The text of a manual · part 6 of 7
WDP Manual, pages 51 to 60
Pages 51 to 60 of 67
The original document is the PDF (546 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Worth P22 and Worth LI-50
Page 51
Appendix F
MSI/Plessey Specifications Plessey is a variable length numeric only bar code. MSI Bar Code is a variable length, numeric-only code with an automatically appended Modulus 10 check digit. MSI is sometimes called Modified Plessey Code. If the user specifies an additional check digit, the MSI code can be 14 digits long, otherwise it has a maximum length of 13 characters. This is how the MSI check digit(s) are calculated: The MSI Mod 10 check digit is calculated as follows: The example bar code data is: 82345 1. Form a number from the odd positions, starting in the units position. 835 2. Multiply the new number by 2 (835) x 2 = 1670 3. Add the digits of product 1 + 6 + 7 + 0 = 14 4. Add the even digits of the original number to the result in 3 2 + 4 + 14 = 20 5. Subtract the result from the next highest multiple of 10 20 - 20 = 0 6. New Check Digit 0 7. Data with check digit is: 823450
F-1
Page 52
The MSI Mod 11 check digit is calculated as follows: The example bar code data is: 943457842 1. Assign a checking factor to each number, starting with the units position of the number (in this example, the 2) up to the highest order position (the 9). Use checking factors of: 2,3,4,5,6,7,2,3,4,5,6,7... 2. Multiply the checking factor with its assigned number and add the products: 4 + 12 + 32 + 35 + 30 + 28 + 6 + 12 + 36 = 195 3. Divide the sum by 11 195/11 = 17 remainder 8 4. Subtract remainder from 11 11 - 8 = 3 5. New Check Digit 3 (If the remainder is 10, no check digit is added.)
6. Data with check digit is: 943457823
F-2
Page 53
Appendix G
Code 93 Specifications Code 93 is variable length, continuous, bi-directional, compact code. Code 93 is an alphanumeric bar code which consists of 43 data characters (0-9,A-Z,$/+% .- and Space), 4 control characters, and a unique start/stop character. The entire set of 128 ASCII characters is represented in Code 93 using combinations of control characters and data characters. / and + . Full ASCII 93 is created by The control characters are $ % pairing these control characters with normal data characters. It is almost identical to the pairings for Code 39; Code 39 uses $M to produce a Carriage Return (ASCII 13) character -- Code 93 uses $ M to produce the Carriage Return.
Code 93's two built-in check digits greatly minimize the possibility of reader substitution errors. These check digits are never transmitted by the bar code reader. Code 93's Start and Stop characters are also never transmitted. If you have not decided which bar code type to use for your application and are considering using Code 93, while we agree that Code 93 is an excellent code, we believe that Code 128 is generally preferable because: 1. Code 93 does not have the numeric compression capability that 128 does, and 2. Code 93 requires pairings to make all Full ASCII characters while 128 does not.
G-1
Page 54
Appendix H
ASCII Code Equivalent Table The 128 ASCII codes and their 3 digit decimal equivalents are detailed in the table below. Char hex
ASCII
Char hex
ASCII
Char hex
ASCII
Char hex
ASCII
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E OF 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031
SP ! “ # $ % & ‘ ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 059 060 061 062 063
@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082 083 084 085 086 087 088 089 090 091 092 093 094 095
‘ a b c d e f g h i j k l m n o p q r s t u v w x y z } | } ~ DEL
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
096 097 098 099 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
H-1
Page 55
Appendix I
Resolving USB Installation Issues The USB HID (Human Interface Device) driver is provided with Windows®. Most recent versions of Windows include necessary files in the installed Windows folder so driver installation is easy if not automatic. It is possible for the user to cancel the HID driver installation before it is completed and this results in a problem. Restarting Windows does NOT initiate a re-installation; the user must go into the device management utility in Windows. Location and operation of the device management utility is different depending on the version of Windows: Windows® XP: 1. Go to the Start menu. 2. Select Control Panel. 3. Switch to Classic View if you are in Category View 4. Select System. 5. Select Hardware tab. 6. Select Device Manager 7. Double Click on Human Interface Devices 8. Locate the USB Human Interface Device with a ! in the icon. 9. Click on Update Driver 10. Follow instructions. If Windows® XP fails to find the driver on the computer's hard disk, you may have to insert and point to the original Windows CD to complete the installation. 11. Click Finish Windows® 98SE/ME: 1. Go to the Start menu. 2. Go to Settings. 3. Select Control Panel. 4. Go to System. 5. Click on the Device Manager tab. 6. Double Click on the USB Human Interface Devices 7. Click on the Reinstall Driver button. 8. Follow directions. If the installer cannot find the right driver file on your hard disk, you may have to insert the original Windows 98SE CD and point to it to complete the installation. 9. Click Finish. Windows® 2000: 1. Log on as Administrator and open the Administrative Tools folder in your Control Panel. I-1
Page 56
2. Run the Computer Management utility. 3. Select the Tree tab on the left panel 4. Find the Device Manager entry under System Tools and click on it. The right panel will display current devices. 5. Problem devices will be identified with an ! icon. Find either the HID Keyboard Device under Keyboards or the USB Human Interface Device under Human Interface Devices and double-click on one of those entries. 6. Select the Driver tab at the top of the window and click on the Update Driver button. Follow the prompts to re-install the HID driver. Windows® Vista®: 1. Go to the Start Menu. 2. Select Control Panel. 3. Switch to Classic View if you are in Category View 4. Select System. 5. Select Device Manager task. 6. Double Click on Human Interface Devices 7. Locate the USB Human Interface Device with a "!" in the icon. 8. Click on Update Driver in Action menu 9. Follow instructions. If Windows® Vista® fails to find the driver on the computer's hard disk, you may have to insert and point to the original Windows CD to complete the installation. 11.Click Finish Note: In order to install new hardware in Vista® you may need to turn off the UAC (UserAccount Control). UAC is turned off using the User Account icon. UAC is turned on using the Sercurity Center icon.
