Page 31

2-Way Laser Operating Instructions Operational Details The two-way LZ202-RF Laser Scanner and LI102-RF Linear Imager CCD: 1.

chirps on a "good read" or successful scan while turning off the scanner beam, and

2.

beeps loudly when it gets the acknowledgement back from the Base Station that it has received the data.

The yellow light on the back of the scanner indicates that it is transmitting. You will see up to four transmission attempts before the unit goes to sleep and waits for you to pull the trigger again. The green light indicates that it has received the acknowledgement from the Base Station. After four unsuccessful tries of transmitting to the base without an acknowledgement, the scanner chirps 8 times and goes to sleep waiting on the operator to move closer to the base station and pull the trigger again for a transmission retry. After going to sleep on an unsuccessful read, when the trigger is pulled again, the scanner beam doesn't turn on for reading; instead, the unit beeps three times to indicate is re-transmitting and just transmits again. This sleep and retransmission cycle is repeated until the acknowledgement is received or the buffer is deliberately cleared. In this way, no scanned data is lost, even though you have wandered out of range of the Base Station. Until the pending data acknowledgment has been received, pulling the trigger will only retransmit and not activate the scanning laser beam for additional reading. If you are out of range and want to clear data in the scanner's buffer waiting to be transmitted again, by pulling the trigger and holding it down for 15 seconds, the buffer will be cleared and the scanner will emit 3 low pitched beeps.

Multiple Scanners on one 2- Way Base Station Multiple 2-way scanners can talk to one base station on the same frequency by scanning a unique ID Character in each scanner. Just scan Start Setup, Set ID Character, and the 1-8 followed by End Setup for each scanner, (using a different value 1-8 for each scanner). Remember though, the scanning throughput is dependent on the total volume of scanning from all scanners assigned to the same frequency sharing a base station. If two scanners transmit at the same time, the base station will receive neither of the messages and both scanners will wait for a random time and retransmit. The random wait before retransmission assures maximum probability of both getting through. If there are too many collisions in radio transmission, the scanning rate will be slow. The fix is to buy more base stations of a different frequency and get a portion of the scanners changed to the frequency of the additional base station.

27

Page 32

Multiple 2-Way Base Stations on the Same Frequency. Although not recommended, you can have more than one two-way base station on the same frequency operating in a common area, but you must set each grouping of assigned scanner(s) with the ID of the Base Station. All other Base Stations with a common frequency must be turned off during the setup of another base and/or associated laser scanners. Otherwise, all base stations that can hear will be set to the same ID Character and its purpose will be defeated. Base Station IDs are a-z and Scanner IDs are 1-8. This is not recommended because of interference. However, occasionally, there will be need for more base stations than the number of available frequencies. Providing that you keep the overlap to the fringes of coverage, this feature makes it impossible for two base stations on the same frequency to receive the same data.

28

Page 33

Accumulate Mode Accumulate Mode is an option (which can be enabled or disabled using the Reader Setup Menu's Code 39 section) allowing the reader to accumulate multiple bar codes in its buffer, then transmit them to the computer as if they had been a single bar code. This is useful for entering quantities and other variable data. A small laminated barpad card is provided with each reader ordered to aid in entering variable quantities. It works with Code 39 only, and can't be used with a check digit. When the reader reads a bar code with a leading space, it beeps and buffers the data without transmission. It continues to read and buffer bar codes (up to 40 characters) until it reads a bar code without a leading space. Then the entire buffer (including that last code) is transmitted as one long bar code. A bar code of a double minus (--) sign clears the buffer. Scanning a backspace code ($H) backspaces in Full ASCII mode. A handy code for Enter (as seen on the "Barpad" below) is a Start/Stop only. (No data.) The code to use for testing the transmission link between the R/F Scanner and the R/F Base Station is the CLEAR BUFFER code (the same bar code as titled Link Test on the Setup Menu. It will cause beeps to be heard, but no data will be transmitted to the computer -- testing blind with no computer consequence. This numeric "Barpad" illustrates Accumulate Mode. Scan 5, 3, 8, and Enter. The reader transmits a single message of 538.

