Page 191
Other Menu Functions TEST PAGER 1. 2. 3. 4.
Phone #: Pager ID #: Type: Start Test
(undefined) (undefined) Alpha
Enter Selection, Press <ESC> to return to previous menu ...
Figure 17.3: Pager Test Menu
17.2.3. Test Pager The Test Pager function sends a test message or number to your alphanumeric or numeric pager. When testing an alphanumeric pager, the VIP will send the message "Test Page from PollCat the VIP". When testing a numeric pager, the VIP can send a numeric message entered at the Phone Number prompt. To initiate the pager test, go to the System Diagnostics menu, type 3 and press [Enter]. The VIP will display the screen shown in Figure 17.3. Enter parameters for the Pager Test as follows: 1.
Phone #: The phone number for your numeric pager or alphanumeric pager service. Type 1, press [Enter], and follow the instructions in the submenu. a)
For numeric pagers, this prompt can specify both the pager number and a numeric "message". In this case the phone number is entered as follows: PHONENO@MESSAGENO#
Where PHONENO is the pager number, and MESSAGENO is any user-selected number. For example, to dial 555-1212 and send the message "333", the phone number would be "5551212@333#". 2.
Pager ID #: When testing an alphanumeric pager, this item defines the Pager ID number. Type 2, press [Enter], and follow the instructions in the submenu. Note that this prompt is not used when testing a numeric pager.
3.
Type: Selects a numeric or alphanumeric pager test. Type 3, press [Enter], and follow the instructions in the submenu.
4.
Start Test: After entering the appropriate information at the prompts, type 4 and press [Enter] to initiate the pager test. To cancel a test in progress, use the "Clear Alarm Condition" function as described in Section 17.1.4.
17-9
Page 192
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
17.2.4. Send Test SNMP Trap(s) This function will send a test SNMP trap to the network manager(s). In order to function, SNMP Managers must first be defined and selected as described in Section 5.4.5. When this function is executed, the VIP will send an SNMP Trap to each defined SNMP Manager.
17.3. Default Parameters Main Menu item 21 will reset all the VIP parameters to default settings. This function offers the option to include or omit network parameters and Alarm Filter and Data Filter configurations. To reset parameters to defaults, type 21, press [Enter] and follow the instructions in the submenu.
17-10
Page 193
18. TCP Port Options The VIP offers three optional functions, which can be used when communicating with the unit via Telnet; the Telnet Pass-Through Mode, the Real Time Mode, and the Selective Read Mode. All of these options are selected by entering the appropriate Telnet Port Number in the Telnet command line, as described in the sections that follow. Notes: • Telnet ports 23, 2001, and 3001 allow normal access to the VIP command mode. However, Port 3001 will transfer data using "Raw Socket" mode. • Telnet Pass-Through Mode, Real Time Mode, and Selective Read Mode use the same System and User Passwords as are normally used to log on to the VIP. • The Telnet Pass-Through Mode, Real Time Mode and Selective Read Mode all support XON/XOFF flow control. • NLJ-VIP units do not include PBX Port B or the AUX Port.
18.1. Standard Telnet Protocol & Raw Socket Mode The Telnet Pass-Through Mode, Real Time Mode, and Selective Read Mode all offer the option to send data using either Standard Telnet Protocol or Raw Socket Mode. The port number entered in the telnet connect command determines which protocol is used. When Standard Telnet Protocol is used, the VIP will receive and reply to all IACs. When Raw Socket Mode is used, data is always sent "as is", and command echo is always enabled.
18-1
Page 194
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
18.2. Telnet Pass-Through The Telnet Pass-Through function allows users to communicate directly with devices connected to PBX Port A, PBX Port B, the AUX Port, the PBX IP Port, the Console Port, or the Modem Port. All VIP menu functions are disabled, and the only VIP command that will be recognized is ^B30 (Exit Pass-Through and Disconnect Telnet Session). In addition, data can be sent using either Standard Telnet Protocol or Raw Socket Mode. When a Telnet connection is established, using the Telnet Pass-through option, the following events will occur: 1.
Upon connection, the VIP will send the "POLLCAT NETLINK" message (and the site ID, if defined) and then wait for a password.
2.
If a valid password is entered, the VIP will send the "READY" message, and will then allow communication with the device connected to the specified port.
Port Numbers for Telnet Pass-Through Function This function is activated when one of the following port numbers is included in the Telnet connect command. Standard Telnet Protocol: Telnet Port No.
