Page 11

WDP Setup Parameters Beep Tone Lowest Low Medium High Highest Turn Beeper OFF, No “Laser Good” LED Turn Beeper OFF, Yes “Laser Good” LED No Aiming Dot for LZ400-D 1 Second Aiming Dot 2 Second Aiming Dot 3 Second Aiming Dot 4 Second Aiming Dot 5 Second Aiming Dot 6 Second Aiming Dot

0 1 2 3 4 5 6 9 A B C D E F

The WDP Reader gives you a choice of five different beep pitches. The aiming dot settings are for use with an LZ400-D laser only.

Code 39 Enable Code 39 Disable Code 39 Enable Full ASCII Code 39 Disable Full ASCII Code 39 Enable Code 39 Accumulate Mode Disable Code 39 Accumulate Mode Enable Start/stop character transmission Disable Start/Stop character transmission Enable Mod 43 Check Digit Disable Mod 43 Check Digit Enable Check Digit Transmission Disable Check Digit Transmission Caps Lock ON Caps Lock OFF

0 1 2 3 4 5 6 7 8 9 A B C D

For information about Code 39, Full ASCII Code 39 and Accumulate Mode, see Appendix A. The Storage Tek variation of Code 39 is also supported any time Code 39 is enabled. Enabling Start/Stop character transmission means that the WDP Reader will transmit the * Start/Stop characters to your computer along with the data. For example, data of 1234 would be transmitted as *1234*. Most people don't need this option, but it is useful if you want your software to be able to differentiate between keyboard and bar code data. Enabling the Mod 43 Check Digit requires the units position of your data to match the calculation for the check digit explained in Appendix A. If you've enabled the check digit, enabling Check Digit transmission causes the reader to transmit the check digit to your computer along with the bar code data. 2-3

Page 12

"Caps Lock ON" means that lowercase letters read as data will be transmitted as uppercase, and uppercase as lower. Numbers, punctuation and control characters are not affected. "Caps Lock OFF" means that letters will be transmitted exactly as read.

UPC/EAN Enable UPC/EAN 0 Disable UPC/EAN 1 Enable UPC/EAN Supplements 2 Disable UPC/EAN Supplements 3 Enable transmission of UPC-A NSC and EAN-13 first two digits 4 Disable transmission of UPC-A NSC and EAN-13 first two digits 5 Enable transmission of UPC-A/EAN-13 Check Digit 6 Disable transmission of UPC-A/EAN-13 Check Digit 7 Enable transmission of UPC-E NSC and EAN-8 first digit 8 Disable transmission of UPC-E NSC and EAN-8 first digit 9 Enable transmission of UPC-E/EAN-8 Check Digit A Disable transmission of UPC-E/EAN-8 Check Digit B UPC-E Compressed C UPC-E Expanded D EAN-8 observes 9 and A above E EAN-8 if forced to transmit 8 digits F UPC-A transmitted in UPC-A format (see below) UPC-A transmitted in EAN-13 format (see below) ISBN conversion disabled (see below) ISBN conversion enabled (see below)

For general information about UPC and EAN, see Appendix E. Enabling supplements allows you to read 2 and 5-digit supplemental codes used with magazines and books. This disallows right-to-left reading of UPC/EAN codes, to assure that the supplement doesn't get skipped. This setting also allows for reading of the UCC/EAN 128 Extended Coupon Code. The Extended Coupon Code consists of a UPC(must have NSC of 5) or an EAN (NSC of 99) code along with a Code 128 supplemental code right next to it. This setting allows you to read the Code 128 supplement as long as the correct NSC characters are present in the UPC or EAN code. Enabling transmission of UPC or EAN NSC's (leading digits, 1 for UPC; 2 for EAN-13) or Check Digits means that these digits will be transmitted to your computer along with the rest of the UPC or EAN data. UPC-E Compressed Format transmits UPC-E codes as is; Expanded Format adds zeros to make them the same length as UPC-A. UPC-E can be used in either normal UPC-E format (implicit NSC of 0) or UPC-E1 format (NSC of 1). UPC-E1 settings are found in the 2 of 5 Code parameter. Setting 8 enables UPC-E1 reading while 9 disables UPC-E1 (9 is the default). It is very easy to read an EAN-13 bar code partially as UPC-E1, so don't enable UPC-E1 when reading EAN-13. 2-4

Page 13

If you wish the UPC-A data to be transmitted in EAN-13 format, (with an additional leading 0 for the USA's country code), you should scan Terminator Character and F. Scanning E, the default, sets UPC back to no country code transmitted. ISBN bar codes are EAN-13 bar codes where the first three digits are the "Bookland" country code of 978 for books and 977 for periodicals, and the following nine are the first nine digits of the ISBN.The ISBN settings are located in the Terminator Character parameter. To enable transmission of ISBN bar codes in ISBN format (the nine ISBN digits plus a new calculated mod-11 check digit), scan Terminator Character and D. Scanning C, the default, disables conversion to ISBN format.

