Page 49

QuickLink-Pen® Elite Operation Manual 6. This setting affects future scanning into the current file only. Any new file created will be set to the scanning language that is set in the Set Scanning Language option in the Settings menu of the Pen Main Menu.

Scanning Options

Select the Scanning Options to temporarily change the scanning option for the next time you enter text into the current field. The following scanning options are available. You can select any or all of these settings. • Numeric: For a string of numbers. • Inverse: For light text on a dark background. • Multiple Lines: To store more than one line of text. When this option is selected, a new line is opened in the same field after each line is scanned. To continue to the next field you will need to press . , , or to toggle an option on or off. A checkmark ( ) is displayed when the option is on. Press Press to close the Scanning Options, save your settings and return to the table you were editing.

Insert Row

Select this option to add a row to the open table file. The row is inserted above the current row.

Insert Column

Select this option to add a column to the open table file. The column is inserted before the current column.

Remove Row

Select this option to remove the current row from the open table file.

Remove Column

Select this option to remove the current column from the open table file.

Insert Line

Select this option to insert an additional line in the current cell, after the current line. Note: If the Multiple Lines scanning option is activated for this cell, you just need to scroll to the last line in the cell and press in order to add a line.

Delete Line

Select this option to delete the current line from the cell.

Creating and Opening Tables

From the Tables main menu, select any of the following options: • Select Edit Current File to open the current file. The ‘current’ file is the one whose name appears in the caption of this menu. If no file is currently open, the message No Open File appears in the caption. In this case, selecting Edit Current File will first show the message No Open File and then show the Enter file name dialog box, suggesting a new file name. • Select New File to create a new file and then open it. The Enter file name screen will first appear suggesting a default file name. • Select Open File to select an existing file and open it. A list will first appear suggesting all available files. The file opens and the blinking cursor indicates the point at which text will be inserted.

Editing Tables Easy Steps

1. Create or open a file (see above). The tables cells appear in Scan mode (see How to know which mode the Pen is in on page 50) – meaning you can simply start scanning and the cell will accept the scanned text. Each table cell has a caption with a letter (starting with A and continuing with B, C, D, etc.), indicating the column in which the current cell is positioned and a number (starting with 1 and continuing with 2, 3, 4, etc.) indicating its row. 2. Make sure the Pen screen displays the required cell; if not, scroll until it does. Then scan in the parallel cell from an English printout of a table, for example, if you wish to scan in the first cell of a table (top left cell), the Pen should display the A1 cell on its screen. Note: if you want to scan text that is in a different language, see Select Language on page 48. If you want to scan numeric or inverse text, or if you want a cell to contain more than one line, see Scanning Options on page 49. 3. The new text appears in the cell and the new text is highlighted. 4. If the scanning results on the screen are not satisfactory, you can edit the cell in various ways - see Editing Existing Text on page 50. 5. Scroll to the next cell (scrolling to the right will proceed to the next cell in the same row, scrolling down will scroll to the next cell in the same column). 6. Continue scanning the table cells. 7. When done, press (once if in Scan mode, 3 times if in Edit mode) to close the file and save your changes. The Tables main menu is displayed.

49

Page 50

QuickLink-Pen® Elite Operation Manual

Editing Existing Text

There are 2 modes for editing existing text – Scan mode and Edit Mode. The mode affects the editing of the current field (cell) - meaning you must currently be in an open field.

Scan Mode

This is the default mode in the Tables application. When the current field is in Scan mode, scanning new text will delete any text from the whole field (if existing) and replace it with the new text you have scanned. This is useful for rescanning the whole field.

Edit Mode

When the current field is in Edit mode, you can do any following: • Insert Text: scan new text you want to insert into the current field. Please scan whole words and not single characters (for single character editing, use the Character Bar or the Opticard). The new text is inserted where the cursor was positioned and spaces are added to create correct word separation within . This will delete the new scan which the line of text. To quickly undo this new scan, simply press initially appeared highlighted (it appeared highlighted to allow this quick undoing). If you do not want to undo the new scan, press the arrow buttons to de-highlight the text, before entering more text. • Use the Edit Menu: press to access the Tables Edit Menu (see The Tables Edit Menu on page 48). • Use the Character Bar: press to display the Character Bar (see The Character Bar on page 67) and edit the point at which the cursor is inserted. • Use the Opticard: scan the Opticard key to activate the Opticard (see The Opticard on page 69) and edit the point at which the cursor is inserted.

