EIPScan Setup This procedure is for the EIPScan simulation tool published by Pyramid Solutions. 1. Right-click on “EIPScan Test Tool”, select “Add Device”:
2. Set the “IP Address” to match FIS-6801:
FIS-6801 Industrial Scanner User’s Manual
A-113
Page 442
Allen-Bradley PLC Setup FIS-6801 will show up in the main window:
3. Right-click on FIS-6801, select “Add Class1 Connection”:
A-114
FIS-6801 Industrial Scanner User’s Manual
Page 443
Appendices 4. When the “Add Class1 Connection” dialog pops up, select “Data Size”. 5. Populate “Originator->Target” (OUT) with 12, and “Target->Originator” (Big IN) with 176:
Alternately, “Target->Originator” could be set to 84 for the Small IN assembly. 6. Select “Rate”, and set packet rate to 20 milliseconds in both directions:
FIS-6801 Industrial Scanner User’s Manual
A-115
Page 444
Allen-Bradley PLC Setup 7. Select “Destination”. 8. Populate “Originator->Target” (OUT) with 198, and “Target->Originator” (Big IN) 101:
Alternately, “Target->Originator” could be set to 100 for the Small IN assembly. 9. Click OK, and the io data windows will show up in the main area, below FIS-6801. 10. In the I/O menu, select “Run mode” so that there is a check mark next to it:
A-116
FIS-6801 Industrial Scanner User’s Manual
Page 445
Appendices EIPScan begins polling the unit, and displays the content of the IN (blue) and OUT (green) assemblies:
The order of data displayed in each assembly block corresponds to the object model documentation. For a quick test, we can simulate the PLC setting the “User Tag”, and FIS-6801 echoing it back. 11. Click on the first byte (User Tag) in the green area (OUT):
FIS-6801 Industrial Scanner User’s Manual
A-117
Page 446
Allen-Bradley PLC Setup 12. Change the first byte to non-zero. The first byte (User Tag echo) in the blue area (IN) will change to the same value:
In fact, all bytes in the green OUT area will be echoed back in the blue IN area, at the same location relative to the beginning of the assemblies. Each byte, and bit, has a unique purpose. Please consult the object model for a description. Note that all data is displayed
A-118
FIS-6801 Industrial Scanner User’s Manual
Page 447
Appendices in little-endian order.
BS EIPScan - EIPscan qxhawk eiptest1 asm1025bi file View Request I/O Stack Device /10 Module Help
Os © on +] ElPScan Test Tool Network Path |10.10.5.234 ‘Adapter 10.10.4.130 + Request (all fields are in hex) Host 10.10.4130 Predefined: [(None) S QX HAWK - Connection Instance 1, RPIs 20/20, Oyclic eee Service hex) [@ Class then) [4, s biunenwee?es 43 SCSceeee eee ce Instance hex) [301 Attibute (hex) [2 10.105.234 Member thex) [ smbolteg [OO
Request Data, Each byte is @ 2 char hex value, separated by a space ie. 0a 26 19)
User Tag
Output control
Ext. In Ext Out Trigger count
Response Response Size (decimal) |260 5 00 GO OO 00 00 00 OO OO 00 00 GO GO OO 00 00 0D OO 00 00 00 00 OO 00 01 00 OO OO 01 00 00 OO O1 00 00 00 00 OO OO a 00 00 00 00 00 32 33 34 35 36 37 38 39 30 31 32 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SO etch oe ogf60 00 00 9F 00 00 G0 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 101 00.00 00 G1 00:00 00 00 00 00 00 09 92> } 9 6 ooo” by 00 00 GO OO OD OO 0D OO 00 OD OO 0D OD OO 00 00 00 OD OO 00 OO 00 00 O80 00 O80 00 00 Noread 00 00 00 00 00 00 00 00 00 count <D]\ucMm {J >
‘Sent API 20.01 msec, Revd pkts 5535, Sent pkts 7012
Y 5 A msec, R Sent API 20.01 msec, Revd pkts 164265, Sent pkts 208135
4 Connection closed with Instance 1
, y msec, 1 msec, Rev API 25,35 msec, Sent API 20.01 msec, Revd pkts 24216, Sent pkts 30683 Connection closed with Instance 1 Connection opened with Instance 1, Max Recv Delay 102 msec, Max Send Delay 6 msec, Rev API 25.35 msec, Sent API 20.01 msec, Revd pkts 119098, Sent pkts 150917 Error: Request Failed: Target is not responding Error: Request Failed: Target is not responding
37 Open Connection failed for Instance 1: Invalid Segment Type or Segment Value in Path 18:20:45:53, Connartion clced with Inctance 1 ¥ 1 Classi connections active, Max Recy Delay 102 msec, Max Send Delay 6 msec, Max Recv API 25.35, Max Send API 20.01
FIS-6801 Industrial Scanner User’s Manual A-119
Page 448
Interface Standards
Appendix K, Interface Standards Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. In the FIS-6801, selection of interface is made by pin assignment and, in the case of host communication, by software switching between RS-232 and RS-422/RS-485.
RS-232 RS-232 defines an interface between two devices such as, for example, the Scanner and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (19.7m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.
RS-422/RS-485 RS-422, unlike RS-232, measures signals deferentially; that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1219m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line and must have a common ground. It can be used wherever RS-232 is used.
