Page 221

This page is a scan with no text; see it in the PDF.

Page 222

Appendix O

ASCII Code Equivalent Table The 128 ASCII codes and their 3 digit decimal equivalents are detailed in the below table. The RS232 Models use the ASCII; the keyboard wedge models have some of the unprintable ASCII characters reassigned to specific keys, (i.e. SOH is f1). char hex

3 digit ASCII char hex

3 digit ASCII char hex

3 digit ASCII char hex

3 digit ASCII

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031

SP ! " # $ % & ' ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 059 060 061 062 063

@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _

40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F

064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082 083 084 085 086 087 088 089 090 091 092 093 094 095

‘ a b c d e f g h i j k l m n o p q r s t u v w x y z } | { ~ DEL

60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F

096 097 098 099 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

Table H-1. Full ASCII Equivalent Table

O-1

Page 223

This page is a scan with no text; see it in the PDF.

Page 224

Appendix P

Piggyback Laser Installation The TriCoder can use a hand-held Laser scanner (such as the LZ100, LZ200 and 3200 models) in what we call a "Piggyback" configuration. This configuration has the TriCoder connected to the laser with a short cable and Velcro strips to secure the TriCoder to the top of the laser. This creates an all-in-one TriCoder/Laser scanner. Follow these steps to complete the Piggyback installation: 1.

If the normal long coiled laser cable is still plugged into the LZx00 laser, use a pencil or flat head screwdriver to depress the tab on the RJ45 connector of the cable at the base of the laser scanner. Pull out the cable while depressing the tab.

2.

Insert the untagged end of the T24 Piggyback cable into the laser. This cable is considerably shorter than the original laser cable.

3.

Place the Velcro strips on the top of the laser and the back of the TriCoder separately according to the diagram below. Firmly press on the Velcro surface to be sure the sticky back makes complete contact with the surface of the laser and TriCoder.

4.

Plug the tagged end of the T24 Piggyback cable into the TriCoder SCANNER port.

A carrying case, the T48 is available for this configuration. It is a one piece carrying case designed to help stabilize and protect the Tricoder and Laser. See Appendix E for greater detail.

P-1

Page 225

This page is a scan with no text; see it in the PDF.

Page 226

Appendix Q

RS-422 Using the TriCoder with an RS-422 board instead of a standard RS-232 serial port allows multiple TriCoders to be multi-dropped off of a single RS-422 port at a distance up to 4000 feet. Multiple TriCoders can then be polled periodically while they are collecting data. To be used with a RS-422 board, the TriCoder must have the 422 option factory installed. RS-422 boards are available from a variety of sources. Worth Data sells a board as well as the cable from the 422 board to the first 422 T-Cable. Because the specifications vary for different RS-422 boards, we recommend getting the board and cable from us to eliminate problems with communication. The biggest problem we see with RS-422 multi-dropping has to do with cabling. Follow the specifications for the cabling exactly as they are shown. Use only the wire specified (don’t use whatever is lying around) and be sure to test your communications thoroughly before going on-line with a large installation. You can use the following pin-outs to create your own RS-422 multi-drop cables or you can order RS-422 “T” cables (part #F44) from us: 1.

Tying T+ on the TriCoder end to the R+ on the continuous 422 line.

2.

Tying T- on the TriCoder end to the R- on the continuous 422 line. Function

Mod 8

Transmit Data + (T+) Transmit Data - (T-) Ground Receive Data + (R+) Receive Data - (R-)

2 3 4 5 6

Table N-1. RS-422 Multi-drop cable You must have T+/T- in one twisted pair and R+/R- in the other. We suggest using our F44 422 "Y" Cable instead. One end of this cable goes into the TriCoder, the other 2 ends have female modular 8 pin connectors. The only cables you provide are cables with male modular 8 pin connectors on each end to connect between TriCoders and a cable coming from the 422 serial port with a male modular 8 pin connector to connect to the first TriCoder. At the end of the string of TriCoders, tie pins 2&3 and 5&6 together with 120 ohm resistors or order our 422 terminator plug. Use Belden 1227AI or Cat 5 wire for all of the 422 cabling above.

Q-1

Page 227

This page is a scan with no text; see it in the PDF.

Page 228

Appendix R

Polling and how it works Polling is the operation where a TriCoder records data (either scanned or entered on the keypad) and buffers it until the host computer asks the TriCoder to transmit the data. The request for the data from the host is called a "poll". The TriCoder then transmits its data (along with its ID character to identify which TriCoder the data came from) to the host and goes on to record another piece of information and wait for it's next poll. Polling is not considered a "portable" operation and requires that you use the 5 volt power adapter with the TriCoder. Polling works only with serial interface readers.

Polling with the TriCoder Here is what polling looks like on the TriCoder: The TriCoder reads a code, beeps once, and displays the data on the 1st line and WAITING ON POLL on the 2nd line. The TriCoder stores the data in its buffer, waiting for the host to ask for it. For the purposes of this explanation, let's suppose that the person using a TriCoder with the ID character “a” just read the bar code 123456 and the person using TriCoder “b” is on a lunch break. The software running on the host computer transmits each of your TriCoders' ID characters one by one over the serial port. As each TriCoder's ID character is transmitted, the TriCoder with the matching ID character responds with one of the following: 1.