How to know which mode the Pen is in •

•

In Scan mode the whole field appears with a black background and all the text is green. There is no blinking cursor. In Edit mode there is a blinking cursor in the current field.

Switching between Scan mode and Edit mode • •

If you are in Scan mode (no blinking cursor, field background is black), press to switch to Edit mode. If you are in Edit mode (blinking cursor), press twice to switch to Scan mode.

Navigation Shortcuts

Double-clicking the arrow buttons on the Pen quickly moves the cursor within the current cell (when the cursor is blinking - in Edit mode). Double-click To move the cursor to: this button The beginning of the cell The end of the cell

Scanning in different Languages

Please refer to Select Language on page 48.

Closing and Saving Table Files When done editing a file, press (once if in Scan mode, 3 times if in Edit mode) to close the table file and save your changes. The Tables main menu is displayed.

Exiting the Tables Application To return to the Pen Main Menu, press bottom of it.

from the Tables main menu or select the Exit option at the

Sending Stored Tables to the PC

Important: The transferal of stored file info between the Pen and PC requires Pen-PC Communications. Therefore, you must have already run the one time procedure Set Up Product on PC from the QuickLink-Pen® Elite CDROM. If you have not yet done this, please refer to Set Up Product on PC on page 8 and follow the instructions there. To send stored tables to the PC: 1. Turn your PC on. 2. Make sure that your Pen and PC are connected. Note: they should be connected in the same manner you had chosen during the Set Up Product on PC procedure of the QuickLink-Pen® Elite CD-ROM. For example, make sure that the USB plug side of the USB cable is connected to the USB outlet on your PC and that the other side of the cable is connected to the PC-Link Connector outlet of your Pen. 50

Page 51

QuickLink-Pen® Elite Operation Manual 3. Start the QuickLink-Pen Elite Desktop application and make sure that Pen communications are on (see How to know if Pen Communications are on, page 58). 4. Turn the Pen on. 5. Long press until you reach the Pen Main Menu. 6. Press until Send Stored Files to PC appears on the screen.

7. Press . The sending begins. Note: When performing Send Stored Files to PC, all stored files (from all storing applications) on your Pen are sent to the PC, according to the Pen-PC File Transfer Settings set in the Desktop application (see Setting the File Transfer Settings on page 52). 8. When the process is done, OK the pop up in the QuickLink-Pen Elite Desktop. 9. Click the Tables icon in the QuickLink-Pen Elite Desktop application. 10. The list of tables you had transferred from the Pen - appear on the screen. Note: By default, the stored files of the Tables application are copied from the Pen to the Desktop application and then deleted from the Pen. See File Transfer Settings for Tables on page 57 for information on changing these settings or having the files sent to additional PC applications such as MS Explorer.

51

Page 52

QuickLink-Pen® Elite Operation Manual

Sending Stored Files to the PC The transferal of stored data is possible between the Pen and the PC (Desktop and Host applications). The send function is performed for any storing applications you have installed. The available storing applications in this product are the default Scan and Store and Image Capture applications, plus the 3 add-on applications: Address Book, Internet Links and Tables. All these applications store text, except for the Image Capture application, which stores images. The sending is performed according to the settings set in the Pen-PC File Transfer Settings dialog in the Desktop application. The sending is initiated by the Pen, while the PC is prepared to receive this initiation. Following are instructions for setting and performing the Send Stored Files to PC operation.

Preparing the PC

Important: The transferal of stored file info between the Pen and PC requires Pen-PC Communications. Therefore, you must have already run the one time procedure Set Up Product on PC from the QuickLink-Pen® Elite CDROM. If you have not yet done this, please refer to Set Up Product on PC on page 8 and follow the instructions there.