Code 93 Enable Disable Enable Full ASCII Disable Full ASCII

0 1 2 3

For more information about Code 93, See Appendix G.

2 of 5 Code Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 check digit Disable Interleaved 2 of 5 check digit Enable check digit transmission Disable check digit transmission Enable Standard 2 of 5 Disable Standard 2 of 5 Enable UPC-E1 Disable UPC-E1

0 1 2 3 4 5 6 7 8 9

For information about Interleaved 2 of 5, see Appendix D. Enabling the check digit requires that the data’s units position (last character) match the calculation for the check digit explained in Appendix D. If you have enabled the check digit and want to transmit the check digit to the computer along with the rest of the bar code data, choose “Enable check digit transmission”. See the UPC/EAN parameter on page 2-4 for more information on UPC-E1 format.

2 of 5 Data Length Default Length

06

2 of 5 Code is so susceptible to interpreting partial scans as valid reads that the WDP Reader uses fixed-length data as a safeguard. To choose a data length, scan it as a two-digit number using the Barpad Table. For example, to select 8-digit data length, you would scan a 0 and then a 8. Because Interleaved 2 of 5 is required to be an even number of digits in length, you must use an even number. 2-5

Page 14

If you're unsure of your bar code length, temporarily set length to 00, read a bar code, and count its digits. Variable-length 2 of 5 codes are very dangerous.

Codabar Enable Codabar Disable Codabar Enable CLSI Codabar Disable CLSI Codabar Disable Start/Stop character transmission Enable Start/Stop character transmission

0 1 2 3 4 5

For information about Codabar, see Appendix B. CLSI format is a form of Codabar often used by libraries Enabling Start/Stop character transmission means that the WDP will transmit the Start and Stop characters to your computer along with the bar code data. Enable transmission if you are varying the Start and Stop characters according to label type in order to differentiate between bar code data and data from the keyboard. Most people do not need to transmit the Start/Stop characters.

Code 128 Disable Code 128 Enable Standard Code 128 Disable UCC-128/EAN-128 Enable UCC-128/EAN-128 Bar Code ID’s transmitted Bar Code ID’s not transmitted

0 1 2 3 E F

See Appendix C for details on Code 128 and UCC-128/EAN-128. Bar Code ID’s are characters assigned to each bar code type to identify that particular type of code. These Bar Code ID’s can be used to identify what type of bar code you are using when you are not sure or you want your application to differentiate between the different types. The Bar Code ID’s are assigned as follows: Bar Code

ID

Bar Code

ID

Codabar UPC-A I 2 of 5 Code 128 MSI UPC-E(0) EAN-8 Plessey LabelCode 5 a c e g j n p x z

Code 39 EAN-13 2 of 5 (standard) Code 93 magstripe data UPC-E1 (1) Storage Tek LabelCode 4 RSS-14 b d f i m o s y r

2-6

Page 15

MSI and Plessey Disable MSI and Plessey Enable MSI with 1 Mod 10 check digit Enable MSI with 2 Mod 10 check digits Enable MSI with 1 Mod 11 and 1 Mod 10 check digit Transmit no check digits Transmit 1 Check digit Transmit 2 Check digits Enable Plessey Code Enable LabelCode5 Enable LabelCode4

0 1 2 3 4 5 6 7 8 9

Plessey has two check digits which are not transmitted. MSI, Plessey, LabelCode4, and LabelCode5 are mutually exclusive. For information about MSI codes, see Appendix F. If you've enabled the Mod 10 or Mod 11 check digit(s), enabling transmission of one or two check digits causes the WDP Reader to transmit it/them to your computer along with the bar code data. Enabling check digit transmission (if check digit(s) are enabled) causes the WDP to transmit it/them to your computer along with bar code data.

RSS-14 Disable RSS-14 Enable Standard 14 digits Enable 14 plus Identifiers Enable 14 plus UCC 128 Emulation

0 1 2 3

By default, standard RSS-14 is disabled, scan 1 to enable. Options 3 and 4 enable the alternate RSS-14 formats. For more information on RSS-14, see the AIM website at http://www.aimglobal.org/standards/symbinfo/rss_overview.asp

Computer Interface PC Keyboard PC "learned timing"

1 3

If you are connecting to a USB (PC or Mac) port with any WDP, the Reader will sense the USB interface. No Computer Interface setting is necessary. The WDP automatically senses if you have a Y cable plugged into a PC keyboard port. If you have trouble with the PC keyboard interface, try the “learned timing” setting described below. Always test your keyboard after changing interface settings. If you see “garbage” on your screen, you may need to re-boot before continuing. The PC "learned timing" can learn your keyboard timing and save it. Scan Start Setup, Computer Interface, 3 for PC and then press a key on the computer keyboard (the WDP beeps once). Now scan End Setup and the timing is captured by the WDP. Learned timing does not apply to a USB connection of any kind. 2-7

