Page 33

For example, if the WDP reads the bar code SOH (ASCII 001 -- a control-A) from the FULL ASCII MENU, it will transmit an F1 key sequence to your computer. Function keys F11 and F12 Function keys F11 and F12 require two bar codes to be scanned to make these functions keys. The F11 key is created by combining the Null and SOH. The F12 key is created by combining the Null and the STX . Shift, Ctrl and Alt keys Shift, Ctrl and Alt keys require three sequences 1) The ON code generated when the Shift, Ctrl or Alt key is pressed. 2) The other key to be used in conjunction with the Shift, Ctrl or Alt key. 3) The OFF code generated when the Shift, Ctrl or Alt key is released. For example, to properly emulate the keystrokes for Ctrl-C, you would scan the bar code for Control ON (FS), C, and Control OFF (GS). Windows Key The Windows key on a Windows keyboard is transmitted by scanning 4 bar codes - NULL and C for Windows On (pressing down) and NULL and D for Windows Off (releasing the key). Macintosh Command and Option Keys on USB When you have a WDP Reader attached to a Macintosh Computer's USB port, to emulate the Command key, use the Windows key ON/OFF bar codes NULL, C (Command ON) and NULL, D (Command OFF) For the Option Key ON/OFF use RS (Option On) and US (Option Off ). If you have an older Worth Data Reader (before 6/99), you can also imitate the Command Key by keycodes in the Preamble/Postamble. To transmit Command N would be:`E01F'N`E0F01F' Transmitting any ASCII character using its 3-digit ASCII code You can also transmit any ASCII character from 000 to 255 by emulating the PC technique of typing a character's ASCII number on the numeric pad while holding down the Alt key. For example, to transmit ASCII 250, you would scan the bar codes for: Keystroke

Full ASCII Menu Bar Code

Alt ON RS Ins (0 on the numeric pad) DC2 Down Arrow (2 on the numeric pad) NAK Numpad 5 LF Ins (0 on the numeric pad) DC2 Alt OFF US

4-2

Page 34

Accumulate Mode Accumulate Mode is an option (which can be enabled or disabled using the Reader Setup Menu's Code 39 section) allowing the reader to accumulate multiple bar codes in its buffer, then transmit them to the computer as if they had been a single bar code. This is useful for entering quantities and other variable data. It works with Code 39 only, and can't be used with a check digit. When the reader reads a bar code with a leading space, it beeps and buffers the data without transmission. It continues to read and buffer bar codes (up to 40 characters) until it reads a bar code without a leading space. Then the entire buffer (including that last code) is transmitted as one long bar code. A bar code of a double minus (--) sign clears the buffer. Scanning a backspace code ($H) backspaces in Full ASCII mode. A handy code for Enter (as seen on the "Barpad" below) is a Start/Stop only. (No data.) If you don’t have a Terminator Character programmed, you will have to scan a CR (see the Full ASCII menu) instead of the Enter bar code shown below. This numeric "Barpad" illustrates Accumulate Mode. Scan 5, 3, 8, and Enter. The reader transmits a single message of 538.

0

1

2

3

4

5

6

7

8

9

Clear

Backspace

Enter 4-3

Page 35

Chapter 5

Troubleshooting A reader P22 installed in Wedge mode using a Y-Cable doesn't beep three times when you power up your system, or the keyboard locks up, or you get a "keyboard error" or "301" message. •

Check the cable connections to make sure everything is plugged in securely. With a PC, make sure the keyboard cable is plugged into the keyboard port (Purple on modern PC’s) rather than the mouse port (Green).

•

If, after checking the connections, you still have a problem, your computer and keyboard combination probably doesn't have enough left-over power to drive the bar code reader also. Disconnect the scanner from the WDP P22 Reader and reboot your system. If the system boots correctly when the scanner is not attached, you solve the problem by ordering a Worth Data 5volt external power supply (part number F10) for your P22 WDP.