Starting the Desktop Application

1. Turn your PC on. 2. Important: Close any applications that are running on your computer. The icons of the applications that are running on your PC appear in the System Tray. It is especially important to close applications that use the serial port of your computer, such as PDAs or digital camera applications. 3. Start the QuickLink-Pen Elite Desktop application: • If, during installation, you chose to add the Desktop to your computer’s startup, the Desktop will automatically start running when you start your computer, its window minimized. To reveal the Desktop window, click the Desktop icon ( ) in the system tray at the bottom of the screen. If the Desktop window does not appear, select the Show Window option from the pop-up menu. • If the Desktop application does not run when you start up your computer, or if you had closed the application, you can start it by opening the Windows Start menu and select Programs\QuickLinkPen Elite Desktop\QuickLink-Pen Elite Desktop. 4. For more information on the Desktop application, please refer to the QuickLink-Pen Elite Desktop Help file.

Setting the File Transfer Settings

When the option Send Stored Files to PC is selected on the Pen a transferal of files occurs between the Pen and PC. The settings for this transferal are set in the Pen-PC File Transfer Settings dialog in the Desktop. The dialog is preset to the default settings. If the following default settings suit your needs, you need not perform any of the procedures in this section you can continue to the next section - Confirming Pen-PC Communications on page 58.

The Default Settings

Following are the default settings for each of the storing applications, as set in the Pen-PC File Transfer Settings dialog in the Desktop: Note: The following list includes information for the add-on applications, which you may not have included in your product. If you wish to include any one of them, see Installing Add-On Applications on page 35.

52

Page 53

QuickLink-Pen® Elite Operation Manual Scan and Store: The stored text files of the Scan and Store application are copied from the Pen to the Desktop application and then deleted from the Pen (“flushed”). Image Capture The stored image files of the Image Capture application are copied from the Pen to the Desktop application and then deleted from the Pen (“flushed”). Address Book (add-on) All addresses from the main Address Book (mainadd) – both those stored in the Pen and those created or modified in the Desktop - are synchronized, resulting in one Address Book file (mainadd), identical on the Pen and on the Desktop. Internet Links (add-on) All links from the main Internet Links file (mainlnk) – both those stored in the Pen and those created or modified in the Desktop - are synchronized, resulting in one Internet Links file (mainlnk), identical on the Pen and on the Desktop. Tables (add-on) The stored table files of the Tables application are copied from the Pen to the Desktop application and then deleted from the Pen (“flushed”). If you wish to change any of these default settings – see the following instructions.

The Pen-PC File Transfer Settings Dialog Accessing the Dialog

In the Desktop application select Pen Communications from the menu bar and then select the Pen-PC File Transfer Settings … option. The Pen-PC File Transfer Settings dialog opens, displaying the current file transfer settings for each of the applications installed in the Desktop.

The Pen-PC File Transfer Settings dialog

The Application Settings

The Pen-PC File Transfer Settings dialog displays each storing application installed in your product and its current settings for the Send Stored Files to PC transfer. This information is displayed in the middle area of the dialog in a 4 column table. Following is a description of each column:

Application

Each row displays a different storing application which you have installed on your Pen and PC.

Mode

This is what will be done with the application files on the Pen and PC when performing the Send Stored Files to PC operation.

Flush

When on, this column says Yes and the application files are deleted from the Pen at the end of the Send Stored Files to PC operation. When off, this column says No and the application files on the Pen are not deleted.

Host Application

If a host application is set, its name will appear here; if none is set, None will appear. A host application is a PC application – other than the QuickLink-Pen Elite Desktop application – to which the stored files can also be transferred. This way you can view the sent stored data in these applications, in addition to viewing it in the Desktop application. See Activating Host Settings on page 54 for information on

53

Page 54

QuickLink-Pen® Elite Operation Manual activating the possibility of involving Host Applications in the send process, since, by default, this feature is turned off.

