The text of a manual · part 13 of 46
FIS-6801 Industrial Scanner User's Manual, pages 121 to 130
Pages 121 to 130 of 454
The original document is the PDF (7.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-6801
Page 121
Parameters
Gateway Enter the Gateway address of the Scanner in this field.
FIS-6801 Industrial Scanner User’s Manual
5-19
Page 122
Communication
IP Address Mode Determines how the Scanner’s IP address will be defined.
Static In Static Mode, the Scanner uses the user-defined IP address entered in ESP.
DHCP In DHCP Mode, the Scanner automatically acquires the IP address, Subnet, and Gateway addresses from a DHCP or BOOTP server.
5-20
FIS-6801 Industrial Scanner User’s Manual
Page 123
Parameters
TCP Port 1 One of two TCP ports for Ethernet communication with the Scanner. The default setting is 2001.
Symbol Data Output Enables or disables decoded symbol data output from the Scanner.
Extra Symbol Information Enables or disables extra symbol information output from the Scanner.
Diagnostics Output Enables or disables diagnostics output from the Scanner.
External Source Processing Mode Enables or disables processing of commands or data from sources external to the Scanner. Command Command enables command processing in the Scanner. Data Data enables Ethernet TCP Port 1 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.
FIS-6801 Industrial Scanner User’s Manual
5-21
Page 124
Communication
TCP Port 2 One of two TCP ports for Ethernet communication with the Scanner. The default setting is 2003.
Symbol Data Output Enables or disables decoded symbol data output from the Scanner.
Extra Symbol Information Enables or disables extra symbol information output from the Scanner.
Diagnostics Output Enables or disables diagnostics output from the Scanner.
External Source Processing Mode Enables or disables processing of commands or data from sources external to the Scanner. Command Command enables command processing in the Scanner. Data Data enables Ethernet TCP Port 2 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.
5-22
FIS-6801 Industrial Scanner User’s Manual
Page 125
Parameters
Search and Configure Mode
Search and Configure Mode is intended primarily for initial setup of a FIS-6801 in a network. This parameter controls whether or not the FIS-6801 will respond to ESP’s Search function in the Ethernet TCP/IP connect dialog section of the Connection Wizard:
After the FIS-6801 is in full use in an application, you may want the Scanner to continue to appear in the Search response list for future searches. This can help prevent disruption of the system that may occur is ESP were to show only unconfigured units.
Changes to this parameter are saved to NOVRAM and are set to default on power on. A Reset <A> is required for settings to take effect. Important: Once this setting is Disabled, ESP will only be able to connect to the Scanner if you know the IP address and enter it in the IP Address field of the Ethernet TCP/IP connect dialog. Search and Configure Mode can be re-enabled by defaulting the FIS-6801.
Enabled When enabled, Search and Configure Mode will find the Scanner and settings can be changed.
Timed Window When Timed Window is selected, Search and Configure Mode will find the Scanner and settings can be changed, but only 60 seconds from the last reset. After 60 seconds, Search and Configure Mode will be disabled.
FIS-6801 Industrial Scanner User’s Manual
5-23
Page 126
Communication
Protocol Selection In general, the point-to-point protocols will work well in most applications. They require no address and must use RS-232 or RS-422 communication standards. Protocols define the sequence and format in which information is transferred between the Scanner and the host, or in the case of Multidrop, between the Scanners and a concentrator. Note: In all protocol modes, the Preamble and Postamble character strings can be used to frame the decoded data, and both are included in calculating the LRC (Longitudinal Redundancy Check).
5-24
FIS-6801 Industrial Scanner User’s Manual
Page 127
Parameters
Protocol Options
Point-to-Point (Standard) Used only with RS-232 or RS-422. Standard Point-to-Point requires no address and sends the data to the host whenever it is available, without a request or handshake from the host.
Point-to-Point with RTS/CTS A scanner initiates a data transfer with an RTS (request-to-send) transmission. The host, when ready, responds with a CTS (clear-to-send) and the data is transmitted. RTS and CTS signals are transmitted over two dedicated wires as defined in the RS-232 standard. Used only with RS-232. Point-to-Point with RTS/CTS (request-to-send/clear-to-send) is a simple hardware handshake protocol that allows a scanner to initiate data transfers to the host.
Point-to-Point with XON/XOFF If an XOFF has been received from the host, data will not be sent to the host until the host sends an XON. During the XOFF phase, the host is free to carry on other chores and accept data from other devices. Used only with RS-232. This option enables the host to send the XON and XOFF command as a single byte transmission command of start (^Q) or stop (^S).
Point-to-Point with RTS/CTS and XON/XOFF Used only with RS-232. This option is a combination of Point-to-Point with RTS/CTS and Point-to-Point with XON/XOFF.
ACK/NAK See ACK / NAK Options.
Polling Mode See Polling Mode Options.
FIS-6801 Industrial Scanner User’s Manual
5-25
Page 128
Communication
Address The Protocol Address can be any number between 1 and 50.
Protocol Port RS-232 A or RS-422 can be used as Protocol Ports.
5-26
FIS-6801 Industrial Scanner User’s Manual
Page 129
Parameters
ACK / NAK Options These parameters take effect for ACK/NAK on the main RS-232 or RS-422 ports (not on the Auxiliary Port), and are completely independent of the Polling Mode Options. The Scanner always follows the protocol in both directions (to and from the host). There is no option to disable it from either direction.
RES-NAK Defaults RES: (Reset) REQ: (Request) STX: (Start of Text) ETX: (End of Text) ACK: (Acknowledge) NAK: (Negative Acknowledge)
FIS-6801 Industrial Scanner User’s Manual
NUL (0x00) NUL (0x00) NUL (0x00) NUL (0x00) ACK (0x06) NAK (0x15)
5-27
Page 130
Communication
ACK/NAK Protocol The following are general outlines of the ACK/NAK protocol. Items that are framed by brackets ( [ ] ) can either be disabled or enabled. LRC does not include STX, but it does include preamble, postamble, and ETX. Symbol Data Output TX to host: [STX] [preamble] SYMBOL DATA [postamble] [ETX] [LRC] Response from host: ACK/NAK. Sent when LRC, ETX, postamble, or timeout (waiting for more data) are detected (if REQ is disabled) depending on what is enabled. Commands from Host to Scanner TX to Scanner: [STX] <command> [ETX] [LRC] Response from Scanner: ACK/NAK. Sent when LRC, ETX, or command-ending angle bracket ‘>’ are received, depending on what is enabled. Command Response from Scanner to Host TX to host: [STX] [preamble] COMMAND RESPONSE DATA [postamble] [ETX] [LRC] Response from host: ACK/NAK. Sent when LRC, ETX, postamble, command-ending angle bracket ‘>’, or timeout (waiting for more data) are detected, depending on what is enabled. As with Polling Mode <K140,5>, the Scanner can optionally perform the REQ and RES event sequences in ACK/NAK mode. If the sender does not receive an ACK or NAK, it will send REQ to request such a response (if enabled). When the sender receives an ACK, too many NAKs, or times out (if already enabled), it will send a RES (if enabled) to terminate the transaction. Note: See ACK/NAK Data Flow Examples in Appendix F for sample ACK/NAK communication scenarios.
5-28
FIS-6801 Industrial Scanner User’s Manual