Page 31

Chapter 4

Special Features Function and Control Key Support The WDP Reader can also transmit key sequences for function, control, alt (command and option keys on Macs), cursor and shift keys, for ease of use with the many software packages using these keys for menus or commands. These “keystrokes” are scanned in to your Preamble or Postamble in order to add them to every scan from your reader. For this to work, you must have Full ASCII Code 39 enabled on your reader (this is the default setting). To use them in your Preamble or Postamble, see pages 2-8 and 2-9 for details. Scan the corresponding bar code from the Full ASCII menu to emulate the chosen key. PC Key

Mac Key

Full ASCII Menu Bar Code

PC Key

Mac Key

Full ASCII Menu Bar Code

F1 F2 F3 F4 F5 F6 F7 F8 Numpad 5* Enter F9 F10 Del Insert

F1 F2 F3 F4 F5 F6 F7 F8 Enter Return F9 Cmnd On Del Cmnd Off

SOH (f1) STX (f2) ETX (f3) EOT (f4) ENQ (f5) ACK (f6) BEL (f7) SO (f8) LF CR SI (f9) DLE (f10) DC1 (Del) DC2 (Ins)

Left Arrow* Rt Arrow* Dn Arrow* Up Arrow* Pg Up* Pg Dn* Home* End* Shift ON Shift OFF Control On Control Off Alt On Alt Off

Left Arrow+ DC3 ( ) Rt Arrow+ DC4 (➝) Dn Arrow+ NAK ( ) Up Arrow+ SYN ( ) Pg Up+ VT (Pg Up) Pg Down+ FF (Pg Dn) Home+ ETB (Home) End+ CAN (End) ➝

➝

➝

Shift ON EM (Shift ON) Shift OFF SUB (Shift OFF) Control On+ FS (Ctrl ON) Control Off+ GS (Ctrl OFF) Option On RS (Alt ON) Option Off US (Alt OFF)

* refers to the keys on the Number pad on the far right side of a PC keyboard. To emulate any of the keys above, scan the appropriate bar code from the FULL ASCII MENU. For example, to emulate the F5 key, scan the ENQ bar code. + these keys apply to Mac ADB interface ONLY. For Mac USB, you must use the keys in the table below.

PC Key

Mac Key

Full ASCII Menu Bar Codes

PC Key

Insert Delete End Down Arrow Page Down Left Arrow Line Feed

Ins del end down arrow page down left arrow Line Feed

NUL NUL NUL NUL NUL NUL NUL

Right Arrow right arrow NUL Home home NUL Up Arrow up arrow NUL Page Up page up NUL Windows ON control ON NUL Windows OFF control OFF NUL ENTER (num) ENTER (num) NUL

0 . (period) 1 2 3 4 5

Mac Key

Full ASCII Menu Bar Codes 6 7 8 9 C D E

This chart corresponds to the small center section of keys between the main letter keys and the Numeric keypad on the right of the keyboard and requires you to scan two bar codes from the FULL ASCII MENU - the NULL bar code and then the appropriate character. For example, to emulate the END key, scan the NULL bar code, then the 1 bar code.

Function keys F1 through F10, and numeric-pad keys Function keys F1 through F10, and numeric-pad keys (such as Left Arrow and Del), are encoded by a single control character as shown in the table above. Simply scan the correct bar code from the FULL ASCII MENU. 4-1

