Page 37
Poor read rate •
Try reading the test label on page 3-2 (following the scanning instructions in Chapter 3) as an example of a known good bar code. Examine your bar codes to make sure they have dark bars, clearly defined bars and white spaces, and a "quiet zone" of at least 1/4 inch to the left and right. If the bars are grey, or so dark that they "bleed" into the white spaces, the person or organization printing them will need to adjust the printer or get a new ribbon or toner cartridge for it.
•
Carefully follow the scanning instructions in Chapter 3 when reading any and all bar codes. As straightforward as scanning may seem, many people who call Worth Data with a complaint about poor read rate are simply not doing it correctly.
•
If you're using an infrared bar code wand, be sure the bar codes you're trying to read were printed with infrared-quality ink. Make sure you're using the right type of wand for the type of bar codes you're trying to read.
•
Pry the wand tip off; clean the inside with a soft, lint-free cloth. Carefully blow off any debris from the red plastic lens.
•
Erratic or low read rates can also result with systems that supply unusually low current or voltage to the keyboard. To test for this, turn your system off, disconnect the keyboard from the "Y" cable, and turn it back on. Then try reading the same bar codes. The system will probably be in a keyboard error state and not display the bar code data on the screen, but all you're interested in is listening for the beeps that signify good reads. If the WDP Reader has a much higher read rate without the keyboard attached, you can probably solve the problem by using a Worth Data regulated 5-volt external power supply (F10).
5-volt power adapters for keyboard wedge installation: The 5-volt adapter (F10 for 110V, F11 for 220V, F14 for UK 220V, and F13 for Australia 240V) is used to power the WDPs with separate decoder box configurations (P22) where the computer supplies unusually-low voltage or current to the keyboard. Don't use anything but a Worth Data power supply or you will probably damage the reader. The Worth Data power supply is regulated and has a specific polarity. Almost all other power supplies are unregulated and will damage the WDP is used. Just because the connector fits, don't use it. If your power supply does not display this label, it does not belong to your WDP reader. Only plug in a power supply that comes from Worth Data and displays this label. 5-3
Page 38
Appendix A
Specifications for Code 39 Code 39 (or Code 3 of 9) is the de facto standard of non-retail American industry. It is widely used in the automotive industry (AIAG specifications) as well as in government and military applications (LOGMARS 123ABC specifications). Code 39 is flexible, features a large character set, variable data length and density, and bi-directional readability. Code 39 is extremely accurate; substitution errors are almost nonexistent. Its character set consists of numbers 0 through 9, upper case A-Z, and characters Space, $, %. / + and -. The name "Code 39" comes from both the fact that its character set originally contained 39 characters (it now has 43) and from its structure. Each character is formed of three wide and six narrow elements, made up of five bars and four spaces. Code 39's density can vary from a low of .75 characters per inch (cpi) to a high of 9.4 cpi. There should be a ¼" "quiet zone" (white space) to the left and right of the bar code. Code 39 uses an asterisk (*) as a start and stop character. This character must precede and follow the data in the bar code. The WDP gives you the option of transmitting or not transmitting these characters when the bar code is read. Exact specifications for Code 39 and other bar code symbologies can be obtained from ANSI at the address below: American National Standards Institute Customer Service 11 West 42nd St. New York, NY 10036 http://web.ansi.org document ANSI/AIM BC1-1995
A-1
Page 39
Mod 43 Check Character Standard Code 39 can be printed with a "Mod 43 Check Character". This Mod 43 check character cannot be used with Full Ascii Code 39. The check character is derived by assigning a value to each character in the data to be bar coded from the table as follows: Char 0 1 2 3 4 5 6 7 8 9
Value
Char
Value
Char
Value
Char
Value
0 1 2 3 4 5 6 7 8 9 A
B C D E F G H I J K 10
11 12 13 14 15 16 17 18 19 20 L
M N O P Q R S T U V 21
22 23 24 25 26 27 28 29 30 31 W
X Y Z . Space $ / + % 32
33 34 35 36 37 38 39 40 41 42
Here is an example to illustrate how the check character is calculated for bar code data of 123XYZ: 1. Take the sum of the values assigned to each character: 1 + 2 + 3 + 33 + 34 + 35 = 108 1
2
3
X
Y
Z
2 Divide the sum by 43: (thus the name modulus 43) 108/43 = 2 with a Remainder of 22 3. Find the character corresponding with the remainder. M (value 22) is the CHECK CHARACTER
The data becomes 123XYZM, with M added as the Mod-43 check character.
