Page 191

This page is a scan with no text; see it in the PDF.

Page 192

Appendix F

Jumpers, Switches, and Adjustments To get to the Laser Decode Switch, you open the battery compartment and look for the switch on the visible board edge. Refer to the below diagram:

The switch must be on the W setting for the older "switch wands" to work. The W setting also allows lasers and CCDs to work, but the decode light (green light turning on for 3 seconds to signify a “good read”) will not come on unless the switch is moved to L. To do any of the following operations: 1. 2. 3. 4. 5. 6.

To change the lithium battery, adjust the headphone volume, set the TriCoder to recharge batteries with the 5v power supply plugged in, force DTR to high, to change from Serial to Keyboard Wedge, or to change Keyboard Wedge to Serial, you must remove the four screws from the back of the TriCoder using a Phillips head screw driver. Open the case and lay it out as shown on the following page:

F-1

Page 193

The Battery Recharge Jumper is shipped disabled. If you want to use rechargeable batteries and charge them in the TriCoder using the 5V power adapter shipped with the TriCoder, you need to place the jumper so that it covers both pins (JP3). When you use rechargeable batteries, you need to change the Speaker/Batteries setting (See Setup) to 3;if you use rechargeables with the Speaker/Batteries setting at 2, you will experience difficulties as the batteries run down because the TriCoder firmware will assume the longer life of alkalines.

F-2

Page 194

Appendix G

USB Driver Installation Recovery The USB TriCoder uses two separate USB “drivers”: The HID driver provided with Windows and the TRICODERUSB High Speed transfer driver provided with the TriCoder. Which driver is active depends on the operating mode of the TriCoder. Driver installation is initiated when the TriCoder device (HID or High Speed) attempts to attach to the host and the driver is not present (or incorrectly installed) on the host PC.

Incorrect driver installation is unlikely to happen; however: High Speed driver installation can be cancelled by the user and the High Speed USB upload in the TriCoder will not function. The High Speed driver installation is re-initiated next time the TriCoder is attached either before or after a Windows restart (depending on the version of Windows). Recovery from an error in installing the High Speed driver is at worst rebooting the PC and re-attaching the TriCoder to redo the driver installation. HID driver installation is usually automatic: windows pop up indicating the new device and then disappear on their own and you’re done. In some situations, the required files for the HID driver are not all found on the computer and the user is prompted for their Windows CD. If the user cancels the HID driver installation at this point, the HID mode TriCoder will not function properly and Windows does not automatically initiate a re-install as it does with the High Speed driver. Control panel utilities (varies with operating system) are required to re-install the HID driver.

Resolving incomplete, aborted, or incorrect HIGH SPEED driver installation This driver is provided with the TriCoder (included on the Utilities CD). Restarting Windows and re-attaching TriCoder will often re-initiate driver installation; if so, just follow the instructions and this time point the installer to the TriCoder Utilities CD, (or if you have downloaded the drivers, to the folder where you saved the download). Assuming the drivers was partially installed, you will have to update the driver manually following the below procedures:

Manually Updating Tricoder High Speed USB Driver on Windows XP 1.

Plug the Tricoder into the computer's USB port and turn it on. Make sure it is in High Speed mode, (go to the Data Collection? Y/N prompt).

2.

In Windows, go to: Start | Control Panel.

3.

If you are set for "Classic" view, double-click the "System" icon. If G-1

Page 195

set for "Category" view, click "Performance and Maintenance" then click "System". 4.

Click the Device Manager option in the Hardware tab.

5.

Now select the View "Devices By Type" option in the View menu.

6.

Click the "+" sign next to "Universal Serial Bus Controllers".

7.

Right-Click on the TriCoderUSB (a future version will be TriCoderHCUSB) icon and select "Properties".

8.

Click the Update Driver button in the Driver tab.

9.

In DriverWizard: Select "Install from a List or Specific Location" and click on the Next button.

10. Select "Don't Search. I will choose the driver to install." option by clicking on the appropriate radio button. 11. Click the Next button. 12. Check the "Have Disk" button. 13. In the "Install from Disk" dialog, click the browse button and select the Worth Data Utilities CD ROM or the directory where you unpacked the files downloaded from www.barcodehq.com. 14. Choose the one "trcdr.inf" (a future version will be "trcdrhc.inf") file and click "Open" 15. When you get back to the "Install from Disk" dialog, click "OK". 16. Click the Next button. 17. Click the Finish button. 18. Reboot.

Manually Updating Tricoder High Speed USB Driver on Windows 2000 1.

Plug the Tricoder into the computer's USB port and turn it on. Make sure it is in High Speed mode, (go to the Data Collection? Y/N prompt).

2.

In Windows, go to: Start | Settings | Control Panel | System.

3.

Click the Device Manager option in the Hardware tab.

4.

Now select the View Devices By Type option in the View menu (should be the default).

5.

Click the "+" sign next to "Universal Serial Bus Controllers"

6.

Right-click on "TriCoder" and select "Properties"

7.

Select the "Driver" tab and click "Update Driver"

G-2

Page 196

8.

Click the "Next" button in the Device Driver Wizard

9.