Ethernet TCP/IP and EtherNet/IP TCP/IP and EtherNet/IP protocols are supported over Ethernet. A 6-byte hardware address is used, which is divided into a 3-byte vendor ID and a 3-byte vendor-defined field. Ethernet-enabled device manufacturers are assigned a unique vendor ID, and are then responsible for insuring that all of their devices have unique addresses in the last 3 bytes.
A-120
FIS-6801 Industrial Scanner User’s Manual
Page 449
Appendices
Appendix L, Glossary of Terms Aberration, The failure of an optical lens to produce an exact point-to-point correspondence between the object and its resulting image. Various types are chromatic, spherical, coma, astigmatism and distortion. Absorption, The loss of light of certain wavelengths as it passes through a material and is converted to heat or other forms of energy. (–) Active Illumination, Lighting an area with a light source coordinated with the acquisition of an image. Strobed flash tubes and pulsed lasers are examples. ADC, See Analog-to-Digital Converter. A/D Converter, See Analog-to-Digital Converter. AGC, See Automatic Gain Control. Ambient Light, Light which is present in the environment of the imaging front end of a vision system and generated from outside sources. This light, unless used for actual illumination, will be treated as background Noise by the vision system. Analog, A smooth, continuous voltage or current signal or function whose magnitude (value) is the information. Analog-to-Digital Converter (A/D Converter or ADC), A device that converts an analog voltage or current signal to a discrete series of digitally encoded numbers (signal) for computer processing. Application-Specific Integrated Circuit (ASIC), An integrated circuit that is customized for a particular kind of use, rather than general use. All vision system elements including firmware can be integrated into one ASIC. Architecture, The hardware organization of a vision system designed for high speed image analysis. ASIC, See Application-Specific Integrated Circuit. Aspect Ratio, The ratio between the height and width of a sensor or display. Found by dividing the vertical number of pixels (height) by the horizontal number of pixels (width) leaving it in fractional format. Automatic Gain Control (AGC), Adjustment to signal strength that seeks to maintain a constant level regardless of the distance between a reader and symbol. Auxiliary Port, RS-232 connection to an auxiliary terminal or device for remote viewing. Blooming, A situation in which too many photons are being produced to be received by a pixel. The pixel overflows and causes the photons to go to adjacent pixels. Blooming is similar to overexposure in film photography, except that in digital imaging, the result is a number of vertical and/or horizontal streaks appearing from the light source in the picture. Baud Rate, The number of discrete signal events per second; bits per second. Capture, The act of acquiring and storing video images in an Scanner or host computer. Also, the image captured. CCD, See Charge-Coupled Device.
FIS-6801 Industrial Scanner User’s Manual
A-121
Page 450
Glossary of Terms Charge-Coupled Device (CCD), A semiconductor device with an array of light-sensitive elements that converts light images into electrical signals. Check Character, A Modulus 43 or Modulus 10 character that is added to encoded symbol data for additional data integrity. CMOS, See Complementary Metal Oxide Semiconductor. Complementary Metal Oxide Semiconductor (CMOS), Like CCDs, CMOS Scanners include an array of photo-sensitive diodes, one diode within each pixel. Unlike CCDs, however, each pixel in a CMOS Scanner has its own individual amplifier integrated inside. Connector, A plug or socket on a device or cable providing in/out connectivity for various circuits and pins. Concentrator, Intermediary device that relays data from Scanners to a host and commands from the host to the Scanners or other devices. Counter, Memory space allocated to keep track of Scanner events. DAC, See Digital-to-Analog Converter. Daisy Chain, Linkage of primary and secondary Scanners allowing data to be relayed up to the host via auxiliary port connections. Decode, A Good Read. The successful interpretation and output of the information encoded in a symbol. Default, Restores ROM or flash settings, initializes serial commands and resets all counters. Delimited, A delimited command or field is bracketed by predefined characters. Decode Rate, The number of good reads per second ahieved by an Scanner. Darkfield Illumination, Lighting of objects, surfaces, or particles at very shallow or low angles, so that light does not directly enter a reader’s optical hardware. Depth-of-Field, The in-focus range of an imaging system. Measured from the distance behind an object to the distance in front of the object with all objects appearing in focus. Diffused Lighting, Scattered soft lighting from a wide variety of angles used to eliminate shadows and specular glints from profiled, highly reflective surfaces. Digital-to-Analog Converter (DAC), A VLSI circuit used to convert digitally processed images to analog for display on a monitor. Digital Imaging, Conversion of an image into pixels by means of an Analog-to-Digital Converter where the level of each pixel can be stored digitally. Digital Signal Processor (DSP), A VLSI chip designed for ultra-high-speed arithmetic processing. Often imbedded in a vision engine. Discrete I/O, Inputs and outputs characterized by discrete signal transitions from one voltage level to another so that digital switching can occur. Direct Memory Access (DMA), A capability provided by some computer bus architectures that allows data to be sent directly to memory from an attached device. DMA, See Direct Memory Access. DSP, See Digital Signal Processor. Dynamic Range, The difference between the minimum and maximum thresholds of discernible images; the amount of usable signal. A-122
FIS-6801 Industrial Scanner User’s Manual