Pen Name

The name of the current Pen Name (the one whose data is currently displayed in the Desktop) is displayed in the Desktop bar. The Pen-PC File Transfer Settings dialog displays the setting for one “Pen Name”. When launching the Pen-PC File Transfer Settings dialog, the settings of the current Pen Name are displayed and its name appears again in the top left of the Pen-PC File Transfer Settings dialog. The Pen Name is a profile used in the Desktop for storing the data of one scanning device. When performing Pen-PC communications, such as Send Stored Files to PC, the Desktop matches the scanning device with its associated Pen Name, so that the data of one Pen is always stored in the associated Pen Name profile. Important: The Pen Name mechanism is for advanced users only, or users that own more than one actual scanning device. If you have one scanning device - it is highly advised to work with the default Pen Name “MyPen” – only.

Activating Host Settings

If you want the Pen to perform the Send Stored Files to PC with host applications, click the This Pen Name will Send Stored Files to host applications checkbox. Default host settings are set for each application and the Host Settings button is activated, allowing access to the Host Settings dialog. Note: Only one Pen Name can be designated at a time to interact with host applications. Again, as noted before, it is advised to work with the default Pen Name “MyPen”.

The Default Host Settings

The default host settings for each application are as following: • MS Word as the host for Scan and Store. • MS Outlook as the host for the Address Book. • MS Internet Explorer as the host for the Internet Explorer. • MS Excel as the host for Tables. • Note: there is no host application for the Image Capture application. Important: Any host applications you have set must be fully installed and functional on your PC, or else the Send Stored Files to PC function will fail. If you want to cancel the interaction of this product with host applications, simply uncheck This Pen Name will Send Stored Files to host applications checkbox. If you want to turn off the host interaction for some of the storing applications, but leave it on for others, refer to the explanation about the Host Application column, of the Host Settings dialog, on page 55.

The Host Settings Dialog

To change the host settings you have set, select the Host Settings button on the Pen-PC File Transfer Settings dialog to display the Host Settings child dialog. Note: if the Host Settings button is inactive, see Activating Host Settings on page 54 for information on activating it.

The dialog box displays a 4 column table in which the storing applications on your Pen and their host settings are listed. Following is a description of each column: Application Each row displays a different storing application which you have installed on your Pen and PC (this should be the same list viewed in the Pen-PC File Transfer Settings father dialog). Pen File The file(s) from each storing application that can be transferred to or from the host application, when performing the Send Stored Files to PC operation, are as follows: • Scan and Store: All Scan and Store files (*.qnt) are transferred to the host application. • Address Book: All addresses in the main Address Book file, mainadd.qad, are transferred to and/or from the host application. 54

Page 55

QuickLink-Pen® Elite Operation Manual •

Internet Links: All links in the main Internet Links file, mainlnk.qlk, are transferred to and/or from the files in the specified folder of the host application. • Tables: All Tables files (*.qtb) are transferred to the host application. Host Application The current host application set for the application. This option contains a list of available hosts for each application, plus the option None. Use the None option to turn off host application interaction for a specific application. Host Folder The folder in which the host application files, that are created or updated during the Send Stored Files to PC process, are stored. Note: Files sent, with a host application set, are placed in the folder specified in the Host Folder column, as well as in the QuickLink-Pen Elite Desktop installation folder.

Show this dialog before each Send Stored Files to PC

At the bottom of the Pen-PC File Transfer Settings dialog is a Show this dialog before each file transfer check box. Checked is on, not checked is off (the default). Click the option to toggle the check mark. When this option is on, this dialog will appear right after selecting the Send Stored Files to PC on the Pen, prior to actually starting the process. This way you can confirm that the settings are satisfactory. If they are not satisfactory, you can change them. When done, press Proceed from the Pen-PC File Transfer Settings dialog, to continue the send process, or press Close to stop the process. Following are instructions on changing the Pen-PC File Transfer Settings and/or the Host Settings for each of the storing applications.

File Transfer Settings for Scan and Store

The Send Stored Files to PC operation is performed according to the settings set in the Pen-PC File Transfer Settings dialog (and its child dialog Host Settings).

Changing the Mode or Flush Settings

1. 2. 3. 4. 5.