Page 16

Preamble A "Preamble" is a user-specified data string transmitted at the beginning of each bar code. For example, if you specify the preamble @@ and read data of 123456, "@@123456" would be transmitted to your computer. The default is no preamble. To select a preamble, scan up to 15 characters from the "FULL ASCII MENU" on the back of the Reader Setup Menu, and then scan SET when you're done. To return to the no preamble setting, scan CLEAR here instead of scanning SET or any characters from the FULL ASCII MENU. You can trim 1-15 leading characters from bar code codes by scanning a ~ (tilde -- ASCII 126) followed by a single digit, 1 through F (A through F are for 10 to 15), as part of the Preamble. (Bar codes which are shorter than the amount-totrim are transmitted with no trimming.) Consider the examples in the following table to understand how trimming works: Bar Code Data

Preamble

Data Transmitted

123 12345678 12345678 12345 123456

XYZ ~3XYZ ~9 ~A ~5

XYZ123 XYZ45678 12345678 ~A12345 6

You can also trim selectively by bar code type. For example, you can trim 2 characters from Code 39 and a different amount from other bar code outputs. This is done by using the bar code ID character in conjunction with the tilde (~). A preamble of ~b2~c1 says trim 2 characters from the front of Code 39 output and trim 1 character from the front of UPC-A. Refer to the Code 128 parameters previous discussion for a list of the ID character associated with each bar code type. For advanced PC users: Emulating special keys in the preamble: Programmers and other advanced PC users can also embed keyboard hex scan codes in the preamble, for emulation of key presses specific to their computers, such as the left shift key or F12 key. This is done by specifying the make and break hex scan codes for one or more keys enclosed in "left" and "right" apostrophes (` and '). Make and break codes are hardware-specific -- see the keyboard section of your computer's manual or tech references for descriptions of its make and break codes. Break codes follow one of two conventions depending on which "keycode set" a keyboard uses. Keycode set 1 (usually on XT-style systems) uses a two-digit break code formed by adding hex 80 to the make code. Keycode set 2 (usually on AT-style systems) uses two digit break codes: the first is F0 and the second is identical to the make code. For example, let's say you want to emulate the left shift key. First, using the FULL ASCII MENU, you'd scan a left apostrophe, to identify subsequent characters as keyboard scan codes. Next, the two-digit hex make code -- let's say it's 2-8

Page 17

12. First you'd scan a 1 and then a 2. Next, the break code. Let's say your computer uses keycode 2 break codes of F0 followed by the make code. Finally, a right apostrophe to mark the end of the scan codes. ` 1 2 F 0 1 2 ' (scanned from the Full ASCII Menu) The preamble is limited to 15 characters. As the single scan code example above uses eight characters, you can see that you can't put very many keyboard scan codes in the preamble. A final use of the Preamble/Postamble is to enter a minimum/maximum length check for bar code data read. Use the Preamble or Postamble by entering |nnmm where "|" is ASCII 124, "nn" is the two digit minimum to be read and "mm" is the two digit maximum to be read.

Postamble "Postamble" refers to a user-specified data string transmitted at the end of each bar code. For instance, if you specify the postamble @@ and read data of 123456, "123456@@" would be transmitted to your computer. To select a postamble, scan up to 15 characters from the "FULL ASCII MENU" on the back of the Reader Setup Menu, scanning SET when done. To return to no postamble (the default setting), scan CLEAR here instead of scanning SET or any characters from the FULL ASCII MENU. You can trim 1-15 trailing characters from bar code codes by scanning a ~ (tilde -- ASCII 126) followed by a single digit, 1 through F (A through F are for 10 to 15). (Bar codes which are shorter than the amount-to-trim are transmitted without trimming.) Consider the examples in the following table to understand the options of the Postamble: Bar Code Data

Postamble

Data Transmitted

123 12345678 12345678 12345 123456

XYZ ~3XYZ ~9 ~A ~5

123XYZ 12345XYZ 12345678 12345~A 1

Bar codes which are shorter than the sum of the Postamble trimming and Preamble trimming will be transmitted without trimming. You can also trim selectively by bar code type. For example, you can trim 2 characters from Code 39 and a different amount from other bar code outputs. This is done by using the bar code ID character in conjunction with the tilde (~). A postamble of ~b2~c1 says trim 2 rightmost characters from Code 39 output and trim 1 rightmost character from the UPC-A. (Use m for trimming Magstripe). Refer to the Code 128 parameters previous discussion for a list of the ID character associated with each bar code type.