7

8

9

4

5

6

1

2

3

0

Clear Buffer

29

Enter

Page 34

Function/Control Key Support The RF Scanner can also transmit key sequences for function, control, alt (command and option keys on Macs), cursor and shift keys, for ease of use with the many software packages using these keys for menus or commands. You can include these codes in other bar codes, or you can scan these “keystrokes” into your Preamble or Postamble in order to add them to every scan from your reader. You must have Full ASCII Code 39 enabled on your reader (this is the default setting). Scan the corresponding bar code from the Full ASCII menu to emulate the chosen key. PC Key

Mac ADB Keyboard

Full ASCII Menu Bar Code F1 F1 SOH (f1) F2 F2 STX (f2) F3 F3 ETX (f3) F4 F4 EOT (f4) F5 F5 ENQ (f5) F6 F6 ACK (f6) F7 F7 BEL (f7) F8 F8 SO (f8) Numpad 5* Enter LF Enter Return CR F9 F9 SI (f9) F10 Cmnd On DLE (f10) Del Del DC1 (Del) Insert Cmnd Off DC2 (Ins) Left Arrow* Left Arrow DC3 ) Rt Arrow* Rt Arrow DC4 Dn Arrow* Dn Arrow NAK Up Arrow* Up Arrow SYN ( ) Pg Up* Pg Up VT (Pg Up) Pg Dn* Pg Down FF (Pg Dn) Home* Home ETB (Home) End* End CAN (End) Shift ON Shift ON EM (Shift ON) Shift OFF Shift OFF SUB (Shift OFF) Control On Control On FS (Ctrl ON) Control Off Control Off GS (Ctrl OFF) Alt On Option On RS (Alt ON) Alt Off Option Off US (Alt OFF) * refers to the keys on the Number pad on the far right side of a PC keyboard. To emulate any of the keys above, scan the appropriate bar code from the FULL ASCII MENU. For example, to emulate the f5 key, scan the ENQ bar code. 30

Page 35

Function keys F1 through F10, and numeric-pad keys (such as Left Arrow and Del), are encoded by a single control character as shown in the table above. Simply scan the correct bar code from the FULL ASCII MENU. For example, if the WDP reads the bar code SOH (ASCII 001 -- a control-A) from the FULL ASCII MENU, it will transmit an F1 key. Shift, Ctrl and Alt keys require three sequences: 1) The ON code generated when the Shift, Ctrl or Alt key is pressed. 2) The other key to be used in conjunction with the Shift, Ctrl or Alt key. 3) OFF code generated when the Shift, Ctrl or Alt key is released. (For example, to create a Control C bar code: use Control ON, C, and Control OFF. To put Control C in a Preamble or Postamble, scan from the Full ASCII Menu: Control ON, C, and Control OFF). Center Control Keys The Center Control Keys in the keyboard have to be used for a Mac with USB for control keys. If you scan bar codes mapped to the control keys on the far right of the keyboard, you will get numbers because the Mac USB keyboard is always in Num Lock. On other keyboards, if you want your application to be immune to the setting of the Num Lock key, use the bar codes mapped to the Center Control Keys instead of the keys on the Full ASCII menu. The below chart corresponds to the small center section of keys between the main letter keys and the Numeric keypad on the far right of the keyboard and requires you to scan two bar codes from the FULL ASCII MENU - the NULL bar code and then the appropriate character. For example, to emulate the END key, scan the NULL bar code, then the 1 bar code. PC Key

Mac USB Key

Insert Delete End Down Arrow Page Down Left Arrow Line Feed Right Arrow Home Up Arrow Page Up Windows ON Windows OFF ENTER (num)

Ins del end down arrow page down left arrow Line Feed right arrow home up arrow page up Command ON Command OFF ENTER (num) 31

Full ASCII Menu Bar Codes NUL 0 NUL . (period) NUL 1 NUL 2 NUL 3 NUL 4 NUL 5 NUL 6 NUL 7 NUL 8 NUL 9 NUL C NUL D NUL E