Access the Pen-PC File Transfer Settings dialog. Select the Scan and Store row from the table. Click on the Change button. The Change Pen-PC File Transfer Settings dialog appears. From the Transfer Mode section, click on the desired mode to activate its radio button: • Pen to PC (the default) will set that the stored text files from your Pen will be copied from the Pen to the PC. • Don’t send the stored files of this application – when selecting this option, the Send Stored Files to PC does not include the Scan and Store application, or its files and no changes are performed not on the Pen nor in the PC (Desktop or Host Applications). 6. In the right side of the Change Pen-PC File Transfer Settings dialog, click on the Flush check box to set the Flush mode. Checked is on (the default), not checked is off. When on, this option will cause the Scan and Store files on the Pen to be deleted after they are sent to the PC when performing Send Stored Files to PC.

Changing the Host Application Settings

1. Make sure that the This Pen Name will Send Stored Files to host applications check box on the PenPC File Transfer Settings dialog is checked and click the Host Settings button. Note: if the Host Settings button is inactive, see Activating Host Settings on page 54 for information on activating it. 2. The Host Settings dialog appears. 3. Select the Scan and Store row from the table. 4. Click on the application name field (under the Host Application column). 5. Choose the desired setting from the list that opens: • Word – the stored pen files of this application are converted to .doc format and placed in the folder specified in the Host Folder column. You can access this folder with MS Explorer and double-click any of the files. The files will open in MS Word (if installed on your PC). Outlook– the stored pen files of this application are converted to the Outlook Notes format and placed • in the MS Outlook Notes folder, as specified in the Host Folder column. None – select this option to cancel any host interaction with the Scan and Store application. • 6. Click OK to save changes and close the Host Settings dialog. Click Cancel to disregard any settings you have just changed.

File Transfer Settings for Image Capture

The Send Stored Files to PC operation is performed according to the settings set in the Pen-PC File Transfer Settings dialog (and its child dialog Host Settings).

Changing the Mode or Flush Settings

1. Access the Pen-PC File Transfer Settings dialog. 55

Page 56

QuickLink-Pen® Elite Operation Manual 2. 3. 4. 5.

Select the Image Capture row from the table. Click on the Change button. The Change Pen-PC File Transfer Settings dialog appears. From the Transfer Mode section, click on the desired mode to activate its radio button: • Pen to PC (the default) will result in the stored image files from your Pen being copied from the Pen to the Desktop. • Don’t send the stored files of this application – when selecting this option, the Send Stored Files to PC does not include the Image Capture application, or its files and no changes are performed - not on the Pen, nor in the Desktop. 6. In the right side of the Change Pen-PC File Transfer Settings dialog, click on the Flush check box to set the Flush mode. Checked is on (the default), not checked is off. When on, this option will cause the Image Capture files on the Pen to be deleted after they are sent to the Desktop, when performing Send Stored Files to PC.

Changing the Host Application Settings

There are no host applications for this application. The .bmp files from the Pen are transferred and displayed in the Desktop. Click on the file name once to display it in the Desktop window, double-click on the file name to open it in the graphic editor or viewer you have associated .bmp files with, in the Windows settings of your PC.

File Transfer Settings for Address Book

Important: This is an add-on application that is not included in your default product. To use it, you must first add it to your Pen and Desktop application, using the CD-ROM (see Installing Add-On Applications on page 35). The Send Stored Files to PC operation is performed according to the settings set in the Pen-PC File Transfer Settings dialog (and its child dialog Host Settings).

Changing the Mode or Flush Settings

1. 2. 3. 4. 5.

Access the Pen-PC File Transfer Settings dialog. Select the Address Book row from the table. Click on the Change button. The Change Pen-PC File Transfer Settings dialog appears. From the Transfer Mode section, click on the desired mode to activate its radio button: • Synchronize Pen and PC (the default) - all addresses from the main Address Book (mainadd) – those stored in the Pen and those created or modified in the PC (Desktop and Host Application) - are synchronized - resulting in one Address Book file (mainadd), identical on the Pen, on the Desktop and in the Host application (if one is set). • PC to Pen will result in the address book files, existing in the Address Book application of the Desktop, being copied to the Pen (overwriting the ones on the Pen). • Don’t send the stored files of this application – when selecting this option, the Send Stored Files to PC does not include the Address Book application, or its files and no changes are performed - not on the Pen, nor in the PC (Desktop or Host Applications). 6. In the right side of the Change Pen-PC File Transfer Settings dialog, click on the Flush check box to set the Flush mode. Checked is on, not checked is off (the default). When on, this option will cause the Address Book files on the Pen to be deleted after they are sent to the PC, when performing Send Stored Files to PC.