A-2
Page 40
Full ASCII Extension to Code 39 "Full-ASCII Code 39" expands the Code 39 character set to include all 128 ASCII characters. Symbols 0-9, A-Z and punctuation characters . and - are identical to their Code 39 representations. Lower-case letters, additional punctuation characters and control characters are represented by sequences of two Code 39 characters. This table depicts the Full ASCII character set as a function of Code 39 characters: ASCII
C39
ASCII
C39
ASCII
C39
ASCII
C39
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
%U $A $B $C $D $E $F $G $H $I $J $K $L $M $N $O $P $Q $R $S $T $U $V $W $X $Y $Z %A %B %C %D %E
SP ! “ # $ % & ‘ ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
Space /A /B /C /D /E /F /G /H /I /J /K /L - or /M . or /N /O 0 or /P 1 or /Q 2 or /R 3 or /S 4 or /T 5 or /U 6 or /V 7 or /W 8 or /X 9 or /Y /Z %F %G %H %I %J
@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _
%V A B C D E F G H I J K L M N O P Q R S T U V W X Y Z %K %L %M %N %O
‘ a b c d e f g h i j k l m n o p q r s t u v w x y z } | { ~ DEL
%W +A +B +C +D +E +F +G +H +I +J +K +L +M +N +O +P +Q +R +S +T +U +V +W +X +Y +Z %P %Q %R %S %T,%X
See page 4-1 for instructions on encoding Function, Control, Alt and Shift keys with Full-ASCII Code 39 bar code characters.
A-3
Page 41
Appendix B
Codabar a29934567a
Codabar is widely used in libraries, blood banks, the cotton industry and transportation industries. Its' character set consists of numbers 0 through 9, and punctuation characters + . - / : and $. Symbols a, b, c, d, t, n, * and e are used as start and stop characters. Characters are constructed of four bars and three spaces.
Codabar is a numeric-only code, but different combinations of start and stop characters can be used to identify different types of labels. Codabar's variable data length and extremely low error rate make for a versatile bar code. Codabar start/stop transmission The Codabar section on the WDP Setup Menu lets you determine whether Codabar start/stop characters are transmitted or not. If you are varying start/ stop characters with different types of labels, you'll want to "Enable Stop/Start character Transmission". Start/stop character transmission can also be helpful if you want your program to differentiate between data coming from the WDP reader and data coming from the keyboard. If neither of these situations apply, you'll probably want to disable it.
B-1
Page 42
Appendix C
Code 128 Specifications Code 128 is a very powerful bar code, combining an extensive character set and variable length with compactness and error checking. The character set contains all 128 ASCII characters with each character made up of three bars and three spaces. Each element (bar or space) varies AB123456 from one to four units in width, totaling 11 units of width per character. Code 128 contains two levels of error checking: • Each character is checked for internal parity, and • The last character is a checksum.
Code 128 has three subsets, A, B and C. Subset A contains alphanumeric characters and unprintable control characters, subset B contains alphanumeric characters plus printable control characters and subset C contains only numeric characters and uses a 2-character encoding scheme to create a more compact bar code. Code 128 uses an internal Mod 103 check character that is not displayed by the bar code reader. Code 128 bar codes can be made up of only one subset or may be a combination of several. The Code 39 features of Accumulate Mode, Caps Lock ON and Caps lock OFF also apply to Code 128.
UCC-128/ EAN-128 UCC-128/EAN-128 Code is a subset of Code 128 adopted by the UCC and EAN council's for use as a shipping label symbology. UCC/EAN-128 bar codes always start with a Function Code 1 character. In addition, all variable length fields are terminated by a Function Code 1 character unless they are the last field in the bar code. The WDP outputs the following for the special function codes and start sequences: ]C1 Start C/Function Code 1 ^]
(GS) Function Code 1 as a variable string terminator
If UCC/EAN 128 is enabled, the WDP reader looks for the Start C/Function Code 1 characters to indicate a UCC/EAN 128 bar code. The UCC Serial Shipping Container Code specification calls for a 19 digit UCC/EAN 128 code with an additional Mod 10 Check Digit (20 digits in all for the code). The Mod 10 Check digit is calculated the same as the Interleaved 2 of 5 example in Appendix D. It is the data length as well as the MOD 10 check digit that distinguishes the Serial Shipping Container Code from other UCC /EAN 128 bar codes. C-1
Page 43
GS1-128 UCC/EAN 128 is enabled by scanning the appropriate bar codes on the WDP Reader Setup Menu. If UCC/EAN 128 is enabled, you will be able to read both standard Code 128 as well as the UCC/EAN 128 bar codes with the Function 1 character and the Mod 10 check digit. The GS1-128 UCC 128 specification is used extensively by the retail industry. If you have a requirement for a UCC 128 Serial Shipping Container bar code, be
GS1-128 UCC/EAN Code 128 Serial Shipping Container Code sure to follow the specification as closely as possible as many vendors will impose fines for non-conformance. For more information on GS1-128 UCC 128, contact the GS1 (formerly the Uniform Code Council) at:
GS1 US 7887 Washington Village Drive, Suite 300 Dayton, OH 45459 ph 937-435-3870 fax 937-435-7317 email: info@gs1us.org 8:00 am to 6:00pm EST Mon-Fri Many of the specifications are available online at: http://www.gs1us.org
C-2