Page 36

Function keys F11 and F12 Function keys F11 and F12 require two bar codes to be scanned to make these functions keys. The F11 key is created by combining the Null and SOH. The F12 key is created by combining the Null and the STX. Windows Key The Windows key on a Windows keyboard is transmitted by scanning 4 bar codes - NULL and C for Windows On (pressing down) and NULL and D for Windows Off (releasing the key). Command and Option Keys on Mac USB Keyboards When you have a WDP Reader attached to a Macintosh Computer's USB port, to emulate the Command key, use the Windows key ON/OFF bar codes NULL, C (Command ON) and NULL, D (Command OFF) For the Option Key ON/OFF use RS (Option On) and US (Option Off). If you have an older Worth Data Reader (before 6/99), you can also imitate the Command Key by key codes in the Preamble/Postamble. To transmit Command N would be:`E01F'N`E0F01F' Transmitting any ASCII character using its 3-digit ASCII code You can also transmit any ASCII character from 000 to 255 by emulating the PC technique of typing a character's ASCII number on the numeric pad while holding down the Alt key. For example, to transmit ASCII 250, you would scan the bar codes for:

Keystroke Alt ON Ins (0 on the numeric pad) Down Arrow (2 on the numeric pad) Numpad 5 Ins (0 on the numeric pad Alt OFF

32

Full ASCII Menu Bar Code RS DC2 NAK LF DC2 US

Page 37

Troubleshooting All Models Troubleshooting The beam won’t stay on, or I just get a narrow beam when I pull the trigger, or The scanner won’t turn on when I pull the trigger and I get 3 beeps • All of the above problems are an indication that your BATTERIES ARE TOO LOW. With any of the above symptoms, change to known good batteries before assuming you have some other kind of problem. Also, make sure the batteries are inserted CORRECTLY – batteries won’t work if they are not inserted in the right direction. See page 51 concerning changing batteries and the correct battery orientation. The reader won't beep when reading bar codes • Recheck all the connections. Get close to the Base Station. Try reading the Link Test bar code, following the steps for scanning on pages 10-11.

•

If you hear two beeps, but see nothing on the screen, and you are reading the pocket card, you must read the ENTER bar code to have anything transmitted. Any Code 39 or 128 bar code with leading spaces (such as the Barpad on page 28) will not be transmitted to your computer until you read a bar code without a leading space. Try reading the Test Label on page 25 as an example of a known good label without a leading space. If you have bar codes with leading spaces in them, and you want them transmitted, you must disable Accumulate Mode using the Setup Menu.

•

Reread the configuration section and make sure you properly enabled the bar code types you're trying to read.

Extra characters at the beginning or end of your bar code data • Clear the Preamble and Postamble. Poor read rate • Get close to the Base Station and try reading the test label on page 25 (following the scanning instructions on pages 10-11) as an example of a known good bar code. Examine your bar codes to make sure they have dark bars, clearly defined bars and white spaces, and a "quiet zone" of at least 1/4 inch to the left and right. If the bars are gray, or so dark that they "bleed" into the white spaces, the person or organization printing them will need to adjust the printer or get a new ribbon or toner cartridge for it. I get six beeps when the One-Way Base Station powers up or six flashes on the 2-way Base Station. • The unit needs repair. Call for an RMA. 33

Page 38

The Decode Green Light on LZ200-RF One-Way Laser or LI101-RF Linear Imager CCD stays lit. • On One-Way units, the batteries will run down real fast too. This means that you are still in Setup Mode. Scan End Setup to turn the light out. The Orange light stays on the LZ202-RF 2-way RF Laser Scanner and LI102-RF Linear Imager Scanner. • You are in Setup Mode. Scan End Setup on the Wireless Setup Menu.

Wedge Troubleshooting A one-way base station installed in Wedge mode doesn't beep three times when you power up your system; or a 2-way base doesn't go from red to green on the front LED; or the keyboard locks up; or you get a "keyboard error" or "301" message. • Check the cable connections to make sure everything is plugged in securely. 6 pin mini-din keyboard connectors can sometimes be tricky - make sure they're plugged in as far as they can go. Make sure you plug the Y-cable into the keyboard port rather than the mouse port.