Changing the Host Application Settings

1. Make sure that the This Pen Name will Send Stored Files to host applications check box on the PenPC File Transfer Settings dialog is checked and click the Host Settings button. Note: if the Host Settings button is inactive, see Activating Host Settings on page 54 for information on activating it. 2. The Host Settings dialog appears. 3. Select the Address Book row from the table. 4. Click on the application name field (under the Host Application column). 5. Choose the desired setting from the list that opens: Outlook– the addresses from the mainadd file are converted to the Outlook Contacts format and • placed in the MS Outlook Contacts folder, as specified in the Host Folder column. None – select this option to cancel any host interaction with the Address Book application. • 6. Click OK to save changes and close the Host Settings dialog. Click Cancel to disregard any settings you have just changed.

File Transfer Settings for Internet Links

Important: This is an add-on application that is not included in your default product. To use it, you must first add it to your Pen Desktop application, using the CD-ROM (see Installing Add-On Applications on page 35).

56

Page 57

QuickLink-Pen® Elite Operation Manual

Changing the Mode or Flush Settings

1. 2. 3. 4. 5.

Access the Pen-PC File Transfer Settings dialog. Select the Internet Links row from the table. Click on the Change button. The Change Pen-PC File Transfer Settings dialog appears. From the Transfer Mode section, click on the desired mode to activate its radio button: • Synchronize Pen and PC (the default) - all links from the main Internet Links file (mainlnk), those stored in the Pen and those created or modified in the PC (Desktop and Host Application) - are synchronized - resulting in one Internet Links file (mainlnk), identical on the Pen, on the Desktop and in the Host application (if one is set). • PC to Pen will result in the internet links files, existing in the Internet Links application of the Desktop, being copied to the Pen (overwriting the ones on the Pen). • Don’t send the stored files of this application – when selecting this option, the Send Stored Files to PC does not include the Internet Links application, or its files and no changes are performed - not on the Pen, nor in the PC (Desktop or Host Applications). 6. In the right side of the Change Pen-PC File Transfer Settings dialog, click on the Flush check box to set the Flush mode. Checked is on, not checked is off (the default). When on, this option will cause the Internet Links files on the Pen to be deleted after they are sent to the PC, when performing Send Stored Files to PC.

Changing the Host Application Settings

1. Make sure that the This Pen Name will Send Stored Files to host applications check box on the PenPC File Transfer Settings dialog is checked and click the Host Settings button. Note: if the Host Settings button is inactive, see Activating Host Settings on page 54 for information on activating it. 2. The Host Settings dialog appears. 3. Select the Internet Links row from the table. 4. Click on the application name field (under the Host Application column). 5. Choose the desired setting from the list that opens: Internet Explorer – the links from the mainlnk file are placed in the Favorites folder of MS Internet • Explorer, under a sub folder, as specified in the Host Folder column. Netscape – the links from the mainlnk file are converted into Netscape Bookmarks, under a sub • folder, as specified in the Host Folder column. Note: If you select Netscape and Netscape has more than one user profile, you are prompted to select the Netscape user profile under which you would like your links to be saved as bookmarks. Netscape must be updated to its latest version in order to be compatible with the Pen. None – select this option to cancel any host interaction with the Internet Links application. • 6. Click OK to save changes and close the Host Settings dialog. Click Cancel to disregard any settings you have just changed.

File Transfer Settings for Tables

Important: This is an add-on application that is not included in your default product. To use it, you must first add it to your Pen and Desktop application, using the CD-ROM (see Installing Add-On Applications on page 35). The Send Stored Files to PC operation is performed according to the settings set in the Pen-PC File Transfer Settings dialog (and its child dialog Host Settings).