If the TriCoder has no data in its buffer to transmit, it sends back its ID CHARACTER only.

2.

If the TriCoder has data to transmit, it sends back its ID CHARACTER followed by the data.

When the host program transmits an “a”, the TriCoder with the ID character of “a” responds with “a123456”. The TriCoder screen goes blank and is ready for more data. When the host computer sends out a “b” polling character, TriCoder “b” responds with a “b” only (its operator is at lunch and has recorded no data). TriCoder “b” then clears its screen and is ready for data. The host software reads the transmitted data from the serial port and processes it according to your needs. The software can tell which TriCoder transmitted which piece of data by the ID character preceding the data. If you don’t care what belongs to what, the ID can be discarded. The computer and TriCoders poll and respond very quickly. People using the TriCoders are seldom conscious of any delay due to polling. The TriCoder Utilities diskette contains a basic program that polls and differentiates between data from three TriCoders that have been assigned ID characters of “a”,”b”, and ”c”.

Polling with “Host Response Accepted” Host Response Accepted is one of the protocols used with Polling. Host Response Accepted allows the TriCoder to act on data received from the R-1

Page 229

host computer. The host can send data to the TriCoder to control the beeper, display data on the TriCoder screen or broadcast a voice message. If you are using the Host Response Accepted Protocol setup option, observe the following rules: 1.

To prevent conflict between ID characters and data characters, the displayable data characters must be limited to ASCII 3295. In other words, no lower case letters are permissible.

2.

ID characters must be ASCII 96-127.

3.

A displayable prompt must be terminated by a CR unless you are sending TriCoder beeper control characters BEL, DC2, or nnDC4 (where nn is the voice message number). The beeper control characters are the termination for the prompt instead of a CR. A displayable prompt can also be a single character of CR, BEL, DC2, or nnDC4.

4.

In order to prevent the loss of a message from the host, the TriCoder locks out scanning or keyboard data entry until it receives a valid prompt from the host. The Tricoder displays the following message until it receives the prompt: WAITING ON PMPT If you want to change anything (including scanning the Setup Menu) without receiving the expected prompt from the host, you must first press the CLEAR key on the TriCoder keypad.

Polling with ACK/NAK The Polled with ACK/NAK option allows for greater data accuracy by using ACK/NAK protocol while polling. The TriCoder appends two checksum characters upon transmission of its data. The host computer receives this data, calculates the checksum then compares it to the checksums transmitted by the TriCoder. If they are the same, the host sends an ACK (ASCII 6). If they are different, the host sends a NAK (ASCII 21). If the TriCoder receives 10 NAK's in a row, it suspends operation. Sometimes it is desirable to know whether the TriCoder is "waiting on a poll" or "waiting on an ACK/NAK". A setup parameter is available that displays either the message WAITING ON POLL or WAIT ON ACK/NAK, depending on which condition is present. This feature is activated through the bar coded TriCoder Setup Menu by scanning Terminator Character, then A. To get rid of the extra messages, scan B. For more information on Polling with ACK/NAK and a sample program (BASIC), see the TriCoder Utilities disk.

R-2

Page 230

Appendix S

Modem Uploads Data collected in the TriCoder can be uploaded to a host via a Hayes-compatible modem. Either the host or the TriCoder can initiate the upload by dialing and establishing the connection. Modem communication is simple on the TriCoder side – it is the host application that can be difficult. Only someone experienced with modem communications in general and has a good understanding of their host application should attempt this type of uploading.

Successful modem communications Cabling can be the deciding factor in your success or failure to upload via modem. Getting your cables from us can help to eliminate the possibility that your cabling is causing a problem. The F32A and F46B are specially wired for modems; DSR is cut and RTS is jumpered to CTS to defeat the "RTS/CTS enabled" feature on some modems. Portable modems often require the DTR line to be forced high. The top jumper on the TriCoder circuit board can be set from its default setting of NC to H. Separate the halves of the TriCoder (by removing the four recessed screws on the back of the Tricoder) and locate the top jumper above the EPROM (labeled with a COPYRIGHT MESSAGE) on the left edge of the board. Move the top jumper from NC setting to the H side to force DTR to always be high. See the diagram in Appendix B, Firmware and Model Upgrades for a picture of the TriCoder circuit board.

Dial-up by TriCoder to Host Dial-up to a host by the TriCoder is fairly simple as long as you make sure that the TriCoder is configured properly. XMODEM is the protocol of choice but Polled with ACK/NAK can be used also. Using XMODEM with common applications such as Procomm and Windows' Hyperterminal is a popular choice for modem uploads.

Configuring the TriCoder… To get to the host through an external modem, the TriCoder needs to dial the receiving computer. Use the Dialing String parameter (which is limited to use with only the “Polling with ACK/NAK” or XMODEM protocols) on the Setup Menu. The Dialing String parameter is specified by scanning the following bar codes on the Setup Menu: 1. Start Setup 2. Dialing String 3. Up to 24 Characters scanned from the Full ASCII Menu, the last character must NOT be a CR 4. SET 5. End Setup

S-1