Page 32

For example, if the WDP reads the bar code SOH (ASCII 001 -- a control-A) from the FULL ASCII MENU, it will transmit an F1 key sequence to your computer. Function keys F11 and F12 Function keys F11 and F12 require two bar codes to be scanned to make these functions keys. The F11 key is created by combining the Null and SOH. The F12 key is created by combining the Null and the STX . Shift, Ctrl and Alt keys Shift, Ctrl and Alt keys require three sequences 1) The ON code generated when the Shift, Ctrl or Alt key is pressed. 2) The other key to be used in conjunction with the Shift, Ctrl or Alt key. 3) The OFF code generated when the Shift, Ctrl or Alt key is released. For example, to properly emulate the keystrokes for Ctrl-C, you would scan the bar code for Control ON (FS), C, and Control OFF (GS). Windows Key The Windows key on a Windows keyboard is transmitted by scanning 4 bar codes - NULL and C for Windows On (pressing down) and NULL and D for Windows Off (releasing the key). Macintosh Command and Option Keys on USB When you have a WDP Reader attached to a Macintosh Computer's USB port, to emulate the Command key, use the Windows key ON/OFF bar codes NULL, C (Command ON) and NULL, D (Command OFF) For the Option Key ON/OFF use RS (Option On) and US (Option Off ). If you have an older Worth Data Reader (before 6/99), you can also imitate the Command Key by keycodes in the Preamble/Postamble. To transmit Command N would be:`E01F'N`E0F01F' Transmitting any ASCII character using its 3-digit ASCII code You can also transmit any ASCII character from 000 to 255 by emulating the PC technique of typing a character's ASCII number on the numeric pad while holding down the Alt key. For example, to transmit ASCII 250, you would scan the bar codes for: Keystroke

Full ASCII Menu Bar Code

Alt ON RS Ins (0 on the numeric pad) DC2 Down Arrow (2 on the numeric pad) NAK Numpad 5 LF Ins (0 on the numeric pad) DC2 Alt OFF US

4-2

Page 33

Accumulate Mode Accumulate Mode is an option (which can be enabled or disabled using the Reader Setup Menu's Code 39 section) allowing the reader to accumulate multiple bar codes in its buffer, then transmit them to the computer as if they had been a single bar code. This is useful for entering quantities and other variable data. It works with Code 39 only, and can't be used with a check digit. When the reader reads a bar code with a leading space, it beeps and buffers the data without transmission. It continues to read and buffer bar codes (up to 40 characters) until it reads a bar code without a leading space. Then the entire buffer (including that last code) is transmitted as one long bar code. A bar code of a double minus (--) sign clears the buffer. Scanning a backspace code ($H) backspaces in Full ASCII mode. A handy code for Enter (as seen on the "Barpad" below) is a Start/Stop only. (No data.) If you don’t have a Terminator Character programmed, you will have to scan a CR (see the Full ASCII menu) instead of the Enter bar code shown below. This numeric "Barpad" illustrates Accumulate Mode. Scan 5, 3, 8, and Enter. The reader transmits a single message of 538.

0

1

2

3

4

5

6

7

8

9

Clear

Backspace

Enter 4-3

Page 34

This page is a scan with no text; see it in the PDF.

Page 35

Chapter 5

Troubleshooting A reader installed in Wedge mode doesn't beep three times when you power up your system, or the keyboard locks up, or you get a "keyboard error" or "301" message. •

Check the cable connections to make sure everything is plugged in securely. With a PC, make sure the keyboard cable is plugged into the keyboard port rather than the mouse port.

•

If, after checking the connections, you still have a problem, your computer and keyboard combination probably doesn't have enough left-over power to drive the bar code reader also. Disconnect the scanner from the WDP Reader and reboot your system. If the system boots correctly when the scanner is not attached, you solve the problem by ordering a 5-volt external power supply (part number F10) for your P22 WDP.

•

If the system still doesn't boot correctly with the scanner disconnected, a Worth Data regulated power supply (don't use someone else's power supply or you will damage the reader)- will probably still correct the problem. If you are using a USB reader and there many devices, you may need either a power supply on the WDP (P22 only), or you may need a powered USB hub device.

Using USB, the reader initializes and then turns off. • There is not enough power available on the USB port. If you are connected to a USB port on the keyboard, try connecting to a USB port on the CPU itself. You may need to buy a powered USB Hub with its own power supply - you can pick them up inexpensively at your nearest computer store. Using USB, the reader powers up and beeps when a bar code is scanned but no data is transmitted. • Go to the Control Panel, then to System, then Device Manager. Check your HID devices. Right click on the HID device to see if the device is working properly. If it is not, click on Driver and proceed to reinstall the driver. See Appendix I for details for your operating system. The reader won't beep when reading bar codes •

Recheck all the connections using the installation section as a guide. Try reading a known good bar code - the test label on page 3-2, following the steps for scanning in Chapter 3; Scanners and Scanning Technique. If you're trying to read Code 39 bar codes with leading spaces (such as the Barpad on page 4-3) and have enabled Accumulate Mode, those bar codes will not be transmitted to your computer until you read a bar code without a leading space. Try reading the Test Label on page 3-2 as an example of a known good label.

