (Cont.): (Cont.): (Cont.): Email To: Email #1

EXCLUSIONS (MM/DD) --/---/---/---/---/---/---/---/---/---/--

--/---/---/---/---/--

--/---/---/---/---/--

1% Full

Press <Enter> to return to menu ...

Figure 7.9: PBX Inactivity Alarm Status Screen (Alarm 1 Shown)

7.8. PBX Inactivity Alarm Status Screens As shown in Figure 7.9, these screens list parameters for the PBX Inactivity Alarms. The VIP includes two separate PBX Inactivity Alarms. Each alarm has its own status screen, which lists the following: • Schedule: On/Off Status, Schedules, and Timers for the Weekday and Weekend Alarms. • Exclusions: Dates (such as holidays) when alarms will be disabled. • Alarm Action Parameters: The action that will be performed when this alarm is triggered. Action: Selected alarm action; None, Callout, Alphanumeric Page, Numeric Page, SNMP Trap, Output Contact, Console action or Email/Text Message. Phone Number: The number dialed when the PBX Inactivity Alarm generates a callout or page action. Pager ID Numbers: The pager ID numbers used when this alarm generates an alphanumeric page. SNMP Management: The SNMP Manager(s) that will receive SNMP Traps generated by this alarm.

7-10

Page 75

Status Screens

Output Contacts: (Optional - Not available on NLJ-VIP units) A "C" indicates the contact will be closed, an "O" indicates the contact will be opened, and a dash (-) indicates that the status of the contact will not be changed (for more information, please refer to Section 11.) Message: Message sent when this PBX Inactivity Alarm generates a callout, alphanumeric page, SNMP Trap, or console action. Auto Execute: If enabled, the VIP will execute a user-defined command string when a callout or console action is generated. Execute Commands: The command string performed when Auto Execute is enabled, and a callout or console action is generated. Email To: The address(es) that will receive email and text messages generated by this alarm. This item is used to select one of two user-defined email messages that are defined via the Send Email configuration menu, as described in Section 5.4.5.1.

7-11

Page 76

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide PollCat NetLink-VIP 80% FULL ALARM: 80% Full Alarm: Action: Phone #: Pager ID 1: Pager ID 2: Pager ID 3: SNMP Mgmt: Output Contacts 1/2/3/4: Message: Auto Execute: Execute Cmds: (Cont.): Email To:

Version 1.06

11/08/2005 Tue 11:40

1% Full

Off None (undefined) (undefined) (undefined) (undefined) Manager #1 -/-/-/(undefined) Off (undefined) Email #1

Press <Enter> to return to menu ...

Figure 7.10: 80% Full Alarm Status Screen

7.9. 80% Full Alarm Status Screen As shown in Figure 7.10, this screen lists parameters for the 80% Full Alarm. For more information, please refer to Section 11. This status screen lists the following: • 80% Full Alarm: The enabled/disabled status of the alarm. • Action: The selected action that will be performed when an 80% Full Alarm is generated. • Phone Number: The number dialed when the 80% Full Alarm generates a callout or page action. • Pager ID Numbers: The ID numbers that are used when the 80% Full Alarm generates an alphanumeric page. • SNMP Manager: The SNMP manager that will receive SNMP Traps generated by this alarm. • Output Contacts: (Optional - Not available on NLJ-VIP units) The Output Contact action that can be performed when this alarm is triggered. A "C" means the contact will be closed, an "O" means the contact will be opened, a dash (-) means that the status of the contact will not be changed. • Message: The message sent when this alarm generates a callout, alphanumeric page, SNMP Trap, or console action. • Auto Execute: The On/Off state of the Auto Execute feature. • Execute Commands: A command string that can be automatically executed when the 80% Full Alarm is triggered.

7-12

Page 77

Status Screens PollCat NetLink-VIP INPUT CONTACT ALARM:

Version 1.06

Contact 1 Alarm: Trigger Level 1:

Off Low

Contact 2 Alarm: Trigger Level 2:

Off High

Contact 3 Alarm: Trigger Level 3:

Off Low

Contact 4 Alarm: Trigger Level 4:

Off High

11/08/2005 Tue 11:41

1% Full

Press <Enter> to return to menu ...

Figure 7.11: Input Contact Alarm Status Screen

7.10. Input Contact Alarm Status Screen As shown in Figure 7.11, this screen shows the status of the Input Contact Alarms described in Section 12. The Status Screen lists the following: Note: The Input Contact feature is optional on NetLink-VIP units, and is not available on NLJ-VIP units. • Contact Alarms (1 - 4): Indicates if the Input Contact Alarm is enabled for the corresponding Input Terminal. • Trigger Levels (1 - 4): Lists the contact state that will trigger an alarm at the corresponding Input Terminal.