Function
2101
Pass-Through to PBX Port A
2102
Pass Through to PBX Port B
2103
Pass-Through to AUX Port
2104
Pass-Through to Console Port
2105
Pass-Through to Modem Port
2106
Pass-Through to PBX IP Port
Raw Socket Mode: Telnet Port No.
18-2
Function
3101
Pass-Through to PBX Port A, Raw Socket
3102
Pass-Through to PBX Port B, Raw Socket
3103
Pass-Through to AUX Port, Raw Socket
3104
Pass-Through to Console Port, Raw Socket
3105
Pass-Through to Modem Port, Raw Socket
3106
Pass-Through to PBX IP Port, Raw Socket
Page 195
TCP Port Options
18.3. Real Time Mode The Real Time Mode allows Telnet users to receive data as soon as it is collected from the PBX; as each data item is collected, it is sent directly to the user via Telnet. Data can be read from PBX Port A, PBX Port B, PBX IP Port or the AUX Port. Notes: • In the Read Time Mode, data can be sent using either Standard Telnet Protocol, or Raw Socket Mode, depending on the port number entered in the Telnet connect command. • If the buffer for the target port already contains data, the VIP will first send the buffered data, and then switch to Real Time Mode after the buffered data has been completely sent. • In Real Time Mode, all VIP menus, status screens and ^Bnn commands are suppressed. • In Real Time Mode, the Auto Delete function is always enabled. When a Telnet connection is established using the Real Time Mode option, the following events will occur: 1.
Upon connection, the VIP will send "POLLCAT-NETLINK" message (and the site ID, if defined), and then wait for a password.
2.
If a valid password is entered, the VIP will send the "READY" message, and then wait for an XON from the user before beginning data release.
3.
When an XON is received, the VIP will pause for 5 seconds (to wait for client software to be ready), then begin sending data.
4.
The connection will remain open indefinitely, or until the client disconnects using their telnet software.
5.
If the telnet session is disconnected (either due to a user command or accidentally), the VIP will store additional data in buffer memory as it would normally.
18-3
Page 196
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
Port Numbers for the Real Time Mode The Real Time Mode is activated when one of the following port numbers is included in the Telnet connect command. Standard Telnet Protocol: Telnet Port No.
Function
2201
Real Time Mode; PBX Port A.
2202
Real Time Mode; PBX Port B.
2203
Real Time Mode; AUX Port.
2206
Real Time Mode; PBX IP Port
Raw Socket Mode: Telnet Port No.
18-4
Function
3201
Real Time Mode; PBX Port A, Raw Socket.
3202
Real Time Mode; PBX Port B, Raw Socket.
3203
Real Time Mode; AUX Port, Raw Socket.
3206
Real Time Mode; PBX IP Port, Raw Socket
Page 197
TCP Port Options
18.4. Selective Read This function allows Telnet users to read a selected type of buffered data from the VIP unit. In other words, the Selective Read function automatically sets a data partition based on the port number specified in the Telnet connect command. Data can be selected according to data type and the VIP port which originally received the data. The following data types can be selected: • All: Both alarm data and non-alarm data. • Standard: Non-alarm data. • Alarm 1: Data which matched Alarm Filter One. • Alarm 2: Data which matched Alarm Filter Two. Notes: • When the Selective Read Mode is active, all VIP command menus, status screens and ^Bnn commands will function normally. • In Selective Read mode, Data can be sent in either Standard Telnet Protocol or Raw Socket Mode, depending on the port number entered in the Telnet connect command. • The Selective Read Mode will use the polling parameters currently selected by the Network Port Configuration menu. • If the Auto Delete function is enabled at the target input port, data will be automatically deleted as soon as the polling device acknowledges reception. • A Partition will not be set if the desired data file is empty. Even though the partition is automatically set, it is recommended to invoke command ^B01 using the appropriate arguments for the desired data. When a Telnet connection is established using the Selective Read option, the following events will occur: 1.
Upon connection, the VIP will send "POLLCAT NETLINK" (and the site ID, if defined) and then wait for a password.
2.
If a valid password is entered, the VIP will send the "READY" message, and set the data partition as specified by the port number used in the Telnet connect command.
Port Numbers for Selective Read Function The Selective Read function is activated when one of the port numbers, shown in the tables on the next page, are included in the Telnet connect command. 18-5
Page 198
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
Standard Telnet Protocol: Telnet Port No.