•

If the read failure is on Interleaved 2 of 5 codes, make sure the data length is the same that you selected on the Reader Setup Menu. Be sure you don't 5-1

Page 36

have the check digit enabled for Code 39 or Interleaved 2 of 5 if you're trying to read data without check digits. • If you are using a laser scanner (especially a long-range laser), you may need to increase the length of time the scanner attempts to read. The default is a 2-second beam. To change to a 4-second beam, scan Start Setup, 2 of 5 Code, F, then End Setup. Scanning E instead of F sets the beam back to 2 seconds. • If you are using a P22 decoder connected the a USB port with an older wand scanner, you need to open the P22 decoder and change the S1 switch to “wand” instead of “laser”. Typical symptoms are a dim wand light and no reading. See Appendix J for a diagram. Extra characters at the beginning or end of your bar code data • Clear the Preamble and Postamble. • Make sure you haven't enabled transmission of any start/stop characters, checksums, leading digits or terminator characters that you don't want transmitted. For UPC-E, select Compressed transmission if you don't want it padded with extra zeros. The reader transmits incorrect data to the screen Reread page 2-7 and make sure you chose the proper Computer Interface. • If part of the data is correct and part missing, you need to tell the WDP

Reader to transmit data at a different rate. First try Learned Timing on page 2-7, and if that doesn't work, resort to changing Data Transmission Timing on page 2-10 (Keyboard Interface ONLY). • If the reader is transmitting punctuation characters (!@#$%^&*) when reading numeric bar codes, or transmitting letters in the wrong (upper/ lower) case, you may have a Num Lock, Caps Lock, shift or timing problem. Check your keyboard to see if the Num Lock or Caps Lock keys have been activated. Finally, try "learned timing" (See Page 2-7) or changing your Data Transmission Timing (See page 2-10). • If you're using Code 39, read page 2-4 to see if you've set Caps Lock properly for your application. If your Code 39 bar codes include punctuation characters %, $, / or +, the reader is seeing them as part of Full-ASCII Code 39 sequences. Using the Reader Setup Menu, disable Full ASCII Code 39. • If you are using a laser scanner and are reading poorly printed codes or scanning through a windshield, make sure “double-scan checking” is enabled (It is the default setting). “Double-scan checking” does take longer (it forces the reader to keep scanning until it gets two identical reads) but will eliminate mis-reads. “Double-scan checking” is set under the Code 39 setup parameter by scanning Start Setup, Code 39, E, then End Setup. Scanning F instead of E will disable this option.

5-2

Page 37

Poor read rate •

Try reading the test label on page 3-2 (following the scanning instructions in Chapter 3) as an example of a known good bar code. Examine your bar codes to make sure they have dark bars, clearly defined bars and white spaces, and a "quiet zone" of at least 1/4 inch to the left and right. If the bars are grey, or so dark that they "bleed" into the white spaces, the person or organization printing them will need to adjust the printer or get a new ribbon or toner cartridge for it.

•

Carefully follow the scanning instructions in Chapter 3 when reading any and all bar codes. As straightforward as scanning may seem, many people who call Worth Data with a complaint about poor read rate are simply not doing it correctly.

•

If you're using an infrared bar code wand, be sure the bar codes you're trying to read were printed with infrared-quality ink. Make sure you're using the right type of wand for the type of bar codes you're trying to read.

•

Pry the wand tip off; clean the inside with a soft, lint-free cloth. Carefully blow off any debris from the red plastic lens.