I-2
Page 57
Appendix J
WDP P22 Board Diagram Typically, there will be no reason to have to open the WDP P22 decoder case. But, if you have ordered your P22 to replace an older WDP reader and you are using the same wand as before, you may need to change a switch on the WDP P22 circuit board. If you are having these symptoms and conditions with your P22 reader, you need to open the case and change the switch: • You are connected to the USB port • Using an older wand from a previous reader • Your wand has a dim light instead of the the bright red light at the tip • Your reader beeps on power up but does not beep when you try to scan a bar code To open the reader case: unscrew tilt screw and pull up to open lid
Move the S1 switch from Laser to Wand:
Power
USB
Y Cable
P22 Assy: 1042-001 Rev 2 Worth Data Inc.
S1 LASER WAND
3004
Scanner
Magstripe
J-1 open
Page 58
Page 59
Appendix K
WDP Setup Menu To change a setting using the WDP Setup Menu: • Scan START SETUP to enter setup mode • Scan the parameter you want to change (i.e. Code 3 of 9) • Choose the setting you want to change and scan the corresponding letter or number from the Barpad Table (0-9, A-F) • When all changes have been made, scan END SETUP • For Preamble and Postamble settings, use the FULL ASCII MENU • * indicates default settings Start Setup
End Setup
*/+/* Code 3 of 9
*/A/*
*/-/* UPC/EAN
*/B/*
* 0 Enable Code 39 1 Disable Code 39 * 2 Enable Full ASCII Code 39 3 Disable Full ASCII Code 39 * 4 Enable Accumulate Mode 5 Disable Accumulate Mode 6 Transmit Start/Stop characters * 7 Don’t transmit Start/Stop characters 8 Enable Mod 43 Check Character * 9 Disable Mod 43 Check Character A Transmit Mod 43 Check Character * B Don’t transmit Mod 43 Check Character C Caps Lock ON * D Caps Lock OFF
* 0 Enable UPC/EAN 1 Disable UPC/EAN 2 Enable Supplements * 3 Disable Supplements * 4 Transmit UPC-A NSC 5 Don’t transmit UPC-A NSC * 6 Transmit UPC-A Check Digit 7 Don’t transmit UPC-A Check Digit 8 Transmit UPC-E NSC & EAN-8 Flag Ch * 9 Don’t transmit UPC-E NSC & EAN-8 Flag Ch A Transmit UPC-E & EAN-8 Check digit * B Don’t transmit UPC-E & EAN-8 Check digit * C UPC-E Compressed transmission D UPC-E Expanded transmission * E EAN-8 observes 9 & A above F EAN-8 is forced to transmit 8 digits always
2 of 5 Code
2 of 5 Length
*/C/*
*/5/*
0 Enable I 2 of 5 * 1 Disable I 2 of 5 2 Enable check digit * 3 Disable check digit 4 Transmit check digit * 5 Don’t transmit check digit 6 Enable 2 of 5 * 7 Disable 2 of 5
Scan 2 digit length (default is 06)
RSS-14
*/%/* 0 Disable RSS-14 1 Standard 14 digits
K-1
2 14 + Identifiers 3 14 + UCC-128 Emulation
Page 60
Start Setup
End Setup
*/+/* Code 93
*/W/*
*/-/* Code 128
*/S/*
0 Enable Code 93 * 1 Disable Code 93 2 Enable Full ASCII Code 93 * 3 Disable Full ASCII Code 93
0 Disable 128 * 1 Enable 128 2 Disable UCC/EAN-128 * 3 Enable UCC/EAN-128
Codabar
MSI/Plessey
*/D/*
*/R/*
0 Enable Codabar * 1 Disable Codabar 2 Enable CLSI Codabar * 3 Disable CLSI Codabar * 4 Suppress start/stop characters 5 Enable start/stop characters
* 0 Disable MSI 1 Enable MSI 1 Mod 10 check digit 2 Enable MSI 2 Mod 10 check digits 3 Enable MSI Mod 11/10 check digits * 4 Transmit no check digit 5 Transmit 1 check digit 6 Transmit 2 check digits 7 Enable Plessey 8 Enable Labelcode 5 9 Enable Labelcode 4
Computer Interface
Data Transmission Timing
*/M/*
*/N/*
* 1 PC Keyboard and USB Wedge Saver 3 PC Learned Timing
* 0 None 1 Short 2 Short Medium 3 Medium 4 Long
Terminator Character
Beep Tone
*/H/*
*/L/*
* 0 Enter 1 None 2 Tab
0 Lowest 1 Low * 2 Medium
Characters
Keyboard Country
*.1.*
Scan up to 8 sets of hex characters to reassign and delete characters in the bar code output. Scan SET when completed.
This adjusts for differences in BIOS and clock speeds
3 High 4 Highest 5 No Beep Tone
*.4.*
05 Danish * 00 USA 01 French 06 Dutch 02 German 07 Italian 03 Belgian 08 Latin Amer. 04 Fr. Canadian 09 Norwegian
K-2
10 Portuguese 11 Spanish 12 Swedish 13 Swiss 14 U.K.