•

If the system still doesn't boot correctly with the scanner disconnected, a Worth Data regulated power supply (don't use someone else's power supply or you will damage the reader) - will probably still correct the problem. If you are using a USB reader and there many devices, you may need either a power supply on the WDP (P22 only), or you may need a powered USB hub device.

Using USB, the reader initializes and then turns off. • There is not enough power available on the USB port. If you are connected to a USB port on the keyboard, try connecting to a USB port on the CPU itself. You may need to buy a powered USB Hub with its own power supply - you can pick them up inexpensively at your nearest computer store. Using USB, the reader powers up and beeps when a bar code is scanned but no data is transmitted. • Go to the Control Panel, then to System, then Device Manager. Check your HID devices. Right click on the HID device to see if the device is working properly. If it is not, click on Driver and proceed to reinstall the driver. See Appendix I for details for your operating system. The reader won't beep when reading bar codes •

Recheck all the connections using the installation section as a guide. Try reading a known good bar code - the test label on page 3-2, following the steps for scanning in Chapter 3; Scanners and Scanning Technique. If you're trying to read Code 39 bar codes with leading spaces (such as the Barpad on page 4-3) and have enabled Accumulate Mode, those bar codes will not be transmitted to your computer until you read a bar code without a leading space. Try reading the Test Label on page 3-2 as an example of a known good label.

•

If the read failure is on Interleaved 2 of 5 codes, make sure the data length is the same that you selected on the Reader Setup Menu. Be sure you don't 5-1

Page 36

have the check digit enabled for Code 39 or Interleaved 2 of 5 if you're trying to read data without check digits. • If you are using a laser scanner (especially a long-range laser), you may need to increase the length of time the scanner attempts to read. The default is a 2-second beam. To change to a 4-second beam, scan Start Setup, 2 of 5 Code, F, then End Setup. Scanning E instead of F sets the beam back to 2 seconds. • If you are using a P22 decoder connected the a USB port with an older wand scanner, you need to open the P22 decoder and change the S1 switch to “wand” instead of “laser”. Typical symptoms are a dim wand light and no reading. See Appendix J for a diagram. Extra characters at the beginning or end of your bar code data • Clear the Preamble and Postamble. • Make sure you haven't enabled transmission of any start/stop characters, checksums, leading digits or terminator characters that you don't want transmitted. For UPC-E, select Compressed transmission if you don't want it padded with extra zeros. The reader transmits incorrect data to the screen Reread page 2-7 and make sure you chose the proper Computer Interface. • If part of the data is correct and part missing, you need to tell the WDP

Reader to transmit data at a different rate. First try Learned Timing on page 2-7, and if that doesn't work, resort to changing Data Transmission Timing on page 2-10 (Keyboard Interface ONLY). • If the reader is transmitting punctuation characters (!@#$%^&*) when reading numeric bar codes, or transmitting letters in the wrong (upper/ lower) case, you may have a Num Lock, Caps Lock, shift or timing problem. Check your keyboard to see if the Num Lock or Caps Lock keys have been activated. Finally, try "learned timing" (See Page 2-7) or changing your Data Transmission Timing (See page 2-10). • If you're using Code 39, read page 2-4 to see if you've set Caps Lock properly for your application. If your Code 39 bar codes include punctuation characters %, $, / or +, the reader is seeing them as part of Full-ASCII Code 39 sequences. Using the Reader Setup Menu, disable Full ASCII Code 39. • If you are using a laser scanner and are reading poorly printed codes or scanning through a windshield, make sure “double-scan checking” is enabled (It is the default setting). “Double-scan checking” does take longer (it forces the reader to keep scanning until it gets two identical reads) but will eliminate mis-reads. “Double-scan checking” is set under the Code 39 setup parameter by scanning Start Setup, Code 39, E, then End Setup. Scanning F instead of E will disable this option.

5-2