7-13

Page 78

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide PollCat NetLink-VIP REASON FOR ACTION

Version 1.06

11/08/2005 Tue 11:42

1% Full

Alarm Action: PBX Record Matched the Following Filter: Alarm Filter: Clue Name: Match Count: Message:

1 ALPHA 98 ALARM ALPHA

Press <ENTER> to return to previous menu ...

Figure 7.12: Reason for Action Screen

7.11. Reason for Action Screen This screen (Figure 7.12) can be used to determine the exact reason for an alarm. Note that if an Alarm or Scheduled Action has not occurred, the VIP will display a message which reads, "Session Not Initiated by the VIP." The Reason for Action Screen includes the following: • Alarm Action: A brief description of the last alarm action or scheduled action performed by the VIP. • Alarm Filter: The alarm filter that generated the action. • Clue Name: The clue that generated the alarm action. • Match Count: The counter value for the clue. • Message: The user-defined alarm message for the clue that generated the alarm action.

7-14

Page 79

Status Screens PollCat NetLink-VIP PBX PORT A:

Version 1.06

11/08/2005 Tue 11:43

1% Full

COMMUNICATION SETTINGS Com Settings: 9600,E,7,1,None INPUT PARAMETERS Time/Date Stamp: Serial # Stamp: Strip Non-Print: End Character: Alarm Filter: Store Alarm Data: Data Filter: PBX Inact Alarm:

Off Off On ^J None Alarm None None

Press <Enter> to return to menu ...

Figure 7.13: PBX Port Status Screen (PBX Port A Shown)

7.12. PBX Port Status Screens These screens list parameters for the PBX Ports. There are separate status screens for PBX Ports A and B. As described in Section 5.4.1, port parameters are selected via the Port Configuration menus. Note: NLJ-VIP units do not include PBX Port B. • Communication Settings: Lists Baud Rate, Parity, Data Bits, Stop Bits, and Handshake Mode for this port. • Input Parameters: Selected input parameters for this port: Time Date Stamp: When enabled, the VIP will insert a Long Format or Short Format Time/Date Stamp at the beginning of each record received via this port. Serial Number Stamp: When enabled, a serial number will be inserted at the beginning of each record received by this port. Strip Non-Print: When enabled, the VIP will remove non-printable characters from all records received via this port. End Character: The selected End-of-Record character for this port. Alarm Filter: The Alarm Filter selected for this port. Store Alarm Data: Indicates where the VIP will store alarm records received via this port. Data Filter: The Data Filter selected for this port. PBX Inact Alarm: The On/Off status of the PBX Inactivity Alarm for this port.

7-15

Page 80

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide PollCat NetLink-VIP AUXILIARY PORT:

Version 1.06

11/08/2005 Tue 11:43

1% Full

COMMUNICATION SETTINGS Com Settings: 9600,E,7,1,None INPUT PARAMETERS Time/Date Stamp: Serial # Stamp: Strip Non-Print: End Character: Alarm Filter: Store Alarm Data: Data Filter: PBX Inact Alarm: Port Mode:

Off Off On ^J None Alarm None None Store Data

Press <Enter> to return to menu ...

Figure 7.14: Auxiliary Port Screen

7.13. Auxiliary Port Status Screen This screen lists parameters for the Auxiliary Port. Parameters are selected via the Port Configuration menu (Section 5.4.2). Note: NLJ-VIP units do not include the AUX Port. • Communication Settings: Lists Baud Rate, Parity, Data Bits, Stop Bits, and Handshake Mode for the Auxiliary Port. • Input Parameters: Lists input parameters for this port: Time Date Stamp: When enabled, the time and date will be inserted into records received via this port. Serial Number Stamp: When enabled, a serial number will be inserted into records received via this port. Strip Non-Print: When enabled, the VIP will remove non-printable characters from all records received via this port. End Character: The selected End-of-Record character for this port. Alarm Filter: The Alarm Filter selected for this port. Store Alarm Data: Indicates where the VIP will store alarm records received via this port. Data Filter: The Data Filter selected for this port. PBX Inact Alarm: The PBX Inactivity Alarm selected for this port. Port Mode: The selected operation mode for the AUX Port; either Store Data or Discard Data. 7-16