Changing the Mode or Flush Settings

1. 2. 3. 4. 5.

Access the Pen-PC File Transfer Settings dialog. Select the Tables row from the table. Click on the Change button. The Change Pen-PC File Transfer Settings dialog appears. From the Transfer Mode section, click on the desired mode to activate its radio button: • Pen to PC (the default) will result in the stored table files from your Pen, being copied from the Pen to the PC. • Don’t send the stored files of this application – when selecting this option, the Send Stored Files to PC does not include the Tables application, or its files and no changes are performed - not on the Pen, nor in the PC (Desktop or Host Applications). 6. In the right side of the Change Pen-PC File Transfer Settings dialog, click on the Flush check box to set the Flush mode. Checked is on (the default), not checked is off. When on, this option will cause the Tables files on the Pen to be deleted after they are sent to the PC, when performing Send Stored Files to PC.

57

Page 58

QuickLink-Pen® Elite Operation Manual

Changing the Host Application Settings

1. Make sure that the This Pen Name will Send Stored Files to host applications check box on the PenPC File Transfer Settings dialog is checked and click the Host Settings button. Note: if the Host Settings button is inactive, see Activating Host Settings on page 54 for information on activating it. 2. The Host Settings dialog appears. 3. Select the Tables row from the table. 4. Click on the application name field (under the Host Application column). 5. Choose the desired setting from the list that opens: Excel – the stored pen files of this application are converted to .xls format and placed in the folder • specified in the Host Folder column. You can access this folder using MS Explorer and double-click any of the files. The files will open in MS Excel. None – select this option to cancel any host interaction with the Scan and Store application. • 6. Click OK to save the changes and close the Host Settings dialog. Click Cancel to disregard any settings you have just changed.

Confirming Pen-PC Communications

1. Connect the Pen to the PC. Make sure the connection is done in the same manner you had chosen during the Set Up Product on PC procedure of the QuickLink-Pen® Elite CD-ROM. For example, make sure that the USB plug side of the USB cable is connected to the USB outlet on your PC and that the other side of the cable is connected to the PC-Link Connector outlet of your Pen. 2. In the Desktop application, make sure that the Pen Communications are ON (this is the default).

How to know if Pen Communications are on

To find this out, simply confirm that the Pen Communications icon in the Desktop is pressed ) and that the first option in the Pen Communications menu in the Desktop bar is ( Turn Pen Communications off. If the option says Turn Pen Communications On, select this option to turn the Pen Communications on. • The Desktop cannot detect communications from the Pen when Pen Communications are off, when the Pen is not connected properly, or when the necessary software is not working. • When Pen communications are on, the communications port is busy (you can see which one in the Communications Settings dialog of the Desktop). You cannot use this port simultaneously for any other purpose unless you exit the Desktop application. 3. If you fail to set the Pen Communications on, rerun the Set Up Product on PC procedure from the CDROM. This may fix the problem. If not, feel free to contact our Support Team (see Contact and Support Information on page 6).

Sending the Stored Files

1. Turn the Pen on. until you reach the Pen Main Menu. 2. Long press 3. Press until Send Stored Files to PC appears on the screen.

4. Press . The sending process begins – the Pen displays Sending… and the PC shows a box with flying papers. If the process does not begin or the Pen reports Sending… Connection failed, please refer to Confirming Pen-PC Communications on page 58. 5. When the process is done, OK the pop up in the QuickLink-Pen Elite Desktop. 6. The data of the applications appears in the Pen, Desktop and Host applications – all according to the settings you have set in the Pen-PC File Transfer Settings dialog (see Setting the File Transfer Settings on page 52).

Viewing and Editing on the PC

1. Start the Desktop application (See Starting the Desktop Application on page 52). 2. Confirm that the desired Pen Name is the current one, so that its files are displayed in the Desktop. The current Pen Name is displayed in the desktop icon bar, for example: Note: The Pen Name is a profile used in the Desktop for storing the data of one scanning device. So, if you own one scanning device, it is highly advised to work with only one Pen Name – the default Pen Name “MyPen”. 3. Click on the icon of the desired application, from the left pane of the Desktop.

58