•

If, after checking the connections, you still have a problem, your PC and keyboard combination probably doesn't have enough leftover power to drive the bar code reader also. Don't use any old 5V power supply; it must be regulated and must be the right polarity, otherwise you will damage the Base Station. Order a 5-volt external power supply (feature code F10 or 110V, F11 for Euro 220, and F14 for the UK).

The reader transmits incorrect data to the screen • Reread page 17 and make sure you chose the proper Computer Interface.

•

If part of the data is correct and part missing, first try the PC Keyboard “Learned Timing”. If that doesn't work, you will have to tell the R/F Reader to transmit data at a slower rate, by changing Data Transmission Timing. Read page 16 on Data Transmission Timing.

•

If the reader is transmitting punctuation characters (!@#$%^&*) when reading numeric bar codes, or transmitting letters in the wrong (upper/lower) case, you may have a Num Lock, Caps Lock, shift or timing problem. Check your keyboard to see if the Num Lock or Caps Lock keys have been activated. If you have a PC, try the Learned Timing setting. Finally, try Data Transmission Timing (See page 16). Timings are fixed for Mac; no need to try to change.

•

If you're using Code 39, read page 13 to see if you've set Caps Lock properly for your application. If your Code 39 bar codes include punctuation characters %, $, / or + which don't up in the output, the reader is seeing them as part of Full-ASCII Code 39 sequences. Using the Reader Setup Menu, disable Full ASCII Code 39. 34

Page 39

Serial Troubleshooting The reader beeps on reads, but nothing appears on your screen using PortKey OR nothing appears to your own software. • Recheck the installation instructions beginning on page 2 to make sure all cables are properly connected.

•

If you're trying to read Code 39 bar codes with leading spaces (such as the Barpad on page 28) and have enabled Accumulate Mode, those bar codes will not be transmitted to your computer until you read a bar code without a leading space. Try reading the Test Label on page 25 as an example of a known good label.

•

If you're using PortKey on an IBM-compatible, verify (1) that you set the reader to the same settings as the DOS MODE command (baud rate, data bits, stop bits, and parity); and (2) that you ran PortKey with the correct serial port as a parameter (i.e.: Portkey Com1).

•

If you're using your own software to read the serial port, verify that the problem is not in your software. Run the WDR Serial Test Program that shipped with your reader and see if it gets any data on the screen when you read a bar code.

•

Use a "null modem" connector to test switching pins 2 and 3 on one or more serial cables, or use a breakout box to modify your cable(s).

The reader doesn't beep when you try to read your bar codes. • Make sure the power adapter is plugged in.

•

Try reading a known good bar code -- the test label on page 25, following the steps for proper scanning technique on page 11.

•

Read the instructions beginning on page 9 on configuring the Reader for different bar code types and formats, and make sure you properly enabled the bar code types you're trying to read.

Data characters are garbled or missing. • Make sure you've set the reader to the same baud rate, parity, data bits and stop bits as your serial port.

•

If Code 39 bar codes are transmitting in the wrong case (upper and lower transposed), set Caps Lock Off on the Setup Menu.

•

If you're getting occasional extraneous characters, try cutting the jumper between pins 8/20 in the serial Y-Cable's DB25 connectors. See page 8.

35

Page 40

My system locks up or I get Windows General Protection Faults when using my serial RF Reader on a PC running Windows. • This is an interference problem and occurs if you are using a serial extension cable over 80 feet long in combination with our F36 9-pin serial cable or F34 25-pin serial cable shipped before 9/15/01, or you have built your own cable (over 80 ft) and are not using our F36 or F34 cable. All F36 9 pin serial cables shipped after 9/15/01 have pins 4,6,7, and 8 cut at the DB 9 end of the cable. If you have one of the older cables or have built your own, you need to cut pins 4,6,7, and 8 at the 9-pin end of the cable; see page 8 for details on which pins should remain connected. All F34 25 pin serial cables shipped after 9/15/01 have pins 4,5,6,8,and 20 cut at the DB25 end of the cable. If you have one of the older cables or have built your own, you need to cut pins 4,5,6,8, and 20 at the 25pin end of the cable; see page 8 for details on which pins should remain connected.

36