Function
2301
Selective Read; PBX Port A, All Data
2302
Selective Read; PBX Port B, All Data
2303
Selective Read; AUX Port, All Data
2306
Selective Read; PBX IP Port, All Data
2311
Selective Read; PBX Port A, Standard Data
2312
Selective Read; PBX Port B, Standard Data
2313
Selective Read; AUX Port, Standard Data
2316
Selective Read; PBX IP Port, Standard Data
2321
Selective Read; PBX Port A, Alarm 1 Data
2322
Selective Read; PBX Port B, Alarm 1 Data
2323
Selective Read; AUX Port, Alarm 1 Data
2326
Selective Read; PBX IP Port, Alarm 1 Data
2331
Selective Read; PBX Port A, Alarm 2 Data
2332
Selective Read; PBX Port B, Alarm 2 Data
2333
Selective Read; AUX Port, Alarm 2 Data
2336
Selective Read; PBX IP Port, Alarm 2 Data
Raw Socket Mode: Telnet Port No.
18-6
Function
3301
Selective Read; PBX Port A, All, Raw Socket
3302
Selective Read; PBX Port B, All, Raw Socket
3303
Selective Read; AUX Port, All, Raw Socket
3306
Selective Read; PBX IP Port, All, Raw Socket
3311
Selective Read; PBX Port A, Standard, Raw Socket
3312
Selective Read; PBX Port B, Standard, Raw Socket
3313
Selective Read; AUX Port, Standard, Raw Socket
3316
Selective Read; PBX IP Port, Standard, Raw Socket
3321
Selective Read; PBX Port A, Alarm 1, Raw Socket
3322
Selective Read; PBX Port B, Alarm 1, Raw Socket
3323
Selective Read; AUX Port, Alarm 1, Raw Socket
3326
Selective Read; PBX IP Port, Alarm 1, Raw Socket
3331
Selective Read; PBX Port A, Alarm 2, Raw Socket
3332
Selective Read; PBX Port B, Alarm 2, Raw Socket
3333
Selective Read; AUX Port, Alarm 2, Raw Socket
3336
Selective Read; PBX IP Port, Alarm 2, Raw Socket
Page 199
TCP Port Options
18.5. Multiple Telnet Connections When the Telnet Pass-Through Mode, Real Time Read Mode, or Selective Read Mode are active, additional telnet connections will be allowed in some cases and denied in others as described below: 1.
Telnet Pass-Through Mode: When the Telnet Pass-Through Mode is connected to the target Port (Port A, B, PBX IP or AUX), additional telnet connections will be allowed or denied as follows: • Real Time Mode: Is not allowed to connect to the target port. • Selective Read Mode: Is allowed to connect to the target port.
2.
Real Time Mode: When the Telnet Real Time Mode is connected to the target port (Port A, B, PBX IP or AUX), additional telnet connections to the target port will be denied.
3.
Selective Read Mode: When the Selective Read Mode is connected to the target port (Port A, B, PBX IP or AUX), additional Telnet connections will be allowed or denied as follows: • Pass Through Mode: Is allowed to connect to target port. • Real Time Read Mode: Not allowed to connect to target port.
18-7
Page 200
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
18.5.1. Conflicts with Other Command Ports When another user has accessed command mode via the Console Port, Modem Port, or Telnet Ports 23, 2001, or 3001, Telnet Pass-Through Mode, Real Time Read, and Selective Read Mode will behave as follows: 1.
Normal Pass-Through Mode: If the Console Port, Modem Port, or Telnet Ports 23, 2001, or 3001 have activated normal Pass-Through Mode (non-Telnet; see Section 16.1.2.) to access the target port, Telnet connections will be handled as follows: • Telnet Pass-Through Mode: Not allowed to connect to port. • Real Time Mode: Not allowed to read data from target port. • Selective Read Mode: Is allowed to read data from target port.
2.
Partitioned Data: If the Console Port, Modem Port, or Telnet Ports 23, 2001, or 3001 have used the VIP Configuration menus or ^Bnn commands to set a partition which includes data received from the target port, Telnet connections will be handled as follows: • Telnet Pass-Through Mode: Is allowed to connect to target port. • Real Time Mode: Not allowed to read data from target port. • Selective Read Mode: Not allowed to read data from target port.