•

Erratic or low read rates can also result with systems that supply unusually low current or voltage to the keyboard. To test for this, turn your system off, disconnect the keyboard from the "Y" cable, and turn it back on. Then try reading the same bar codes. The system will probably be in a keyboard error state and not display the bar code data on the screen, but all you're interested in is listening for the beeps that signify good reads. If the WDP Reader has a much higher read rate without the keyboard attached, you can probably solve the problem by using a Worth Data regulated 5-volt external power supply (F10).

5-volt power adapters for keyboard wedge installation: The 5-volt adapter (F10 for 110V, F11 for 220V, F14 for UK 220V, and F13 for Australia 240V) is used to power the WDPs with separate decoder box configurations (P22) where the computer supplies unusually-low voltage or current to the keyboard.

MODEL:AUT-05-1000 INPUT: 100V-240V~50-50Hz/0.3A OUTPUT: 5V- - - 1000mA C

91-58156 US RATING AC 100V 50/60Hz 0.3A 10-20VA

LISTED 7T73 E153158 CLASS II ITE POWER SUPPLY

19739

CAUTION: DO NOT OPEN RISK OF ELECTRICAL SHOCK

ATTENTION: RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR

Made in Taiwan

9950

Don't use anything but a Worth Data power supply or you will probably damage the reader. The Worth Data power supply is regulated and has a specific polarity. Almost all other power supplies are unregulated and will damage the WDP is used. Just because the connector fits, don't use it. If your power supply does not display this label, it does not belong to your WDP reader. Only plug in a power supply that comes from Worth Data and displays this label. 5-3

Page 38

This page is a scan with no text; see it in the PDF.

Page 39

Appendix A

Specifications for Code 39 Code 39 (or Code 3 of 9) is the de facto standard of non-retail American industry. It is widely used in the automotive industry (AIAG specifications) as well as in government and military applications (LOGMARS 123ABC specifications). Code 39 is flexible, features a large character set, variable data length and density, and bi-directional readability. Code 39 is extremely accurate; substitution errors are almost nonexistent. Its character set consists of numbers 0 through 9, upper case A-Z, and characters Space, $, %. / + and -. The name "Code 39" comes from both the fact that its character set originally contained 39 characters (it now has 43) and from its structure. Each character is formed of three wide and six narrow elements, made up of five bars and four spaces. Code 39's density can vary from a low of .75 characters per inch (cpi) to a high of 9.4 cpi. There should be a ¼" "quiet zone" (white space) to the left and right of the bar code. Code 39 uses an asterisk (*) as a start and stop character. This character must precede and follow the data in the bar code. The WDP gives you the option of transmitting or not transmitting these characters when the bar code is read. Exact specifications for Code 39 and other bar code symbologies can be obtained from ANSI at the address below: American National Standards Institute Customer Service 11 West 42nd St. New York, NY 10036 http://web.ansi.org document ANSI/AIM BC1-1995

A-1

Page 40

Mod 43 Check Character Standard Code 39 can be printed with a "Mod 43 Check Character". This Mod 43 check character cannot be used with Full Ascii Code 39. The check character is derived by assigning a value to each character in the data to be bar coded from the table as follows: Char 0 1 2 3 4 5 6 7 8 9

Value

Char

Value

Char

Value

Char

Value

0 1 2 3 4 5 6 7 8 9 A

B C D E F G H I J K 10

11 12 13 14 15 16 17 18 19 20 L

M N O P Q R S T U V 21

22 23 24 25 26 27 28 29 30 31 W

X Y Z . Space $ / + % 32

33 34 35 36 37 38 39 40 41 42

Here is an example to illustrate how the check character is calculated for bar code data of 123XYZ: 1. Take the sum of the values assigned to each character: 1 + 2 + 3 + 33 + 34 + 35 = 108 1

2

3

X

Y

Z

2 Divide the sum by 43: (thus the name modulus 43) 108/43 = 2 with a Remainder of 22 3. Find the character corresponding with the remainder. M (value 22) is the CHECK CHARACTER

The data becomes 123XYZM, with M added as the Mod-43 check character.

A-2