Select "Search for a suitable driver for my device (recommended)." and click "Next"

10. Select "Specify a location" and click "Next" 11. Browse to the Worth Data Utilities CD ROM of the folder where you unpacked files downloaded from www.barcodehq.com and click "OK" 12. Choose "Install one of the other drivers" at the bottom of the dialog and click "Next" 13. In the next dialog, choose "TriCoderUSB", (NOT "TRICODERUSB" which is the old driver), (future will be TriCoderHCUSB) and click "Next" 14. When it asks you to insert disk, click "OK" 15. Browse to the directory where you unpacked the files and click "OK" 16. Click "Finish"

Manually Updating Tricoder USB Driver on Windows 98/Me 1.

Plug the Tricoder into the computer's USB port and turn it on. Make sure it is in High Speed mode, (go to the Data Collection? Y/N prompt).

2.

In Windows, go to: Start | Settings | Control Panel | System.

3.

Now select the View Devices By Connection option.

4.

For USB devices, navigate to Standard PC | PCI bus | PCI To USB Universal Host Controller | USB Root Hub | TricoderUSB, (future will be TriCoderHCUSB).

5.

Select Properties.

6.

Click the Update Driver button in the Driver tab.

7.

Click the Next button.

8.

Check the Only Specify A Location check-box.

9.

Click the Next button.

10. In the input box that is displayed, enter the path to the Worth Data Utilities CD or the folder where the downloaded driver files have been extracted. 11. Click the OK button. 12. Click the Next button. 13. Click the Finish button. 14. Reboot. G-3

Page 197

Resolving incomplete, aborted or incorrect HID driver installation This driver is provided with Windows. Most recent versions of Windows include necessary files in the installed Windows folder so driver installation is easy if not automatic. It is possible for the user to cancel the HID driver installation before it is completed and this results in a problem. Restarting Windows and re-attaching the TriCoder does NOT initiate a reinstallation. The TriCoder may hang with the message: USB enumeration Please Wait… when attempting to re-attach, or it may appear to attach correctly but not operate in keyboard mode. In either case, the user must physically attach the TriCoder, turn it on and press a key on the TriCoder to get past the startup prompt. If the TriCoder was initially configured as “High Speed USB” then set it for “Non-Portable mode” to force HID keyboard enumeration. The user must then go into the device management utility in Windows. Location and operation of the device management utility is different depending on the version of Windows:

Windows XP: 1. Go to the Start menu. 2. Select Control Panel. 3. Switch to "Classic View" if in "Category View" 4. Select "System". 5. Select "Hardware" tab. 6. Select "Device Manager" 7. Double Click on the" Human Interface Devices" 8. Locate the USB Human Interface Device with a "!" in the icon. 9. Click on Update Driver 10. Follow instructions. If XP fails to find the driver on the computer's hard disk, you may have to insert and point to the original Windows XP CD to complete the installation. 11. Click "Finish"

Win98/ME: 1. 2. 3. 4. 5. 6. 7. 8.

Go to the "Start" menu. Go to "Settings". Select "Control Panel". Go to "System". Click on the "Device Manager" tab. Double Click on the "USB Human Interface Devices" (it may be titled TriCoder HID Keyboard instead). Now click on the "Reinstall Driver" button. Follow directions. If the installer cannot find the right driver file on your hard disk, you may have to insert the original Windows 98 G-4

Page 198

9.

CD and point to it to complete the installation. Click "Finish".

Win2000: 1.

Log on as Administrator and open the “Administrative Tools” folder in your Control Panel.

2.

Run the “Computer Management” utility.

3.

Select the “Tree” tab on the left panel

4.

Find the “Device Manager” entry under “System Tools” and click on it. The right panel will display current devices.

5.

Problem devices will be identified with an “!” icon. Find either the “HID Keyboard Device” under Keyboards or the “USB Human Interface Device” under Human Interface Devices and double-click on one of those entries.

6.

Now select the “Driver” tab at the top of the window and click on the “Update Driver” button. Follow the prompts to re-install the HID driver.

G-5

Page 199

This page is a scan with no text; see it in the PDF.

Page 200

Appendix H

Specifications for Code 39 Code 39 (or Code 3 of 9) is the de facto standard of non-retail American industry. It is widely used in the automotive industry (AIAG specifications) as well as in government and military applications (LOGMARS specifications). Code 39 is flexible, features a large character set, variable data length and density, and bi-directional readability. Code 39 is extremely accurate; substitution errors are almost nonexistent. Its character set consists of numbers 0 through 9, upper case A-Z, and characters Space, $, %. / + and -. The name "Code 39" comes from both the fact that its character set originally contained 39 characters (it now has 43) and from its structure. Each character is formed of three wide and six narrow elements, made up of five bars and four spaces. Code 39's density can vary from a low of .75 characters per inch (cpi) to a high of 9.4 cpi. There should be a ¼" "quiet zone" (white space) to the left and right of the bar code. Code 39 uses an asterisk (*) as a start and stop character. This character must precede and follow the data in the bar code. The TriCoder gives you the option of transmitting or not transmitting these characters when the bar code is read. Exact specifications for Code 39 and other bar code symbologies can be obtained from ANSI at the address below: American National Standards Institute Customer Service nd 11 West 42 St. New York, NY 10036 http://web.ansi.org document ANSI/AIM BC1-1995 Code 39 has several advanced features and functions that are discussed further in this appendix.

H-1