The text of a manual · part 44 of 46
FIS-6801 Industrial Scanner User's Manual, pages 431 to 440
Pages 431 to 440 of 454
The original document is the PDF (7.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-6801
Page 431
Appendices 7. Double-click on the “Controller Tags” item, and verify FIS-6801’s :I and :O tags appear in the Controller Tags window:
8. Open the “Main Routine”:
FIS-6801 Industrial Scanner User’s Manual
A-103
Page 432
Allen-Bradley PLC Setup 9. Right-click on the top rung and select “Import Rung”:
10. Navigate to the “32-000001-xx.L5X” file and click “Import”:
A-104
FIS-6801 Industrial Scanner User’s Manual
Page 433
Appendices 11. At the “Import Configuration” window, link the first two items to the module name assigned earlier:
12. Link “:I” to the input assembly:
FIS-6801 Industrial Scanner User’s Manual
A-105
Page 434
Allen-Bradley PLC Setup 13. Link “:O” to the output assembly:
14. Delete any empty rungs:
A-106
FIS-6801 Industrial Scanner User’s Manual
Page 435
Appendices 15. Select one CPS instruction per rung, the “_small_pt” on the left, or the “_big_pt” on the right. Keep the one that corresponds to the assembly sizes configured for the module, and delete the other:
FIS-6801 Industrial Scanner User’s Manual
A-107
Page 436
Allen-Bradley PLC Setup 16. In this example, the small assembly set has been kept:
In this example, the big assembly set has been kept:
For the remainder of this document, the big assembly set is demonstrated. The system is now configured enough to test communication with FIS-6801. A-108
FIS-6801 Industrial Scanner User’s Manual
Page 437
Appendices 17. Select the control button next to “Offline”, and select “Download”:
18. Once the program has downloaded, make sure the PLC is in Run Mode:
FIS-6801 Industrial Scanner User’s Manual
A-109
Page 438
Allen-Bradley PLC Setup 19. To open the Program Tags, right-click on “Program Tags” and select “Monitor Tags”:
20. Expand the “FIS-6801Hawk_IO_big_pt” so that the .IN and .OUT structures and values are visible:
A-110
FIS-6801 Industrial Scanner User’s Manual
Page 439
Appendices 21. Change the “.OUT.usertag” to non-zero:
FIS-6801 Industrial Scanner User’s Manual
A-111
Page 440
Allen-Bradley PLC Setup The “.IN.usertag_echo” will change to match the same value as the “.OUT.usertag”:
This confirms that two-way communication with FIS-6801 is successful. It is left to the programmer to move or modify the CPS instructions in the Main Program according to the application’s requirements. Operation of the data fields within the assemblies is described in the object model documentation.
A-112
FIS-6801 Industrial Scanner User’s Manual