The text of a manual · part 5 of 5
BT-700 Barcode Tagger 700 Control Unit User's Guide, pages 41 to 46
Pages 41 to 46 of 46
The original document is the PDF (761 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Whittier BT-700
Page 41
TJF Sample One: WMP Tagger Job File Format Jan 2001 Lightblue Smuff ================================================= # no comments may appear before this point # the top three lines of the file identify it # as a job file and the name of the job # Format = Tray Tag Printer = Yes # Format = {Tray, T ray Fill In, Sack, Sack Fill In } # Printer = {Yes, No } # Act Printer = Yes # designates this as an ACT job # optional # Origin Line = Whittier Mailing Service # text or "<Standard>" # required # Point of Entry = 906 # ##### if Origin line is <Standard>, otherwise ### # required # Mailer Code = # text # optional, ignored if Origin Line is not <Standard> # Category = A0101 # @####, must be a valid category consisting of a single letter # class code, a two-digit process category code, and a two-digit # sortation code # required ================================================= # <subtype>, <ZIP>, <quantity> # <subtype> consists of a single digit number describing the length # of <ZIP> followed by a two-digit tray type code, optionally # followed by one more digit to indicate the specific choice of # address where there are choices, such as APO or APO/FPO. # the number of digits of <ZIP> that will be looked at is # based on <subtype>, extra digits on the end MUST be zeros # and will be ignored. For example, 90700 and 4350000 are # valid 3 Digit ZIP codes. # this list currently limited to 1000 entries 004, 0, 1 333, 342, 1 550, 90632, 1 333, 982, 2 333, 966, 1 =================================================
Page 42
TJF Sample Two:
WMP Tagger Job File Format July97
STDA/LTRS/ECR
Format = Tray
Tag Printer = Yes
Act Printer = No
Origin Line = <Standard> Point of Entry = 90605 Mailer Code =
Category = C0101
962, 90502B023, 1 561, 90605, 1 561, 23421, 1 561, 23423, 3
TJF Sample Three:
WMP Tagger Job File Format July97 ACT
Format = Tray
Tag Printer = Yes
Act Printer = Yes
Origin Line = <Standard> Point of Entry = 90605 Mailer Code =
Category = C0102
334, 234, 1
550, 00000, 1
334, 234, 1
Page 43
Appendix B USING THE FTP OPTIONS OF THE BT700 Requirements: 1. A Local Area Network running TCP/IP protocol with FTP server. 2. The IP address of the FTP server. 3. The default gateway IP address of the LAN. 4. A valid static IP address assigned to the BT700. 5. A user id and password that the FTP server will recognize and that the BT700 can use. Must be upper case letters and numbers only.
Instructions: 1. Connect network cable to the BT700. 2. Go to Net work Settings from the System Fun ctions menu and enter the static IP for th e BT700 [2] Tagger IP Address and the default gatew ay [3] Gateway IP Address. Select [5] Apply settings and let the Taggers system reboot.
Network Settings 1) Network Connection 2) Tagger IP Address 3) Gateway IP Address
(enabled) (192.168.1.125) (192.168.1.1)
5) Apply settings and reboot 6) Discard changes
3. On your network, copy WMP job files (*.tjf), Mail.dat files, or other tag files, to a directory that can be accessed using the FTP server. 4. In Job or Raw data Mode go to Ftp Login Information, enter [3] the FTP server's IP address, and [4] the Tagger system's user id and [5] password. Ftp Login 1) Connect 2) Network settings (enabled) 3) Server IP Address (192.168.1.22) 4) User ID (WHITTIER) 5) Password (WHITTIER) 6) Export log file to floppy
Page 44
5. Press [1] to initiate connection.
Page 45
Appendix C CLASS, TYPE, SORTATION, SUBTYPE CODES CLASS A First Class B Periodicals C Standard D Package Services F News TYPE 01 Letters 03 Flats 04 Machinable 05 Irregular 07 Commingled Irregular 08 Parcels 13 Drop Shipment SORTATION 01 Nonautomated 02 Automated 03 Regular 14 DBMC Rate 15 Bound Printed Matter 16 Media Mail 17 Machinable 18 Presorted 20 Priority Drop Shipment 21 Manual 22 Express Drop Shipment 23 Merged 24 Barcoded
SUBTYPE 000 Fill-In 002 Mixed AADC 004 Mixed ADC 010 Mixed BMC 012 Mixed AADC at BMC 014 Mixed ADC at BMC 320 3-Digit 321 3-Digit / 3-Digit Scheme 330 SCF 333 ADC 334 AADC 338 Destination ASF 339 Destination BMC 366 3-Digit Carrier Routes 550 5-Digit 555 5-Digit Mach and Irreg 556 5-Digit Scheme 561 5-Digit Carrier Routes 567 5-Digit Scheme Carrier Routes 568 Merged 5-Digit 569 Merged 5-Digit Scheme 960 Carrier Route 962 Basic Carrier Route 963 High Density Walk Sequence 964 Saturation Walk Sequence
Page 46
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 o f the FCC Rules. Th ese limits are designed to p rovide reasonable p rotection against harmful interferen ce when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequen cy energy and, if not installed and used in accordan ce with th e instru ction manual, may cause harmful interferen ce to radio communications. Op eration of this equipment in a residential area is likely to cause harmful interferen ce in which case th e user will be required to co rrect th e interferen ce at his own expense. Updated 2/2/02