2-9

Page 18

For advanced PC users: Emulating special keys in the postamble See the "emulating special keys in the preamble" section on page 2-8. A final use of the Preamble/Postamble is to enter a minimum/maximum length check for bar code data read. Use the Preamble or Postamble by entering |nnmm where "|" is ASCII 124, "nn" is the two digit minimum to be read and "mm" is the two digit maximum to be read.

Data Transmission Timing None Short Short Medium Medium Long

0 1 2 3 4

Timing does not apply to any USB attachment. Before trying this, try the "learned timing" discussed on page 2-7. For Computer Interface 1, the WDP Reader can transmit bar code data at five different rates. Most computers work at the fastest speed ("None"), but some systems require slower rates. Try the "None" setting, and (when you're done configuring it) try reading some codes. If you get partial or garbled reads, try other timing settings to solve the problem (the USB interface require any timing adjustments). Try each timing rate (fast to slow); don't assume that if the slowest and fastest don't work, the intermediate settings won't either. After each failing attempt at timing setting, type "12" in the upper keyboard row to be sure the keyboard has not been locked or confused; if the "12" doesn't type correctly, reboot before trying a new timing setting.

Reset Don't scan Reset unless you're sure you want to restore the WDP Reader to its default settings (as described on page 2-1), erasing all changes you've made, because that's exactly what Reset will do.

MagStripe (P22 reader only) Autosensing - None Track 1 (autosensing) Track 2 (autosensing) Track 3 (autosensing) Dual Track Scanner,Output both only (autosensing) Dual Track Scanner,Output both or 2 only Track 1 or 3 Only on Dual Track Scanner Track 2 only output on Dual Track Scanner Track 1&2&3 Scanner, all 3 or 1&2 only (autosensing) Track 1&2&3 Scanner, all 3 or 1 only Caps Lock Off (just for MagStripe) Caps Lock On (upper case alpha for magstripe)

2-10

0 1 2 3 4 5 6 7 8 9 E F

Page 19

The P22 reader is autosensing for Magstripe scanners. If you have a scanner attached, most will be auto-sensed (see the settings above). If you have no magstripe attached, it will sense that too. If you need to use one of the settings that are NOT autosensed, you will have to make the change yourself. For example, if you have a dual-track scanner and want to read both tracks 1 and 2, the P22 will autosense setting 4, but if you really want to read just track 2, you will need to manually change it to setting 5. (A scanner is required). For all Driver's licenses,(including California) setting 8 will be autosensed, but you will have to change it for setting 9. See page 3-9 for more information on the MagStripe scanner.

Characters This setup option allows you to output ASCII characters different from the ones scanned. (Don't use this option to configure the WDP Reader for your non-US keyboard -- instead, use the Keyboard Country option described below.) For example: Suppose you want the WDP Reader to output a hex 92 character every time you scan a 1 (hex 31); you want to remap hex 31 to hex 92, (If you're using 8 data bits, output of 80-F8 codes is possible.) Your Full ASCII Menu has ASCII and hex values for the 128 characters. 1) Scan the Start Setup Bar Code 2) Scan the Characters Bar Code on the Setup Sheet. 3) Scan 3 1 and 9 2 to output hex 92 when reading a "1". 4) Scan up to 7 other pairs of character reassignments. 5) Scan Set when complete. 6) Scan End Setup to exit setup mode. You can also eliminate characters by reassigning hex codes to FF. For example, to strip all $ (dollar sign) characters from transmission, you would follow the above instructions and scan 2 4 F F in step 3. Magstripe output is frequently required to be changed to conform to some specific software package's requirement. For example, you might want to change the = and ^ separator characters to spaces or CRs. Between trimming and replacement, you should be able to reformat the Magstripe output to conform to most requirements.

Keyboard Country This option configures the WDP Reader for your choice of 15 keyboard country settings, such as USA (the default), UK, French, German, etc. Scan the keyboard country bar code and then the two-digit code for your keyboard country (listed on the Reader Setup Menu), such as 14 for UK. USA 00 Fr. Canadian 04 Latin America 08 Swedish 12

French Danish Norwegian Swiss

02 German 05 Dutch 09 Portuguese 13 U.K.

2-11

02 06 10 14

Belgian Italian Spanish

03 07 11

Page 20

Terminator Characters Enter (carriage return) None Tab

0 1 2

Depending on your application, you may wish the WDP Reader to transmit bar code data to your computer with an Enter (carriage return), a Tab at the end, or with no extra terminating character at all. If you need a terminator character other than CR or HT (such as LF for UNIX), you can get it by specifying None here and then selecting your desired terminator character(s) through the Postamble specification.

Automotive Vin Character Replacement If you want to strip off the leading character "I" (which some imports have) from the VIN: Scan Start Setup, Characters, 49F1, Set, End Setup. The "49F1"means strip off the "I " (hex 49) if it is in the first position (F1) of the barcode only.

2-12